Product
6GHz SMA Calibration Kits
CAL-SMA-6B
-
The CAL-SMA-6B Basic calibration kit provides the elements for performing Open–Short–Load and Through calibrations for one and two port VNA measurements.
-
Product
Electrical Calibration
GF6018A
-
Beijing GFUVE Electronics Co.,Ltd.
The equipment is compliance with national verification regulation: JJG1242005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.
-
Product
Integrating Display Output A/D Converters
-
Renesas offers a selection of high-performance integrated display output analog-to-digital (A/D) converters.
-
Product
CALIBRATOR Multi Function Calibrator
MC140
-
The Multifunction Calibrator MC140 functions as a Voltage Calibrator, Current Calibrator, Power Calibrator, Resistance Calibrator, Capacitance Calibrator and a Thermocouple Calibrator.? Having very low uncertainties, it is ideal as a standard of these electric quantities in calibration laboratories.
-
Product
Dual Display Digital Pressure Sensor [For Gas]
DP-100
-
Panasonic Industrial Devices Sales Company of America
The DP-100 Dual Display Digital Pressure Sensor is a highly accurate and reliable Pressure Sensor that is equipped with a new visual display that features a wider viewing angle and improved clarity. The pressure and set range part of the display has also been increased as another improvement. The DP-100 Series also offers a multi-function type that enables the selection of analog output (voltage/current) or external input (auto-reference/remote zero-adjustment) to comply with a wide range of applications.
-
Product
Open-Short-Load RF calibration kits
-
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
Product
Spectral Radiant Flux / Luminous Flux Calibration Standards
-
Standard lamps calibrated in luminous flux and spectral radiant flux. Versions with 2-Pi and 4-Pi emission characteristics. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
Trace Level Portable Gas Calibrator
Model T750U
-
Teledyne Advanced Pollution Instrumentation
The Model T750U is a portable, microprocessor based calibrator for precision trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.
-
Product
Combined Map Display Unit & Interface Unit Tester (COMED)
MS 1117
-
This system is used to test COMED (Combined Map Electronic Display) IFU cards. This ATE checks the LRU Status and card status and identify faulty component in the individual UUT. On fault, this suggests the possible component failure as diagnostic report, for repairing the cards.
-
Product
Calibration Services
-
Tempsens Calibration Centre is an independent unit of Tempsens instruments (I) Pvt. Ltd. We have calibration laboratories at Vadodara (Temperature Range for Contact Type Sensors -196 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C) and Bangalore (Temperature Range for Contact Type Sensors -35 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C).
-
Product
Calibration Software
-
Simplify your calibration through advanced software from Transmille. ProCal can automate your test equipment and increase productivity while reducing errors.
-
Product
Acoustic Calibrators
-
When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.
-
Product
Dual Digital Display Spring Torsion Testing Machine
Model TNS-S-I Series
-
Jinan Testing Equipment IE Corporation
This series is mainly used for torsion test of all kinds of torsion springs.
-
Product
PLTS Advanced Calibration
N19305B
-
PLTS N19305B extends the N19301B base product to perform advanced calibration techniques such as Automatic Fixture Removal (AFR)
-
Product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
-
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
6GHz SMA Calibration Kits
CAL-SMA-6F
-
The CAL-SMA-6F Full calibration kit provides all elements for Male and Female Open-Short-Load and Through calibrations for one and two port VNA measurements.
-
Product
Handheld Economic Process Calibrator
VA702
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
This Multifunction calibrator combined voltage. current .resistance .thermocouple temperature .RTD in one device.
-
Product
Displays – LCD, TFT, OLED, Touch - 7-Segment Displays
-
Vishay’s 7-segment LED displays are used in a wide variety of end products including test and measurement equipment, point-of-sale terminals, telecom systems, office equipment, consumer electronics, and medical equipment. Options include 7 mm, 10 mm, and 13 mm leaded and surface-mount packages, and color choices including green, red, orange-red, yellow, soft orange, super red, and super yellow.
-
Product
Standard Handheld Display
TW-3.0-S
-
The TW-3.0-S Standard Handheld Display is a modern, slimline, multifunctional load monitoring device which is unique to DLM. This innovative design is built with the user in mind. It has a large, high quality LCD screen which is optically bonded removing the need for a back light and improving clarity in bright sunlight. For ease of use each handheld can be given a customisable friendly name made visible on the screen to make instant identification possible. This multi featured high precision unit ensures reliable load readings while also being simple to operate. It can be used in conjunction with any DLM manufactured load cell, just look for the d+ logo on our products.
-
Product
Calibrating Equipment
-
Stability DC : < 0.01 %FS / 3 min, AC : < 0.02 %FS / 3 minRipple : < 0.2 %Power Supply : 230 VAC, 50 (60) HzPower Consumption : < 250 VAOperating Temperature : 5ºC to 35ºCRelative Humidity : ≤ 80 %Distortion : < 0.5 %Display : 51/2 Digit LED Digital DisplayStep adjustment of Output Signal : 100 %FS / N, 10 %FS / N,%FS / N, 0.1 %FS / N (N = 4, 5, 6, 10 and 15)Dimensions : 190mm (H) x 480mm (W) x 545mm (D)Total Weight : 22.5 kgs (approx.)
-
Product
ARINC-708/453 2-Channel Test & Simulation Module for the Weather Radar Display Databus
M8K708
Test Module
The M8K708 module is an ARINC-708 / 453 2-channel test and simulation module for the Weather Radar Display Databus. The M8K708 supports two ARINC-708 / 453 channels, each selectable as transmit or receive. Each channel implements an 64K×16 FIFO and supports polling and/or interrupt driven operation.The M8K708 comes complete with Windows software, a C-driver software library including source code and may be used with Exalt, Excalibur’s Analysis and Laboratory Tools, a Windows monitoring application. In addition, Excalibur produces adapter cables that convert the carrier board I/O Molex™ connector to two twinax CJ70-49 connectors. The cable may be purchased at an additional cost.
-
Product
Display
Signals Gallery
-
Program “Signal gallery” is used for viewing and analysis of the recorded signal (whether from HD or in remote way).
-
Product
Dry Block And Bath Calibrators
-
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
Product
Calibrators
-
Orbit Controls calibrators are suitable as signal sources for test benches or laboratories. They can be used as generators for calibrating and testing electronic measuring devices or assemblies, both by manufacturers and by companies that must perform periodic calibration tasks for quality certification.
-
Product
Humidity Calibration Set
-
The humidity transmitters as all other measuring instrumentsshall be periodically checked and eventually adjusted. The most simple solution for this purpose is the E+E calibrationset.
-
Product
Light / Lux Meter, Calibrated, 50000 lx, 100 lx, 4 %, 185 mm, 78 mm, 38 mm
72-7250 CAL
-
The 72-7250 CAL from Tenma is a digital light meter with RS232 capability. It has custom one-chip microprocessor LSI circuit which ensures high accuracy. The meter features 13mm (0.5”) super large LCD display with contrast adjustment for best viewing angle, data hold and auto power off. It records maximum, minimum and average readings with RECALL facility. The 72-7250 has RS-232 PC serial interface, user selectable lighting type (tungsten, fluorescent, sodium or mercury, daylight) and zero adjustment by push button. The meter operates from 9V battery.