luminaire
-
Product
General Lighting & Luminaire Goniophotometers
-
Photometric Solutions International Pty Ltd
These are Type C/gamma goniophotometers with wide-ranging applications including luminaires, floodlights, streetlights, LED clusters, emergency lighting, flat panel displays and others. These goniophotometers typically have an angular accuracy of better than 0.1°, which is perfect for LED and luminaire goniophotometry. The control software that comes with each system has advanced functions that make testing easy – even for inexperienced users. Additionally, the report generator and other software utilities that are also supplied make these systems powerful and advanced research and development tools.
-
Product
High Precision Rotation Luminaire Goniospectroradiometer
LSG-1800BCCD
-
LSG-1800BCCD Goniospectroradiometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800BCCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
Product
Goniometer Systems
-
Our Goniometetric measurement systems are optimized to provide precise measurement of angle dependent spatial radiation properties of LED luminaires, lamps and other light-producing modules. Using a variety of photometric and spectroradiometric detector options, our goniometer systems achieve optical properties as a function of angle with accuracy, precision and speed.
-
Product
Safety
-
Test Equipment to verify Safety, Quality and Compliance characteristics of electro-technical products as required by national and international safety regulatory agencies. These equipment are used to check Electrical Wiring Accessories, Electrical Home Appliances, Industrial Luminaires, Motors and components or parts used in such products. Several of these safety test equipment are common to many standards and are required for routine 100% test purposes to ensure product safety.
-
Product
GO-2000 Goniophotometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
GO-2000 is a highly automated luminaire light distribution performance test system, mainly used for all kinds of indoor lamps, road lamps and floodlights ( add B-β test accessories) light distribution performance test, total luminous flux test and electrical parameters (voltage, current, power, power factor) measurement.
-
Product
Luminaire Testing
-
Product Safety Consulting Inc.
With the emergence of LED technologies, being part of the renewed energy scene requires knowledge of how to design products to meet consumer needs while passing even more stringent safety testing than ever before. Staying on top of the new testing requirements, from local and global standpoints, is what we do. Standards generally are not clear; they leave room for interpretation and often present constraints to product design. At PSC, we offer solutions to non-compliance rather than simply reporting a pass/no-pass statement. And, we communicate with straightforward explanations of safety issues that often arise during the testing process. Our expert product testing team understands what you need to do to achieve compliance. Failing at the testing stage only costs you valuable time and money. It allows the competition to beat you to the sale and takes resources away from future growth.
-
Product
Test Accessories
-
By combining the latest in LED technology with the unmatched illuminating dynamics of prismatic glass, this High Bay LED luminaire brings a superior, incomparable proficiency and reliability to the table. With its remote driver capability, the TDK HBLED-540 High Bay LED Light Fixture is ideal for EMC chambers with minimal RF emissions.
-
Product
Goniophotometer
GMS2000
-
In this goniophotometer, the tested luminaire rotates in the prescribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously. The combined motion of the luminaire and mirror permit luminous measurement at the direction of any horizontal or vertical angle without tilting the luminaire, therefore, the luminous intensity will be not variation. The photometer head located at a fixed position of the limiting photomet- ric distance in front of the reflecting mirror to gather the light in each direction.
-
Product
Ball Pressure Apparatus
BP-20
-
Is designed to perform tests specified in many standards where resistance of insulating materials to elevated operating temperatures is to be determined. It is used to test insulation materials used in Electrical Appliances, Electrical wiring accessories, luminaires, motors, connectors, etc. The test ensures that external parts of insulating material, the deterioration of which might cause the appliance to fail to comply with the relevant standards, are sufficiently resistant to heat.
-
Product
Salt Spray Chambers
-
Weice Testing Instrument Co.,Ltd.
The WTS series of salt spray chambers are manufactured and designed to meet the high quality requirements and standards, such as ISO, JIS, DIN, ASTM, IEC, GB and SAE. They are used to test the resistance capabilities of materials eroded by brine, these materials may be used in Electrical Appliances, Electrical Wire, Accessories, Luminaires etc.
-
Product
Spring Impact Hammer IK Level Tester
IK01-06
-
The most of luminaires manufactory were request to do IK level test (Impact Protection), LISUN can supply the IK test instrument. IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
Product
Power Over Ethernet (PoE)
-
Power over Ethernet (PoE) is a revolutionary technology that enables delivery of power over standard Ethernet infrastructure to facilitate quick and easy installation of WLAN access points, network cameras, IP telephones and other IP-based devices. The proliferation of Ethernet-connected devices such as Pan-Tilt-Zoom (PTZ) security cameras, 802.11ac and 802.11ax access points, LED luminaires and Internet of Things (IoT) appliances has created an unprecedented demand for more power. PoE is the key to efficiently, cost-effectively and reliably power network devices.
-
Product
Physical
-
This category covers test equipment for verification of resistance to heat, fire, tracking, mechanical stress, endurance, impact, force, torque, dimensional accuracy & similar related parameters as required by national and international safety regulatory agencies. These equipment are used to check Electrical WiringAccessories, Electrical Home Appliances, Industrial Luminaires, Motors and components or parts used in such products. Many of these test equipment are common to many standards and are essential for routine test purposes.
-
Product
Integrating Sphere Coating
SP-80
-
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. A good internal coating is essential forintegrating spheres. It is a special water based BariumSulphate (BaSO ) white reflective paint particularly suitablefor internal coating of Integrating Spheres. It offers an almost constant reflectance in the range of 380 nm to 780 nm (visible wavelength range).
-
Product
Safety Test Panel for Luminaire Fixture
-
SCR ELEKTRONIKS introduces Safety Test Panel for Luminaire with PC Datalogging. The tests are Performed as Prescribed in IS the Panel Carries out different tests one by one and provides indication of the Test results as OK or NOT-OK. It is very useful and handy in line testing on Mass production line as well as type Testing.
-
Product
CCD Spectroradiometer Integrating Sphere Compact System
LPCE-3
-
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.
-
Product
Goniophotometer
-
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
Product
Goniophotometer For Luminaries Intensity Distribution Curve
LCG-1800
-
Shenzhen Chuangxin Instruments Co., Ltd.
Mainly used to measure FL etc. When installing luminaires, the lighting center of luminare and the rotating center of rotating table shall be at the same position. In B- coordinates, luminaire axis is superposed with the horizontal axis of rotating table. In A- coordinates, luminaire axis is vertical with the horizontal axis of rotating table.
-
Product
Tumbling Barrel Apparatus
ME-999
-
Is specially designed and manufactured for use in laboratories involved in testing Appliances, Electrical Accessories, Luminaires and other related Electrotechnical products. It is used to perform the test specified in many standards to determine compliance with safety equirements, particularly mechanical strength of test samples.
-
Product
LED Driver (V4, V5, PWM, 18CH)
SLAMMO
-
When it comes to LED control, bigger IS better and the SLAMMO boasts class-leading capacity of up to 25Amps, 600W @24VDC (up to 450W in IP67 enclosures) / 300W at 12VDC. For constant current LEDs, the SLAMMO P can drive up to 96 luminaires equipped with PWM controlled CC drivers such as the Meanwell LDD series (350mA to 1.6A per LDD)
-
Product
Goniophotometers
-
Instrument Systems Optische Messtechnik GmbH
All goniophotometers are designed as Type C with a horizontal alignment of the optical axis (turning luminaire configuration). Each goniometer sets benchmarks in its class for precision, reliability and handling. If these goniophotometers are combined with a spectroradiometer from Instrument Systems, they are able to determine not only photometric data but also spectral quantities, such as color coordinates, color temperature, and even color rendering index as a function of angle.
-
Product
High Precision Rotation Luminaire Goniophotometer
LSG-1800B
-
LSG-1800B Goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
Product
Lighting Reliability
-
LED/OLED package lifetime is highly dependent on thermal management, and LED lamp performance can be dependent on the luminaire in which it is installed. Lighting reliability test system for LED/OLED Products are widely used for normal /accelerated aging, lumen maintenance measuring, lifetime evaluation and temperature characteristic testing for LED/OLED products including LED package, array, module, OLED module and luminaires.
-
Product
IK Level Tester
IK07-10
-
IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
Product
Leakage Current Tester
TOS3200
-
The Leakage Current Tester TOS3200 is designed to perform leakage current (touch current and protective conductor current) tests on general electrical equipment but not medical electrical equipment.It enables you to conduct tests that conform to the requirements of the applicable IEC, UL, JIS, and other standards, as well as the Electrical Appliance and Material Safety Law. The memory in the main unit stores the 51 types of test conditions laid down in the IEC/JIS standards for information technology equipment, household electrical appliances, audio, video electronic apparatus, luminaires, motor-operated electric tools, and electrical equipment for measurement and control and in the Electrical Appliance and Material Safety Law, thereby enabling you to conduct standard tests with simple panel operation.
-
Product
Goniophotometer for Traffic Signal Lamps
LSG-1950S
-
LSG-1950S is a high automatic test system for luminous intensity distribution of luminaires and can be applied to quality evaluation and quality control for signal luminaires, luminaires for cars, motors, vessels and Retro-reflectors. LSG-1950S system is a goniophotometer which can measure all kinds of lamps and luminaires.• Rotations of test samples around both vertical axis (-90°~+90°) and horizontal axis (-35°~+35°) • Accuracy of angle: 0.1° • Resolution of angle: 0.01° • Photometer detector: CIE class A (standard class) accuracy • All software control, high intellectual faculties and simple operation
-
Product
Integrating Sphere
-
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
Product
LT-300A Aging-Life Test System For LED Luminaires
-
Hangzhou Everfine Photo-E-Info Co., LTD
LT-300A system is widely used for normal /accelerated aging, lumen maintenance measuring, chromaticity shift measuring, lifetime evaluation and temperature characteristic testing for LED luminaires, arrays, and modules. The extrapolation of lifetime by programmable models is also available to estimate the lifetime of LED luminaires.
-
Product
Conversion Kit for Kelvin Holders
KC-4
-
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. To derive the best results from Integrating Sphere Photometry, precision lamp holders are necessary