Filter Results By:
Products
Applications
Manufacturers
Differential Probes
Measure signals that are not ground referenced.
-
product
Differential Probe
DP-35
*High Sensitivity, High Voltage Model .*35MHz/1600 Vp-p Max.*Input Impedance 8MΩ//2.5PF*x10, x100 Attenuator, Easy to Convert.*Separating Design(Standard No.114205) Convenient & Durable.
-
product
400 MHz High Voltage Differential Probe
DP0001A
The DP0001A is a 400 MHz high voltage differential probe with 2 kV mains isolated or 1 kV CAT III rating designed for making accurate high-voltage power measurements required for testing today’s WBG power devices, power converters or motor drives.
-
product
1kV, 25 MHz High Voltage Differential Probe Without Tip Accessories and with Auto Zero Disconnect
HVD3102A-NOACC
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
Differential Probe
DP-100
*This is the first detachable design (patent for 15 years)*High frequency, big power using. Max. Measuring is 7000Vp-p.I*t is capable for any brand of digital and analog oscilloscopes.*Additional AC Adaptor.*16MΩ high input impedance.
-
product
Current Probe
DCP-BTA
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
product
2kV, 400 MHz High Voltage Differential Probe
HVD3220
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
Differential Probe
DP-8V
*MAX. Input Voltage: ±4KV DC or 8KV p-p or AC 2.8KV rms*Bandwidth: DC-50MHz*Input Impedance 20MΩ// 2PF*x10, x100, x1000 Attenuator*To Ground MAX. Voltage: 4KV CAT III*Output Impedance 50Ω
-
product
Replacement Spade Terminals for High Voltage Differential Probe
PK-HVA-05
Replacement Spade Terminals for High Voltage Differential Probe
-
product
6 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip
D610-A-PB2
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Differential Probe
DP-800HS
*1:1 High Sensitivity*100 Gain Design*x1, x10, x100 Attenuator*Bandwidth: DC-50MHz*Input Impedance 3MΩ // 2.5PF*Max. 800Vp-p Input or ±400V DC or AC 280V RMS*Output Impedance 50Ω
-
product
Swivel Tip Adapter for ZD Differential Probe Qty 1
PACC-ZD005
Swivel tip adapter for ZD differential probeQty 1
-
product
Differential Active Probe, 1.7 GHz
DP0013A
The Keysight DP0013A is the 1.7 GHz model of the DP001xA Series differential active probes. These provide the superior general-purpose differential signal measurements required for many of today’s high-speed power-related measurements such as motor drives, automotive differential bus measurements, and high-speed digital system designs.
-
product
Differential Probe
DP-16VF
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-150MHz*Input Impedance 20MΩ // 5PF*X400, X4000 Attenuator*To Ground MAX. Voltage: 3.5KV CAT III*Output Impedance 50Ω
-
product
DL-HCM Series High-Temperature Solder-In Tip
DL-HCM-HiTemp
60 V of common mode and 80 V differential input range with 1 GHz of bandwidth, make these probes ideal for lower voltage GaN power conversion measurements. The 60 V of common mode is well suited for handling any float of the battery and bulk/absorption voltage during charging, while the 80 V differential input range provide margin for any overshoot.
-
product
6 GHz ProBus2 Differential Probe with Adjustable Tip
D600A-AT-PB2
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Thermometer, 2 Channel, 0°C to +1767°C, 175 mm, 85 mm, 30 mm
72-7715
Compact handheld thermometer is ideal for a variety of industrial, residential, HVAC and equipment testing applications. It accepts a wide variety of industry standard thermocouple probes and features internal data logging of up to 100 records. Dual inputs allow simultaneous measurement of two separate zones with independent readout or differential (T1-T2) display
-
product
Acute High Voltage Differential Probe, 50x/500x, 100MHz, 3500V
ADP5100
*USB Powered (or Power Bank)*Bandwidth up to 100 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
Differential Probes < 1.5GHz
Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point
-
product
Acute High Voltage Differential Probe, 50x/500x, 25MHz, 3500V
ADP5025
*USB Powered (or Power Bank)*Bandwidth up to 25 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
Residential/Commercial Combustion Analyzer Kit for Oil-Fired Appliances /Printer
C165+OILKIT
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C165+ Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. The new LINK feature connects the included wireless pipe clamp temperature probes and other optional probes to the C165+. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
DH Series Tip - CrossSync PHY PCIe5 CEM x16
DH-CSPHY-PCIE5-CEMX16
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.
-
product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
product
Other Passive Probes
Probes connect the input of the oscilloscope to test points on the device under test (DUT). There are many types, including: high impedance passive, low capacitance, single-ended active, differential active, high voltage, and current probes. This is the first in a series of three articles on probe selection and application, and will focus on passive probes. Part 2 and part 3 will address active probes and current probes, respectively.
-
product
Quad Input Logging Thermometer
DT304
UEi Test & Measurement Instruments
This series of Digital Thermometers offers a unique combination of features including logging capabilities with 9,999 memory positions and a USB interface and software, one, two and four inputs offering relative and differential readings. The Apollo also offers a solution to storing probes and is manufactured to conform to the IP67 standard, meeting performance expectations of water submersion and high-pressure dust resistance
-
product
4 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip
D410-A-PB2
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe
T3HVD7000-100
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe.
-
product
Acute High Voltage Differential Probe, 20x/200x, 25MHz, 1400V
ADP2025
*USB Powered (or Power Bank)*Bandwidth up to 25 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
Differential Probe
DP-25
*Econmical High Voltage Model*25MHz/1400Vp-p Max.*3 Range: x20/ x50/ x200*Input Impedance 4MΩ//1.2PF*Separating Design(Standard No.114205) Convenient & Durable.
-
product
Replacement Hook Clips for High Voltage Differential Probe
PK-HVA-03
Replacement Hook Clips for High Voltage Differential Probe
-
product
DH Series QuickLink Adapter Kit with 3 x QL-SI Tips
DH-QL-3SI
Teledyne LeCroy’s DH series 8 to 30 GHz differential probes offer the combination of bandwidth, input range and offset capability to address any high-speed probing requirement from debugging serial data interfaces to validating DDR memory systems. DH series probes provide superior loading characteristics and are calibrated with a custom “fine-tuned” frequency response. The ultra-low loading and flat frequency response ensure accurate measurements.