Surface Contamination
-
Product
Surface Contamination Kit
138/2
-
The Elcometer 138/2 Surface Contamination Kit provides the user with a means for testing invisible surface contaminants including:pHchloride ionsironsalts
-
Product
Surface Contamination Monitor
IMI Inspector Alert™ V2
-
The IMI Inspector Alert™ V2 measures alpha, beta, gamma and x-radiation using a 2-inch “pancake” GM detector with high sensitivity to common beta and alpha sources. The easy-to-read digital display shows readings in your choice of µSv/hr, mR/hr, CPM, or CPS. The Total/Timer feature allows timed readings from one minute to 40 hours for precise measurement of low level contamination. An audible alert sounds when the radiation reaches a user-adjustable level.
-
Product
Geiger Counter
ONYX®
-
ONYX features a modern, streamlined look and the use of advanced technologies, making it a one-of-a-kind Geiger Counter. It weighs only 7 oz. (200g.) and measures a mere 5.1 X 2.6 X 0.9 in. (72 X 37 X 13 mm.) making it easy to transport. Despite its compact size ONYX is capable of detecting alpha, beta and gamma radiation with the same sensitivity as the IMI Inspector Alert™, and like the IMI Inspector Alert™ V2, ONYX is optimized for surface contamination measurements through use of its 2 in. pancake Geiger Mueller tube.
-
Product
Surface Quality Monitors
-
PET manufactures and markets non-destructive, non-contact surface contamination and thin film detection models and automated systems (surface quality monitoring system) capable of detecting thin layer contamination, thin films and coating down to the Angstrom level. These systems represent a major breakthrough by providing, for the first time, a quantitative measure of surface cleanliness. As surface cleanliness verification instruments, in a part cleaning environment, these products are capable of validating the cleaning quality of all the part cleaning equipment available in the market. Any of SQM model series is capable of verifying metal contamination; monitoring absence/presence of organic and/or inorganic on virtually on surfaces of all metals. They are, price/performance, the most sufficient product available for testing surface of metals for surface cleanliness. These systems operate in an ambient environment, require no sample preparation or deposit of any agents on the surface. In any parts cleaning environment where the quality and efficiency of part cleaning equipment for removal of surface contamination is highly desired, these systems provide a scientific solution by quantitatively measuring the surface cleanliness. The SQM series has the sensitivity and operational simplicity required to provide fast and cost effective surface evaluation for all metals.
-
Product
Total Reflection X-ray Fluorescence (TXRF) Services
-
A highly surface-sensitive technique, TXRF is optimized for analyzing surface metal contamination on semiconductor wafers.
-
Product
Analytical Techniques
-
Anderson Materials Evaluation, Inc.
Our numerous analytical techniques, we tackle a wide range of materials challenges and commonly combines several analytical techniques to fully address complex and multi-dimensional materials issues. Our materials analysis laboratory provides XPS surface analysis, thermal analysis (TGA, DSC, TMA), FTIR infrared spectroscopy, UV-Vis spectrophotometry and reflectivity measurements, gas chromatography – mass spectroscopy (GC-MS), SEM/EDX, optical microscopy, mechanical testing, electrochemistry and corrosion analyses, residual gas mass spectroscopy, contact angle measurements, surface contamination measurements, adhesive bonding failure analysis, facility testing for silicone contamination, mechanical testing, metallography and fractography, density and porosity measurements, volatile organic component testing, friction, and other analytical capabilities. We continue to upgrade and expand our arsenal of analytical techniques and custom analytical methods to support our customers’ needs.
-
Product
Spatial Heterodyne Surface Chemical Agent Detector
SHSCAD
-
Wide area, high areal coverage rate surface contaminant detection via LWIR reflectance spectroscopy employing eye safe broadband quantum cascade lasers (QCLs) and a high-speed spatial heterodyne spectrometer (SHS) in a handheld sensor package (~ 10,000 cm3, 10 lb).
-
Product
Optical 12,000 Meter Connector
-
Teledyne Impulse-PDM’s 5135/5175 optical connectors utilize proven standard ferrule technology and are available for multi-mode or single-mode operation.The connectors are manufactured in Titanium Ti 6Al-4V, which is electro-polished to remove surface contamination, thus improving resistance to corrosion. The engaging nuts are also manufactured in the same grade of Titanium and the threads are coated with a Nickel/PTFE composite coating to prevent galling. The connectors have been qualifi ed to 12,000 meter operating depth.
-
Product
Omicron Fiber Optic Connector
-
Teledyne Impulse-PDM’s Omicron 5030/5070 optical connectors utilize proven small form factor ferrule technology and are available for multi-mode or single-mode operation.The connectors are offered, as standard, in stainless steel to BSEN10088-3 Grade 1.4404 (316L), which is electro-polished to remove surface contamination, thus improving resistance to corrosion. Connector bodies can also be manufactured in other materials, either to address specific anti-corrosion requirements, or to increase depth rating. Engaging nuts are normally manufactured in naval brass to UNS C46400.
-
Product
Elcometer Bresle Patches
135B
-
Elcometer 135B Original Bresle Patches are used to determine surface chloride contamination and are self-adhesive rubber film patches with a sealed compartment for sampling soluble impurities from steel surfaces with a suitable solvent.
-
Product
Contamination Detection and Analysis
-
Contamination testing, detection, analysis, troubleshooting and resolution expertise to minimise downtime, maintain customer confidence, for quality & safety
-
Product
SURFACE MOUNTING
-
Direct ceiling or wall installation for spaces without recessed options or when easy installation is required.
-
Product
Surface Probes
-
Eddyfi offers a variety of mechanical designs to suit your ECA surface inspection requirements, ensuring high-quality results.
-
Product
EDX-FTIR Contaminant Finder/Material Inspector
EDXIR-Analysis Contaminant Finder/Material Inspector
-
EDXIR-Analysis software is specially designed to perform qualitative analysis using data acquired by an energy dispersive X-ray (EDX) fluorescence spectrometer and a Fourier transform infrared spectrophotometer (FTIR). This software is used to perform an integrated analysis of data from FTIR, which is excellent at the identification and qualification of organic compounds, and from EDX, which is excellent at the elementary analysis of metals, inorganic compounds and other content. It then pursues identification results and the degree of matching. it can also be used to perform EDX or FTIR data analysis on its own. The library used for data analysis (containing 485 data as standard) is original to Shimadzu, and was created through cooperation with water supply agencies and food manufacturers. Additional data can be registered to the library, as can image files and document files in PDF format. It is also effective for the linked storage of various types of data as electronic files.
-
Product
Surface Photovoltage
-
The surface photovoltage spectroscopy modules are the perfect all-in-one solution for in-depth studies of light sensitive materials such as organic semiconductors, solar cells or light sensitive dyes.
-
Product
Surface Roughness Tester
-
A precision instrument used to evaluate the texture of a surface, determining whether it is rough or smooth.
-
Product
Skin Surface Probe
SST-1
-
The SST-1 skin surface temperature probe for humans, to be taped on is re-useable and has a fast response time.
-
Product
Skin Surface Probe
SST-2
-
The SST-2 skin surface temperature probe for humans, with convenient plastic handle. Probe re-useable and has a fast response time.
-
Product
Rotary Surface Grinders
IG Series
-
Our rotary surface grinders have evolved by meeting the needs of customers in fields as diverse as electronics, aerospace, photonics, and metalworking. The surface finish on a DCM grinder is similar to Blanchard® grinders by Bourn & Koch, but that is where the similarities end.
-
Product
Surface Analysis
InSight-450 3DAFM
-
Based on the production-proven InSight® 3DAFM platform for 300mm, the InSight-450 3DAFM is ideally suited for a broad range of roughness, depth and CD applications.
-
Product
Hand-Held Surface Probe
HP 1000-SP
-
Advanced Thermal Solutions, Inc.
The HP 1000-SP is a stainless steel, single-sensor hand-held probe designed for measuring the surface temperature of solids. Its pointed tip allows for exact positioning of the sensor on the desired spot. This enhances measurement accuracy by eliminating any conduction heat transfer that may occur through the stem.
-
Product
Surface Profilers
-
Taylor Hobson offers a world leading range surface form, surface finish and metrology solutions for 3D contour,ideal for the most demanding applications.
-
Product
Surface Analysis
Innova-IRIS
-
This provides researchers a perfect combination of chemical or crystallographic information at high spatial and spectral resolution with the most advanced atomic force microscopy characterization. The Innova-IRIS can be integrated with your choice of a leading Raman system to provide the best opaque sample TERS investigations available today. However you tailor your system, your application will benefit from Bruker exclusive, high-contrast IRIS TERS probes and the best tip preservation and lowest drift, guaranteeing that alignment is preserved even over the optical integration times necessary to interrogate weak Raman scatterers.
-
Product
Ionic Contamination Test Systems
CM+ Series
-
The Contaminometer (CM+ Series) system was originally developed by Protonique, the business of industry guru Brian Ellis. They also featured in the early development programmes of "cleanliness measurement" carried out by the US Department of Defense at China Lake in the 1970s. Historically, International Standard IPC-J-STD001 stated that assemblies be cleaned to a value of <1.5µg/cm2 of NaCl equivalence. However, the new design is linked to the introduction of the new process control metric introduced by Gen3 Systems: Process Ionic Contamination Testing. The CM+ Series measure the amount of ionic contamination in accordance with all existing test methods, often referred to as ROSE testing, as well as the new PICT test.
-
Product
Surface Roughness Testers
-
Widely used in production site to measure surface roughness of various machinery-processed parts, calculate corresponding parameters according to selected measuring conditions and clearly display all measurement parameters.
-
Product
K Thermocouple Surface Probe
TP655
-
Surface thermocouple Type “K” probe. Tolerance according to IEC 60584-2 standard.
-
Product
Surface Roughness
-
Surface Roughness: these consist of a stylus attached to an arm which moves over the surface to record and measure the roughness over a specified distance, recording peak-to-valley average.
-
Product
Surface Temperature Sensors
-
Campbell Scientific offers two types of surface temperature sensors: infrared temperature (non-contact) and surface contact. Infrared temperature sensors measure the surface temperature of an object or surface by sensing the infrared radiation given off by the subject. Surface contact sensors attach directly to a surface and measure the temperature via physical contact.