IR Calibrators
controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
Product
Calibration Services
-
Trescal US is accredited to ISO/IEC 17025, ANSI/NCSL Z450-1 and ANSI/NCSL Z540.3 through A2LA. Trescal has one of the largest scopes of accreditation in the country for electronic, physical and dimensional domains as well as being a factory-authorized service center for many International manufacturers.
-
Product
CALIBRATOR Multi Function Calibrator
MC140
-
The Multifunction Calibrator MC140 functions as a Voltage Calibrator, Current Calibrator, Power Calibrator, Resistance Calibrator, Capacitance Calibrator and a Thermocouple Calibrator.? Having very low uncertainties, it is ideal as a standard of these electric quantities in calibration laboratories.
-
Product
Calibration Kit
WR-10
-
This precision calibration kit contains a flush short, offset piece and broadband load which allows for a full 12-term port calibration.
-
Product
Advanced IR Gas Analyzer For Process Monitoring
T-Series
-
T-Series Inline Gas Analyzer improves gas measurement accuracy over the traditional non-dispersive infrared (NDIR) analyzers using Tunable Filter Spectroscopy (TFS™), a spectroscopic scanning technique capable of generating slices of spectra in the infrared region. Each scan produces an absorption spectrum which is used to identify compounds and provide concentration values. TFS technology improves gas identification accuracy and selectivity by subtracting out spectra from interferent gases within the same infrared regions. This spectral processing capability also provides multi-component measurement.
-
Product
Calibration and Repair Services
-
Additel calibrations provide you with high confidence and low uncertainty for your standards. Our accredited calibration laboratory utilizes primary-level piston gauge systems and high-performance controllers to provide services for the entire Additel product line. In addition, our repair technicians which are ready to help, should you have trouble with the Additel units you own.
-
Product
Decade Box, Calibrated W/Data, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL D
-
The 72-7265 CAL D from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Automated CMM Calibrated for High-Production Shop Floor Inspection
CMM Master
-
The CMM Master provides process control by delivering optimal price and performance to your application. The system brings highly repeatable, thermally insensitive, versatile, and programmable inspection to the shop floor.
-
Product
Process Calibrators
-
AMETEK Sensors, Test & Calibration
Our process calibrators include innovative handheld multifunction calibrators, multi-channel scanners, and handheld loop calibrators and power sources. Our multifunction calibrators feature a new large full color display with an advanced simplicity, easy-to-use interface. The multi-scanner is perfect when there is a need to create traceable documents for sensor calibrations. Calibrate 16 types of RTDs, and 13 types of thermocouples with our handheld calibrators.
-
Product
ATEX-Compliant IR Temperature Sensors
FLIR A310 ex
-
Explosive atmospheres need to be protected from ignition sources. Selecting equipment and protective systems which meet the requirements of the ATEX Product Regulations or similar regulations is essential. FLIR A310 ex is an ATEX compliant solution, with a thermal imaging camera mounted in an enclosure, making it possible to monitor critical and other valuable assets also in explosive atmospheres. Typical applications for the A310 ex include process monitoring, quality control, and fire detection in explosive locations. Because the FLIR A310 ex is rated IP 67, it can be installed in dusty environments. The Flame-Proof Enclosure "d"prevents any explosion transmission from the inside of the enclosure to the outside.
-
Product
Calibrated Solar Reference Cell
-
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
Product
Calibration & Demag.
Model 8515-D
-
The Model 8515-D is a medium-energy, high voltage, and capacitor discharge type ringing demagnetizer capable of desaturating Ceramic and Rare Earth magnetic materials. The Model 8515-D is easily adapted to a wide range of production and laboratory demagnetizing requirements. A modern solid-state electronic control circuit, coupled with a rugged, heavy-duty discharge SCR and fixture, make this demagnetizer a highly reliable, low maintenance unit. The electronic voltage control circuit prevents the Model 8515-D from being discharged before the preset energy level has been reached, avoiding incomplete magnet desaturation. An easy to read front panel meter monitors the capacitor voltage. The energy storage level can be easily changed in the field. Integral electrical interlock and fail-safe circuitry provide a high degree of operator safety.
-
Product
Gas Analyzer Calibration
KANE
-
Partnering with KANE we can now offer you a fast and reliable gas analyser calibration, repair and sales solution. Working closely with KANE we have we can offer you a quick turnaround time usually 6-8 working days or less.
-
Product
Calibrated Leak Standards
-
LeakMaster is a leader in the industry when it comes to the manufacturing of calibrated leak standards (calibrated leak orifices). Each leak standard is meticulously manufactured to a specific leak or flow rate at a predetermined pressure. The purpose of each leak standard is to teach, or calibrate a leak test program, and allow the leak test instrument to memorize the characteristics of a leaking part. These leaks are also introduced into production parts to simulate a “leaking or failed” part condition. LeakMaster supplies a calibrated leak standard with every leak test instrument, and provides recertification services for all of their leak standards
-
Product
Thermocouple Temperature Transmitter PC Programmable With Push Button Calibration
SEM1605/TC
-
The SEM1605TC is the next generation cost effective DIN rail mounted temperature transmitter from Status Instruments. It has been designed to accept most common Thermocouple temperature sensor inputs
-
Product
Calibration
-
Formal quality systems, such as those described in ISO 9000, require gauges to be properly controlled, logged and in calibration. Increasingly, users are specifying that the readings taken by gauges are traceable to National Standards. There are three types of coating thickness standards available from Elcometer: calibration foils, coated standards and zero test plates.
-
Product
CableEye Tester Calibration Verification Board | Cable & Harness Tester
CB50
-
Populated with precision resistors, it allows users to determine empirically whether the tester requires calibration. The CB50 may be used on all CableEye models. The CB50 is intended for periodic verification of tester calibration. To ensure that resistance measurements remain accurate, CAMI recommends yearly calibration. However, depending on environmental conditions and usage, testers may need calibrating more or less frequently.
-
Product
CableEye 4-Wire Calibration Verification Board | Cable & Harness Testers
CB52
-
The CB52 is intended for periodic calibration verification of the Kelvin 4-wire resistance measurement module – an optional, add-on module that may be purchased with any new hipot system, or added to an existing high voltage tester as an upgrade.
-
Product
IR Sensor
-
The sensor measures a very useful 0.17 mm in thickness and is made of plastic. Essentially it is a piece of robust plastic that can be used “bare” – without protective housing, such as a metal casing commonly used by other producers. The sensor it is less than 0.2 mm. thin and it is made using plastic membrane. This configuration makes the sensor so robust it can be used “bare” – without protective housing such as a metal container. Due to the fact thatSince the sensor chip can be used applied bare, means it can be used in a totally new ways, which can re-defines todays the current view on application design and reduces the cost of the entire system, and not just the sensor-element as such.
-
Product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
-
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
Product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (f) 50 Ohm
CK519A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Decade Box, Calibrated, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL
-
The 72-7270 CAL from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Acoustic Calibrators
-
We offer a range of Class 1 and Class 2 acoustic calibrators for the field calibration of any make or model of sound level meters and noise dosimeters.
-
Product
Pocket IR Dosimeter
-
Shenzhen Chuangxin Instruments Co., Ltd.
This Pocket IR Dosimeter is a handheld radiometer with the characters of high-precision, pocket, stable property and easy to use
-
Product
Instrument Calibration Services
-
Instrument Calibration ServicesCalibration is a fundamental step in the process of measurement. It ensures that the instrument used for testing accurately indicates the required measurement parameter and that the instrument is performing to its specification.
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
Sound Level Calibrator
521
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
Calibrator for Vibration Transducers
HD2060
-
Hand-held calibrator for vibration chains with frequency 15.915 Hz and levels 1 m/s² and 0.1 g, and frequency 159.155 Hz and levels 10 m/s² and 1 g. With LCD display.
-
Product
Calibration Kit
S2611
-
*S2611 Calibration Kit, * Frequency Range: up to 26.5 GHz, * Impedance: 50 Ohm, * Connector type: 3.5 mm female.
-
Product
RF Calibration Accessories
-
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.





























