Filter Results By:
Products
Applications
Manufacturers
Data Acquisition
senses the physical, represented as an analog signal, that is then converted to digital data. AKA: DAQ
See Also: Data Acquisition Systems, PCI Data Acquisition, DAQ, Digitizers
-
product
PXI Express Data Acquisition Platform
PXI Express is the fastest data acquisition platform currently available with unmatched bandwidths in excess of 1 GB/s and latencies less than 1 µs. This makes PXI Express-based data acquisition systems ideal for data intensive applications like high-speed digitization, signal-generation, and communication interfaces where high sample rates and channel counts could choke other interfaces.
-
product
16-CH 12/16-Bit 100 kS/s Low-Cost Multi-Function DAQ Cards
PCI-9111 Series
ADLINK PCI-9111 series are 16-CH, 100 kS/s low cost multi-function DAQ card. The PCI-9111 series feature flexible configurations on analog inputs. A RC filter is implemented on each A/D input channel for user to attenuate or filter input signal. The PCI-9111 series provide analog inputs with 5 programmable input ranges for bipolar inputs. The PCI-9111 series also support automatic analog input scanning. PCI-9111DG provides 12-bit A/D resolution while PCI-9111HR provides 16-bit A/D resolution. The PCI-9111 series also feature 1-CH 12-bit analog output, 16-CH TTL digital inputs and 16-CH TTL digital outputs. ADLINK PCI-9111 series deliver cost-effective and reliable data acquisition capabilities, and is ideal for a broad variety of applications.
-
product
Data Acquisition (DAQ) And Real-time Control Systems
Our data acquisition devices are capable of storing hundreds of analog and digital channels at full speed while allowing in parallel data to be sent out in real-time to any 3rd party EtherCAT master controller. We have brought the worlds of data acquisition and real-time control closer together which will save you time and money in a big way.
-
product
16-CH 16-Bit 250 kS/s Low-Cost Multi-Function DAQ PCI Express Cards
DAQe-2213/2214
ADLINK DAQe-2213/2214 can sample up to 16 AI channels with different gain settings and scan sequences. It makes them ideal for dealing with analog signals with various input ranges and sampling speeds. These devices also offer differential mode for 8 AI channels in order to achieve maximum noise elimination.
-
product
PXI 32x8 Matrix Module, 2-Pole, 2A, 60W
40-580-001
The 40-580 is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 32x8 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems. The user signal connection is via a robust 160 pin DIN 41612 connector that is fully supported by the wide range of Pickering Interfaces cable and connector accessories.
-
product
Archiving
Hercules
*Infinitely expandable data storage*Fully automated operation*Seamless integration with the HGL acquisition and analysis software*Store, back-up and retrieve mission critical data transparently*Total data transportability, including offsite locations*High-performance throughput
-
product
High Temperature Diametral Extensometers (1000 C)
Model 3580
Jinan Testing Equipment IE Corporation
This model is for diametral strain measurement with furnace and induction heating systems. Quartz rods and water-cooling allow the unit to be used for high temperature testing of metals, ceramics and composites. With induction heating, this model often can be used without water-cooling. When used in furnaces, the extensometer is often mounted directly to the furnace side cut-out. Optional load frame mounting brackets are available for supporting the extensometer in cases where furnace mounting is not possible. These optional mounts are used with induction heating or furnace systems. The Model 3580 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
PXI Base Module
PA72
The PA72 platform is a platform of flexibility. It consists of a base board and one or two daughter boards. In daughter boards there is choice from several different generators, digitizers, filters, and Flexible Digital I/O modules. Also custom daughter boards can easily be created. This allows you to configure a data acquisition card exactly tailored to your needs. The PA72 concept provides a flexible and cost effective solution for medium and high end analog functions.
-
product
PXI Very High Density Multiplexer, 5-Channel, 32-Pole
40-675A-002-5/32
The 40-675A-002-5/32 is a 5-channel, 32-pole MUX and is part of our range of PXI very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. The modules use high quality electromechanical signal relays allowing each channel to switch current up to 1A at 150VDC/100VAC. Connections are made via a front panel 200-pin connector.
-
product
PXI Single 66x8 Matrix, 1-Pole
40-541-021
The highest density single slot PXI reed relay matrix module on the market today. This range also includes a 132x4 and 33x16 reed relay matrices with 1-pole switching. They are constructed using high reliability sputtered ruthenium reed relays, offering >10e9 operations to give maximum switching confidence with long life and stable contact resistance. Typical applications include signal routing in Functional ATE and data acquisition systems.
-
product
Industrial Automation
Industrial automation involves integrating Data Acquisition and control logic with various third-party components, devices, and sensors. Bringing together this broad mix of technologies, and integrating them into a final solution requires Mechanical, Electrical, and Software Engineers, and a common technology platform to ensure all system components work cohesively. Leveraging the LabVIEW, PXI, and CompactRIO, platforms we can solve extremely complex industrial automation challenges and deliver success for our customers that could not otherwise be achieved.
-
product
Aluminum Portable Telemetry System with Integrated Keyboard and Display
LS-84-AP
The Lumistar LS-84-AP Rugged Aluminum Portable Data Unit offers a low cost, high performance COTS solution for aportable quick look ground station. Lumistar LS-25 FMReceivers or LS-25-D2 Down Converters with LS-35-R Multimode IF Receiver, Bit Synchronizers and Multi-function PCM Decommutators, and LS-71D/A Converters can be installed inthis rugged high quality portable computer and bundled with theLumistar setup, control, and monitoring software to achieve anaffordable alternative to the often expensive, proprietary architecture products of other suppliers. The flexible design allows the user to define the desired data acquisition cardconfiguration to unique requirements.
-
product
Data Acquisition Modules
Omega offers a high performance Data Acquisition products. Omega carries the right product for the input/output requirements of your application.
-
product
Pressure Calibration Custom Systems
Our custom systems integrate standard Fluke Calibration products, pressure generation and control accessories and/or data acquisition hardware to meet customer requirements. Systems may be mobile calibration carts or rack mounted instrument panels or benches. 7250-sys Ruska gas pressure controller system, and engineered systems customized to fit your application needs.
-
product
PXI MUX 4 Bank, 16 Channel Screened 1 Pole
40-610-021-S-4/16/1
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
product
PXI MUX 1-Bank of 80 Channel 1-Pole
40-615-021-1/80/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
3D Measuring Laser Microscope
LEXT OLS5000
The OLS5000 laser confocal microscope precisely measures shape and surface roughness at the submicron level. Data acquisition that's four times faster than our previous model delivers a significant boost to productivity. Measure samples that are up to 210 mm tall. Capture the shape of any surface. Total magnification: 54x - 17,280x
-
product
3-Slot Data Acquisition Mainframe With GPIB And Three 20-Channel Multiplexer Modules
DAQ973MB
The DAQ973MB Better Multiplexer Bundle offer includes a DAQ973A three-slot data acquisition mainframe and three 20-channel DAQM901A multiplexer modules. This bundle provides the following:3-slot mainframe with USB, LAN, and GPIB6.5-digit (22-bit) internal DMM60 channels of multiplexer switches6 channels of dedicated current measurements2- and 4-wire scanning300 V switching80 channels/s scanningbuilt-in thermocouple reference junctionbuilt-in signal conditioning to measure thermocouples, RTDs and thermistors, AC / DC volts and current; resistance, frequency / period, diode test, and capacitance
-
product
USB-6356, 8 AI (16-Bit, 1.25 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device
781444-02
8 AI (16-Bit, 1.25 MS/s), 2 AO (3.33 MS/s), 24 DIO USB Multifunction I/O Device - The USB-6356 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, and four 32-bit counters/timers for PWM, encoder, frequency, event counting, and more. Onboard NI-STC3 timing and synchronization technology delivers advanced timing functionality, including independent analog and digital timing engines and retriggerable measurement tasks. The USB-6356 is well suited for a broad range of applications, from basic data logging to control and test automation. The included NI-DAQmx driver and configuration utility simplify configuration and measurements.
-
product
DAQ-Embedded Computers
MIC-1800 series units are standalone embedded computers with integrated data acquisition modules and signal conditioning.
-
product
SH68M-68M-EPM, 68-Pin Male VHDCI to 68-Pin Male VHDCI, Twisted Pair, Shielded Multifunction Cable
190233-01
68-Pin Male VHDCI to 68-Pin Male VHDCI, Twisted Pair, Shielded Multifunction Cable - The SH68M-68M-EPM Cable, sometimes referred to as SHC68-C68-EPM, connects DAQ devices. The cable includes separate digital and analog sections, individually shielded twisted pairs for analog inputs, individually shielded analog outputs, and twisted pairs for critical digital I/O. The SH68M-68M-EPM Cable is offered in different lengths.
-
product
Optical Time Domain Reflectometer
Alnair Laboratories Corporation
The FDM-OTDR encodes multiple probe pulses at different frequencies, in the same time frame that conventional C-OTDRs send out a single pulse. This frequency-division-multiplexing enables larger data acquisition in the same measurement time compared to C-OTDRs. As a result the FDM-OTDR can achieve higher dynamic range with the same measurement time, or a significantly reduced measurement time with the same dynamic range.
-
product
PXI High Density Mux 10 Channel 8 Pole
40-670A-021-10/8
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
product
Digitize, Quantify, Collaborate With Your Unique Automated Petrographic Microscope
ZEISS Axioscan 7 for Geology
Digitize your thin sections with Axioscan 7 – the reliable, reproducible way to create high quality, digitized petrography data in transmitted and reflected light. Uniquely designed for petrographic analysis, the Axioscan 7 Geo combines unique motorized polarization acquisition modes with unprecedented speed and a rich software ecosystem for visualization, analysis, and collaboration.
-
product
High Speed DAQ Card
With 25 MS/s, 100 MS/s or 250 MS/s the high speed input cards are suitable for the acquisition of ultra fast, accurate and high resolution transient signals in high speed mechanical tests or electrical/electronic environments. 14-/15-/16-bit resolution; dynamic resolution increase. available 5/18
-
product
PXI 2 Amp MUX, Dual 32-Channel 1-Pole
40-635-005
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
product
Intelligent 16 Bit Data Acquisition
CPCI-AD16
The CPCI-AD16 module provides a 3U high performance data acquisition subsystem. The Local DSP can be used to simply move data samples to the CPCI bus or can provide processing functions such as limit checking, FFT’s, digitalfiltering, etc. Application software can be downloaded to the DSP via the CPCI interface. Instrumentation amplifiers provide over-voltage protection, gain and filtering on a per channel basis. Internal scan and trigger clocks are derived from either the CPCI bus clock or the local DSP clock. Dual 32 bit timers can programmed to pace the acquisition process. The CPCI-AD16 can also accept external scan and trigger signals from a front panel connector.
-
product
General-Purpose Analyzer Systems
Brüel & Kjær Sound & Vibration A/S
Sonoscout is a system that uses an app on an iPad to control a wireless data acquisition unit. This rugged front-end can connect up to 12 transducers, such as a binaural headset for in-vehicle recording at the user's ear positions. The front-end is battery-powered and transmits data to the iPad for recording or records directly to SD card inside the front-end, avoiding the need to use Wi-Fi. The intuitive app makes it simple to either perform basic analysis, or to replay and listen to files in order to validate recordings before exporting them for further analysis and archiving in PULSE Reflex.
-
product
PXIe-4300, 16-Bit, 8-Channel, 250 kS/s, 300 V, Ch-Ch Isolated PXI Analog Input Module
781337-01
16-Bit, 8-Channel, 250 kS/s, 300 V, Ch-Ch Isolated PXI Analog Input Module—The PXIe‑4300 provides integrated data acquisition and signal conditioning for high-voltage measurements. It provides increased accuracy, simultaneous sampling, and synchronization features for scalable measurement systems. The PXIe‑4300 includes 300 Vrms channel‑to‑channel CAT II isolation and 3,300 Vrms channel‑to‑earth 5 second withstand isolation to protect users and equipment from hazardous voltages. This module offers programmable lowpass filtering, DC input coupling, and two PFI lines for digital input triggering. The included NI‑DAQmx driver simplifies hardware and configuration and measurement.
-
product
PXI 20 Banks of 4 Channel 2 Pole MUX
40-615-022-20/4/2
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.