PT
a type of intrument transformer enabling secondary connected metering.
-
Product
WaveLink Dx20-PT Adjustable Positioner Tip Kit
Dx20-PT-KIT
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Multi-Sensor Thermal Imaging Camera for Condition Monitoring
A310 PT
-
FLIR A310 pt thermal cameras can be installed almost anywhere to monitor the condition of your critical equipment and other valuable assets. Designed to help safeguard your plant and measure temperature differences, they allow you to see problems before they become costly failures -- preventing downtime and enhancing worker safety. FLIR A310 pt is ideal for various applications that require temperature measurement capabilities including: substation, transformer, waste bunker, and coal pile monitoring.
-
Product
Instruments Transformers Tester
Calport 100 Plus
-
Calmet Smart Calibration Devices
Three phase instrument transformers and electricity meters tester class 0.1 or 0.2. It makes possible CT and PT testing on site or in the laboratory. We recommend a new replacement - TE30 Working Standard
-
Product
Solid Electrode Spectrochemical Cell
-
The spectroelectrochemical cell enables acquisition of infrared and Raman spectra of working electrode discs (variable sizes, up to 10 mm OD) under flowing solution. Working electrodes available include: Pt, Au, Ag, Cu, glassy carbon, etc. The cell uses a Pt-wire counter electrode and a Ag/AgCl reference electrode. For use with the EZpump peristaltic pump. Adapts to the Harrick Praying MantisTM Diffuse Reflection Accessory.
-
Product
Disk Peel Tester
DRK186
-
Shandong Drick Instruments Co., Ltd.
DRK186 Disk peel tester is applied to test the ink layer bonding strength of plastic film printing and PT print. To test the surface adhesion state of vacuum coating, surface coating, composite process.
-
Product
Pitot / Static Tester for Laboratories and Workshops
ADSE 741
-
The ADSE 741 is a complete high performance three channel Ps, Pt and AoA stand-alone test bench specially designed to be used in the workshop or in the laboratory to test and calibrate all air data equipment such as altimeters, vertical speed indicators, air speed indicators, pneumatic AoA (Angle of Attack) indicators, MACH-meter, air data computers, specific probes and sensors.The high precision embedded sensors enable the ADSE 741 to be used as a pressure standard.The user interface is programmed underWindows and Labview, with a data base managed in a spreadsheet for easy evaluation, management, statistics and presentation.
-
Product
Multifunction Substation Test Set
STS 4000
-
STS 4000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers, designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid.
-
Product
Aircraft Simulator
ePlane PC
-
Pneumatic connections Ps, Pt and AoA (option)High accuracy, high resolutionSelectable pressure units: hPa; mb; in Hg; mmHg; ft; m; kts; km/h, ft/min; and Mach number and needle equipment visualisationSoftware executable under Windows 2000 and XPUSB cable for PC connection
-
Product
Dual MAX31865 PT-1000 RTD to Digital Breakout
SEN-30202-PT1K
-
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information.
-
Product
Isolated RTD Input Module
ADAM-3013
-
1000 VDC 3-way optical isolationBuilt-in microprocessorSwitch configurable for 0~5 V, 0~10 V or 0~20 mA outputsSwitch configurable Pt and Ni RTD input ranges
-
Product
WaveLink Dx10-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly
Dx10-PT-KIT
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Enlarge Environmental Chamber
REXMED REC-250
-
MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
Transformer Analyzer
505
-
The UTEC 505 Transformer Analyzer is designed for testing current transformers (CT) and potential transformers (PT) without interruption of the customer’s service. This instrument measures CT admittance, CT ratio, CT primary-to-secondary phase angle and the voltage, current and phase angle of the service. With the ‘Burden CT/PT Option’, it determines the CT secondary burden capability, the regulation of the PT and its secondary burden capability and provides for CT core demagnetization.
-
Product
Primary Injection Testing
-
For primary injection testings, PONOVO has been providing users, various testing equipment, including CT/PT test set, Single phase universal test test upto 250A and 1000A, etc. CT/PT tester could be used for testing all kinds of CT testing, with additional PT testing functions.
-
Product
6 Digital Microprocess AC Watt-hour Meter
WHM
-
‧ 6 Digits Display (999999)‧ CT×PT rate free setting 1~4095 times.‧ Pulses output (option).‧ DIN Size 96×48mm.
-
Product
Environmental Chamber
REXMED REC-280
-
MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
General Purpose Lab Oven
REXMED ROV-180
-
MOD. ROV-180, AC 110/230V, Plug type: , General purpose lab oven, dry air / hot air sterilizer, HS CODE: 841780, UNCCS CODE: 447483, UMDNS CODE: 14410, Main construction: powder coated steel and SS304, Controller: Microprocessor based PID controller, water proof keypad with timer, ˚C/PV and ˚C/SV display and setting, Timer: 9999/min, 9999/hr, Timer has DELAY_ON and DELAY_OFF function and at the end of operation audio and visual warning, Working range: Ambient +5˚C~250˚C, Stability at 37˚C: ±0.2˚C, Uniformity at 150˚C: ±1.5˚C, Sensor: PT 100Ω, Temperature audio and visual warning for AL-H and AL-L and OFS correction setting, Heater: 600W X 2pcs, Chamber: L40 X W40 X H50cm, Capacity: 80L, chamber with key lock, W/S: shelf X 2pcs
-
Product
Current Transformer Analyzer/Tester
GF1061
-
Beijing GFUVE Electronics Co.,Ltd.
Portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Voltage Data Logger Single Channel
VAT601-V1
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multifunction data logger with K J PT type current .voltage : K.J . PT100. PT1000. mADC. AAC. VDC.VAC.
-
Product
Digital Panel Meter
-
Nippen Electrical Instruments Co.
To be supplied with the right meter, simply furnish the following details in your order: Model Number, Description of the Meter. Accuracy Class. Voltage Input (110 Volts from PT, 240 Volts line to neutral or 415 Volts Line to Line). PT Ratio specifies the High Voltage Primary first ( 33 kV.110V). Current input (5Amps or 1 Amp secondary ) CT ratio (e.g. 100/5 Amps. etc.). Aux. Supply : 50/60 Hz (240VAC of 110/VAC). Dimension : 96 x 96mm or 48 x 96 mm or 144 x 144 mm.
-
Product
Voltage Data Logger Single Channel
VA601-V262
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multifunction data logger with K J PT type current .voltage : K.J . PT100. PT1000. mADC. AAC. VDC.VAC.
-
Product
IGBTs
-
ST offers a comprehensive portfolio of IGBTs (Insulated Gate Bipolar Transistors) ranging from 300 to 1700 V, both in planar punch-through (PT) and trench-gate field-stop (TFS) technologies. IGBTs belong to the STPOWER family.
-
Product
Multifunction Substation Test Set
STS 5000
-
STS 5000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid.
-
Product
Turns Ratio Testing
-
The transformer turns ratio test, or TTR test, confirms that the transformer has the correct ratio of primary turns to secondary turns. Using this test correctly can help to identify tap changer performance, shorted turns, open windings, incorrect winding connections and other faults inside transformers. Megger’s range of TTR testers are robust to withstand the harsh conditions that some transformer testing in. The range includes varying features to simplify and speed up testing as well as 3 phase TTR testers and PT and CT TTR testers.
-
Product
Transformer Testing Equipment
-
Offering you a complete choice of products which include Automatic Transformer Turns Ratio Instruments (ATRI- 3), Automatic Transformer Turns Ratio Instrument (ATRI-201), VTRI-2000 ( Transformer turns ratio instrument ), Current Transformer Test Set (CTC-1), Potential Transformer Tester ( PT Tester ) and Current Transformer Tester ( CT Tester ).
-
Product
Current Data Logger with USB VA601-A2 0-600A
VA601-A110
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multifunction data logger with K J PT type current .voltage : K.J . PT100. PT1000. mADC. AAC. VDC.VAC.
-
Product
Transformer Turns Ratio Meter
-
International Biological Laboratories
Transformer Turns Ratio Meter is compact in size and is capable to measure actual turns ratio of different types of transformers like Distribution, Power, CT, PT, Auto-transformers, Control & Measuring transformers etc.
-
Product
Environmental Chamber
REXMED REC-400
-
MOD. REC-400, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,506 Watts, 11,962 BTU/hr, 3,020 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
CT/PT Bus-Bar Safety Protector
6450
-
The TESCO CT/PT Bus-Bar Safety Protector (Catalog No. 6450) has been developed to assist in the safe disconnect of a hot sequenced current transformer. After service is disconnected, the TESCO CT/PT Bus-Bar Safety Protector is slid over the bus-bar of the load side of the transformer and prevents accidental connection and/or arcing.