2-wire
resistance measurement method.
-
Product
PXIe-2737, 256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module
782835-37
Matrix Switch Module
256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module—The PXIe‑2737 is a high‐density 4x64 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
Product
PXI High Density Multiplexer: 99-ch, 2-Wire, 100Vrms/1A, Armature Relays
M9103A
Multiplexer Module
The M9103A, a high-density, high-power 99-channel multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time, or multiple channels can simultaneously connect if needed. This module is ideal for routing multiple analog signals to a measurement device in an automated test environment (ATE) or data acquisition systems. Each channel switch has a high and low for 2-wire switching. The high-quality armature relays are capable of switching up to 100Vrms, with up to 60W of power. Choose from the durable connector block or standard cable connections.
-
Product
VXI 16-Channel, 2-Wire LVDT/RVDT Simulation
65DL1
Simulator
NAI’s 65DL1 is a 16-channel, 2-wire, LVDT/RVDT Simulation Instrument on a VXI board. This single-slot, message-based board provides 16 independent, transformer-isolated, LVDT/RVDT, programmable 2-wire outputs (up to 34 V), wrap-around self-test, and an onboard programmable excitation supply.
-
Product
PXI Matrix Switch: 4x32, 2-Wire, 100Vrms/2A, Armature Relays
M9120A
Matrix Switch Module
The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
Product
PXI High-Density Matrix Switch: 4x64, 2-Wire, 100Vrms/0.5A, Reed Relays
M9121A
Matrix Switch Module
The M9121A is a 4x64 full crosspoint switch matrix offering high-density, high-speed signal switching in a single PXI module. The 2-wire matrix allows multiple channels to be connected in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the high-speed, long-life reed relays to support signal switching up 100Vrms with 10W maximum power. The 4-wide bus is ideal to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
Product
PXI-2576, 64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module
778572-76
Multiplexer Module
64‐Channel, 2-Wire, Multibank PXI Multiplexer Switch Module —The PXI‑2576 is a multibank PXI multiplexer switch module with 16 banks of 4x1 2‑wire multiplexers. With the flexible architecture of the PXI‐2576, you can configure it in a variety of topologies that make it suitable for parallel measurement operations requiring low‐channel counts, or you can combine all multiplexer banks to form a single high‐channel‐count multiplexer featuring 64 2‑wire channels. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
PXIe-2738 , 256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module
782835-38
Matrix Switch Module
256-Crosspoint, 8x32, 2-Wire PXI Matrix Switch Module—The PXIe‑2738 is a high‐density 8x32 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
Product
PXI-2529, 128-Crosspoint, 2-Wire PXI Matrix Switch Module
778739-01
Matrix Switch Module
The PXI‑2529 is a high‐density PXI matrix switch module that you can configure as either a 4x32 or 8x16 2‑wire matrix by using different terminal block accessories. It uses electromechanical relays that offer excellent performance for high-power signals and low thermal offset for accurate measurements at low-voltage levels. The PXI‑2529 also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
Product
- RS-485 DIN Rail Mounted Surge Suppressor
Model 8021NX
-
FEATURES: Fast Response; Automatic Recovery; Up To 20 MBPS Data Rate; DIN Rail Mounted; Triple Stage Protection; Two Wire. The Model 8021NX is a DIN Rail mounted surge suppressor for 2-wire RS-485 circuits used to protect factory data networks, or, any RS-485 network that wants to avail itself of the DIN Rail packaging concept. The Model 8021NX provides common-mode (line to ground) surge protection and differential mode (line to line) protection for balanced networks. All the inputs, outputs and ground connections are via screw terminals located on the top surface of the device.
-
Product
ANSI X3.28 to Modbus RTU Converter
Model 2399
-
* Converts ANSI X3.28 commandslinto Modbus RTU packets.* New 32 Address Mode supports multi-channel Modbus Controllers like the Watlow MLS300.* Control Modbus RTU devices from any ASCII serial source.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes serial baud rate conversion.* Internal logic is IEEE-488.2 compatible and uses SCPI commands for configurtion setup.* 2399 mounts on a DIN rail or on any flat panel.* Inexpensive way to maintain manufacturing equipment such as semiconductor fusion chambers, etc as the ANSI Controllers become obsolete.* Application Note AB23-3 describes how to use the 2399 to replace obsolete Watlow Controllers in the Axcelis/Fusion Gemini Asher.* 2399 Serial Keyboard Program lets you control and setup the 2399 and test the ANSI modes.* 239x Table Loader Program uploads ANSI Command Table entries from an Excel csv file.
-
Product
Digital And Analog Call Simulation
-
GL’s T1 E1/Analog Test Suite supports analysis and emulation of legacy protocols (MFCR2, E&M, SS1/SS4, SS5, Voice Call Signaling, 2-wire Call, SF Signaling (DTMF)) applicable to Federal Aviation Administration "FAA" within their National Airspace System "NAS" Ground-to-Ground Air Traffic Control Network and Voice System (NVS) to Analog Interphone.
-
Product
Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines
SP-RS485-12V-O
-
Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.
-
Product
Temperature Sensors
TT420
-
Features • 2-wire, loop-powered 4-20mA analog output • Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner • Compatible with PLCs, meters, and data acquisition systems • No user calibration • TT420Z 1/4" stainless steel probe • TT420S 1/4-28 threaded stud – screws into any 1/4-28 tap • TT420F mounts onto any flat surface • UL listed, Intrinsically Safe (IS) • Class I, (C, D) and Class II, (E, F, G)
-
Product
PXI Serial Interface Module
Serial Interface
The PXI Serial Interface Module offers a number of options for connecting to serial hardware. You can choose from common serial protocols, such as RS232, RS422, and RS485. The PXI Serial Interface Module also offers various isolation, hyperthreading, and multiprocessor compatibility options as well as 4- and 2-wire transceiver modes for full- and half-duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
Product
4 Wire Earth Resistance & Resistivity Tester
4235 ER
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Earth resistivity (ρ) test.● Earth testing at 20Ω, 200Ω, 2kΩ.● Earth voltage measuring : 0-300V AC.● Automatic C spike check.● Automatic P spike check.● 2-Wire test, 3-Wire test, 4-Wire test.● LCM display.● Auto ranging.● Auto power OFF.● Data hold.● 200 measurement results can be saved in the memory and recalled on the display.● Interval between auxiliary earth spikes is 1.0~50.0m.
-
Product
NI TB-2643B Terminal Block for NI 2532B as 1-Wire Dual 4x64 Matrix or 2-Wire 4×64 Matrix topology With Column Protection Resistors
782385-08
Terminal Block
The TB-2643B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x64 or 1-wire dual 4x64 matrix. You can directly connect the TB-2643B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2643B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Toxic Gas Sensor
Model 100
-
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
Product
Modbus or Laurel ASCII ProtocolSerial Output DIN Rail Transmitters
-
Laureate TM Series serial output transmitters can be jumpered for two signal levels: RS232 or RS485. Two serial protocols are selectable in software: Modbus or Laurel's Custom ASCII.Modbus protocol operation is fully compliant with the Modbus Over Serial Line Specification V1.0 (2002) for 2-wire, half-duplex connection.
-
Product
External Temperature for PT100 Probe
TGP-4104
-
This data logger uses an external PT100 probe to record high temperatures. Probes are available to measure up to 300 and 600C. These are listed in the 'You will also need' section. The PT100 probes are of 3-wire construction and use class A elements, making them more accurate than their 2-wire predecessors.
-
Product
In-Line IR Sensor
ILA
-
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
Product
Industrial Grade PCI DIO 96 Board
MS 1817
-
*96 digital input/output lines*Support s all PPI Modes (Mode0, Mode 1 and Mode 2)*5 V TTL/CMOS*Compatible with NI DIO Card*2-wire handshaking capability*Known power-up
-
Product
Dining Isolation Amplifier
-
Knick Elektronische Messgeräte GmbH & Co. KG.
To feed and Isolation of 2-wire transmitters / sensors or SMART transmitters with HART transmission. Working voltage up to 2500 V AC / DC. Available for hazardous and non-hazardous area.
-
Product
Analog Output Module For Remote I/O
Analog Output Module
The Analog Output Module for Remote I/O features a 2-wire spring terminal connection, selectable output ranges (0 V to 10 V, ±10 V, 0 V to 5 V, ±5 V, 0 mA to 20 mA, 4 mA to 20 mA, and ±20 mA) output ranges, and short circuit proof outputs. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the Analog Output Module for Remote I/O from a real‐time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low‐cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high‐speed or specialty measurements.
-
Product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781420-14
Matrix Switch Module
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
Product
Interface RS-485 and RS-422
-
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
Product
Micro-Ohmmeter
3207
-
The Ballantine 4 Digit Micro-ohm Meter 3207 measures Low Resistance in Milli and micro-ohms with precise accuracy. It employs the proven 4-wire measurement technique and eliminates the lead resistance inherent in 2-wire technique to give accurate readings.
-
Product
RS-485 and RS-422 Transceivers
-
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
Product
Party Line Intercom Conversion
COMMS Series
-
The stand-alone COMMS 300 and the OG-COMMS openGear® units provide a means to interface between two channels of 2-wire party-line intercom audio and two channels of 4-Wire analog line-level signals. The unit is capable of performing auto nulling for each channel with the push of a button. In addition, each of the 4-Wire input and output channel levels are monitored and displayed on easy to understand front panel VU meters.
-
Product
Switch Mainframe
SW1001
-
Switch between voltmeter and battery tester while testing. 66 channels max. (2-wire) to 18 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.