Fault Injection Module
WF 3154 C-Series
The WF 3154 from WireFlow is a 4-channel Fault Injection Module for Compact RIO. Each channel provide three solid state relays that can be used to create electrical fault conditions like: Open circuit, Short circuit to battery, Short circuit to ground.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Protection Relays
Electrical protection relays for high voltage & high current protection offer protection in traction equipment as well as railway infastructure. Protection relays are used for applications like catenary voltage, short circuit, overload and ground fault detection in traction power electronics or railway substations.
-
product
High Impedance Differential Module
HID
Use the HID module in conjunction with a high-speed overcurrent relay to provide three phase high impedance differential protection for substation busbars of any voltage level. Additionally, it can also be used to protect electrical machines like transformers, generators or motors against restricted ground faults.
-
product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel
40-200-008
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
PXI 10A Fault Insertion Switch 6-chan 2-bus
40-192-012
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
product
Relays, Switches, Sensors
CR Magnetics Sensing Relays and Switches provide a simple method of monitoring electrical properties and alerting a system to a fault or event condition. These products are available with a wide variety of configurations, including time delays, various output styles and logic. From simple proving switches, to fully featured high performance ground fault sensing.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
product
Field Ground Module
SEL-2664
Schweitzer Engineering Laboratories, Inc.
Add the SEL-2664 Field Ground Module to the SEL-300G or SEL-700G to protect all the critical components in your generator with one comprehensive relay. Or, add the SEL-2664 to the SEL-2664S to complete ground fault protection on both the rotor and stator.
-
product
PXIe Power Relay Module, 12xSPDT, 16 A
42-161A-101
The 40/42-161A-101 is a PXI/PXIe 12xSPDT power relay module and is part of a range of high density power switching solutions with a choice of SPST, and SPDT relay configurations with or without hardware interlock.
-
product
PXI 16 x SPDT Power Relay Module, 5A
40-156-001
40-150/151 modules have 8xDPST or 12xDPST power relays, suitable for switching inductive/capacitive loads up to 5A at 250VAC. 40-155/156 modules have 8xSPDT or 16xSPDT power relays and 40-157 is configured as 8xDPDT.
-
product
PXI Single Microwave SPDT Relay 18GHz 50 SMA - External Termination
40-781-121
This single microwave SPDT relay module is part of the 40-781 range that consists of one or two changeover switches capable of switching frequencies to 18GHz in 50 Ohm. Versions are available with either internal or external terminations and connections are made via front panel mounted high quality SMA RF coaxial connectors.
-
product
PXI/PXIe Power Relay Module, 37-Pin D-type Connector, With Interlock
40-158-104-HI
The 40/42-158-104-HI is a PXI/PXIe high density power relay module with 8xSPDT switches rated at 5A and includes the hardware interlock option. User connection is via a 37-pin D-type male connector, hardware interlock is via a 4-pin 00 series socket (mating plug is supplied). The 40/42-158 range is available in 8, 16, 24 or 32 SPST configurations with or without hardware interlock.
-
product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXI/PXIe Microwave Relay, Dual SPDT, 67 GHz, 50 Ω, SMA-1.85, Remote Mount, Failsafe
42-780B-572-E
The 40-780B-572-E (PXI) and 42-780B-572-E (PXIe) are dual failsafe SPDT 67 GHz unterminated microwave relay modules with remotely mounted relays. The 40/42-780B range is available with one, two, three or four SPDT panel mounted relays capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions can support up to three SPDT relays in a single slot.
-
product
General Purpose Switching PXI Card
GX6325
The GX6325 is 6U switching card with 75 SPDT Form C relays with a switching power rating of 60 W. Featuring the highest density available in PXI for this type of switch card, the GX6325 is suitable for all test applications requiring general purpose, low level switching.
-
product
PXI/PXIe Microwave Relay, Dual SPDT, 12.4 GHz, 50 Ω, N-Type, Failsafe
42-780B-512
The 40-780B-512 (PXI) and 42-780B-512 (PXIe) are dual failsafe SPDT 12.4 GHz unterminated microwave relay modules. The 40/42-780B range is available with one, two, three or four SPDT switches capable of switching frequencies up to 67 GHz in 50 Ω or 2.5 GHz in 75 Ω. Connections are made via front panel mounted high quality RF coaxial connectors, SMA or N-Type for 50 Ω and 1.6/5.6 in 75 Ω versions. Remote versions are also available which can support up to three SPDT relays in a single slot.
-
product
PXI Quad 4 to 1 RF MUX SMB 75 Ohm
40-832-004
The 40-832-004 is a 75 Ohm 4 to 1 RF MUX with 4 banks in a single PXI slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
product
PXI Single Bus 32-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-501
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI Power Relay Module, 12xSPDT, 16 A
40-161A-101
The 40/42-161A-101 is a PXI/PXIe 12xSPDT power relay module and is part of a range of high density power switching solutions with a choice of SPST, and SPDT relay configurations with or without hardware interlock. Electro-mechanical power relays are used wich are suitable for switching loads up to 16 A at 250 VAC.
-
product
PXI/PXIe High Density Electro-mechanical Relay Module, 75xSPST, Normally Closed
42-145A-101-NC
The 40-145A-101-NC (PXI) and 42-145A-101-NC (PXIe) 75xSPST relay module is part of a range of high density switching modules available in Normally Open (SPST & DPST), Changeover (SPDT) and Normally Closed (SPST) configurations. Connections are made via a front panel 200-pin female connector.
-
product
PXI 24xSPST High Voltage Power Relay Module
40-330-001
The Pickering Interfaces 40-330 High Voltage Power Relay Module is suitable for applications requiring high voltage power relay switching with high density.It features current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching. It is configured as a bank of 12, 18 or 24 separate Single Pole Single Throw (SPST) relays. Connections are made via a front panel mounted 50-pin (24xSPST) or 37-pin (18 and 12xSPST) high voltage D-Type connector.
-
product
PXI 16-Channel 4-Bus 2A Fault Insertion Switch
40-197A-002
This 16-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers.
-
product
PXI 18xSPST High Voltage Power Relay Module
40-330-002
The Pickering Interfaces 40-330 High Voltage Power Relay Module is suitable for applications requiring high voltage power relay switching with high density.It features current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching. It is configured as a bank of 12, 18 or 24 separate Single Pole Single Throw (SPST) relays. Connections are made via a front panel mounted 50-pin (24xSPST) or 37-pin (18 and 12xSPST) high voltage D-Type connector.
-
product
PXI Fault Insertion Switch, 6-channel, Two Fault Buses, 10 A, Hardware Interlock
40-192A-012-HI
The 40-192A-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test:
-
product
PXI/PXIe Microwave Relay, Dual SPDT, 18 GHz, 50 Ω, SMA, Internal Termination, Failsafe
42-781A-022
The 40-781A-022 (PXI) and 42-781A-022 (PXIe) are dual failsafe SPDT 18 GHz microwave relay modules with internal terminations. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
product
PXI 2A Relay Module 80xSPST
40-139-101
The 40-139 2A Relay Series is suitable for applications requiring medium power switching with high density. Featuring 2A current capacity and voltages to 300VDC/250VAC it is useful for cost critical applications.
-
product
PXI/PXIe Microwave Relay, Single SPDT, 50 GHz, 50 Ω, SMA-2.4, External Termination, Failsafe
42-781A-721
The 40-781A-721 (PXI) and 42-781A-721 (PXIe) are single failsafe SPDT 50 GHz microwave relay modules with external terminations. The 40/42-781A range is available with one or two SPDT switches capable of switching frequencies up to 50 GHz in 50 Ω. They are available with either internal or external terminations and connections are via front panel mounted high quality SMA, SMA 2.9 or SMA 2.4 connectors.
-
product
PXI/PXIe Power Relay Module, 3xSPDT, 20 Amp
40-166-102
The 40/42-166-102 is a PXI/PXIe high density power relay module with 3xSPDT switches rated at 20A. The 40/42-166 range is available with SPST, SPDT or SP4T switching configurations. It uses power relays which are suitable for switching loads up to 20A at 240VAC (SPDT & SP4T versions) or 30A at 277VAC (SPST versions).
-
product
PXI 5A Fault Insertion Switch 20-Chan 2-Bus
40-198-002
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.