High Temperature Diametral Extensometers (1000 C)
Model 3580
Jinan Testing Equipment IE Corporation
This model is for diametral strain measurement with furnace and induction heating systems. Quartz rods and water-cooling allow the unit to be used for high temperature testing of metals, ceramics and composites. With induction heating, this model often can be used without water-cooling. When used in furnaces, the extensometer is often mounted directly to the furnace side cut-out. Optional load frame mounting brackets are available for supporting the extensometer in cases where furnace mounting is not possible. These optional mounts are used with induction heating or furnace systems. The Model 3580 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Miniature Transverse (Diametral) Extensometers
Model 3475
Jinan Testing Equipment IE Corporation
A miniature extensometer designed for general purpose transverse or diametral strain measurements on small or thin specimens. May be used simultaneously with the Model 3442 miniature axial extensometers or the Model 3542 axial extensometers.
-
product
High-Temperature Extensometers < 600 °C Capacitive
Instron® High-Temperature Extensometers are perfect for testing advanced composites, metals, polymers and other materials at elevated temperatures. This series incorporates a capacitive sensor that does not require any cooling. The extensometers come standard with a sensor conditioner unit providing a 0-10 V output with exceptionally low noise. These extensometers can be attached to round and flat specimens to perform tensile, compression, and cyclic tests.
-
product
Video Extensometers
AMETEK Sensors, Test & Calibration
The VE1 is a high precision video extensometer that uses a non-contacting optical measurement based on a digital camera and real time image processing to measure the longitudinal and transversal strain during tensile tests.
-
product
High Temperature Axial Extensometers
4 models cover a variety of applications for high temperature testing 1 un-cooled model for use inside chambers up to 600 °C (1000 °F) Other models for use with split furnaces and induction heating, up to 1600 °C (2900 °F)
-
product
High Temperature Transverse Extensometers (700 C)
Model 7675
Jinan Testing Equipment IE Corporation
Designed for transverse or diametral strain measurement in environmental chambers where the entire extensometer must be exposed to elevated temperatures. These capacitive extensometers may be used up to 700 C (1300 F) without any cooling.
-
product
Averaging Extensometers for ASTM D5656 Shear Tests
Model 4013
Jinan Testing Equipment IE Corporation
The Model 4013 extensometer meets the requirements of ASTM D5656 for measuring the strain properties of an adhesive in shear. It uses different contact point spacing compared to the extensometer shown in D5656. This makes it much easier to mount and eliminates the slippage problems associated with the design shown in the ASTM standard. The Model 4013 is available with all of Epsilon’s temperature configurations. It has a 3.0 mm (0.12 inches) full scale measuring range. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 4013 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Deflection Gauge Extensometers
We supply a wide range of deflection gauge extensometers ideal for measuring deformation in three and four point bend tests and in compression testing applications.
-
product
High Temperature Un-Cooled Extensometers (700 C)
Model 7642
Jinan Testing Equipment IE Corporation
These extensometers use a high-temperature capacitive sensor and do not require any cooling. They will operate up to the maximum temperature limit of most environmental chambers used in materials testing. The Model 7642 is ideal for testing composites, metals and high temperature polymers in tensile, compression or cyclic testing. All units can be displaced in both compression and tension. The extensometer is supplied with the advanced DT6229 controller. The standard output is 0-10VDC analog signal, factory calibrated with the extensometer. This system provides a number of functional enhancements, including high speed digital output, built in calibration and tare functions, analog and digital filters, and more.
-
product
Averaging Clip-on Extensometer
The Instron 2650 Series Biaxial Extensometers are ideally suited for testing a wide range of materials, including polymer matrix composites, metals, and plastics over a range of temperatures. Two sensors measure axial strain on opposite sides of the specimen. Versions are available which provide either a single averaged axial output or 2 independent axial outputs. The extensometers meet the calibration requirements of ASTM E83 class B1, ISO 9513 class 0.5, and ISO 527.
-
product
Static Axial Clip-On Extensionmeters
The 2630 series and W-6280 series of extensometers offer speed of attachment and ease of use. The light-weight, rugged cross-brace design eliminates errors caused by physical distortion, while built-in protection ensures that damage is not caused by over-extension. The low operating-force arms of the extensometer reduce the possibility of knife-edge slippage when testing hard or smooth surfaced materials. The 2630 series extensometers can be installed or set in place accurately and consistently, with the gauge length locking device automatically releasing itself after attachment, ensuring speed and reliability of operation. This unique "cone-latch" mechanism also overcomes the problems associated with having to remove pins or clips prior to starting a test, or tests being conducted with the extensometer accidentally locked at gauge length. Because of their larger frame size, the W-6280 series extensometers require two handed operation to attach the instrument to the specimen, so these extensometers still rely on a pin to set the gauge length. All extensometers except the W-6235 allow the ability to measure both positive and negative strain allowing compressive or flexural test measurements.The 2630 series and W-6280 series extensometers include different gauge length and strain range options to suit a wide range of specimen characteristics. All 2630 series and W-6280 series extensometers comply with both the ASTM E 83 and IS0 9513 standards, and gauge lengths are available in metric or U.S. customary units. Calibration certificates are supplied, showing the individual performance of each unit at its factory calibration.Static strain measurement on a wide range of materials and specimens including metals, plastics and composites.
-
product
Transverse and Diametral Extensometers
3 models cover most any test requirement and can be used with axial extensometers at the same time. Miniature and standard units, also r-value units. Available options cover temperatures from -265 to +200 C (-450 to +400 F).
-
product
High-Temperature Extensometers < 950 °C Capacitive
Is typically used in hot tensile applications with tube type furnaces and consist of a separate measuring unit and suspension arm assembly. The measuring unit uses an LVDT with a fixed travel that remains outside of the furnace, the arms are located mostly inside of the heating system and attach the specimen to the measuring unit.
-
product
Rugged, Long Gauge Length Extensometers
Model 3543
Jinan Testing Equipment IE Corporation
With over 15 years of proven reliability in the world’s most demanding testing environments, the Model 3543 extensometer is designed to survive in those applications where standard axial extensometers would not. Designed by Epsilon, the Model 3543 was created to survive specimen failure by separating into two halves, thus preventing permanent damage to the module body. During operation, the upper half of the extensometer pulls out of the main body. Tapered measuring beams activate strain gaged flexures within the unit. This unique design allows long measuring ranges, yet retains compatibility with electronics for strain gaged transducers. These models offer high accuracy and are light weight but rugged, with low operating force. They are tension only units.The units have hardened tool steel knife edges. Standard quick attach wires provided with the extensometer work on flat specimens up to 12 x 31 mm (0.5 x 1.25 inch) and on rounds up to 25 mm (1 inch) diameter. Optional quick attach kit wire forms are available for use on larger samples. See Model 3542L for long gauge lengths with smaller measuring ranges.The Model 3543 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Bi-Axial or Axial Averaging Extensometers
Model 3560
Jinan Testing Equipment IE Corporation
This extensometer is ideally suited for testing anisotropic materials such as advanced composites as well as for general purpose tests like determining Poisson’s ratio. The Model 3560BIA uses a design unique to Epsilon, where the knife edges remain parallel during the displacement. This approach greatly reduces crosstalk between axes and allows use on round or flat specimens with equal ease. These extensometers are very easy to mount. Integral springs hold the unit on the test sample. The parallel multiple flexure design makes these units very durable.The Model 3560AVG reads axial strain only as a single averaged output. It may also be supplied with two independent outputs, one measurement from each side of the specimen. This set-up is most commonly required when an indication of specimen bending is desired. The second version, the Model 3560BIA, includes both the averaged axial strain and the transverse strain. Again, this may also be configured as dual independent axial readings, which results in a three channel extensometer.The Model 3560 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
High Temperature, Low Strain, Extended Performance Capacitive Extensometers
Model 7650A
Jinan Testing Equipment IE Corporation
Model 7650A extensometers measure strains with extremely high precision due to their design features and low strain range. All models are capable of tension and compression strain measurement, and may be used for fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650A models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to provide high accuracy, high resolution measurements and perform high temperature fatigue testing at the highest possible frequencies. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods for specimen contact when testing to 1200℃ (2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.The Model 7650A is often customized for specific test needs. Contact Epsilon for a configuration that matches your requirement.
-
product
Diametral Extensometers for Rock and Concrete Testing
Model 3975
Jinan Testing Equipment IE Corporation
Designed for accurate measurement of small diametral strains such as those required to determine Poisson’s ratio of rock, concrete and asphalt samples. The units are designed to be used in conjunction with the Model 3542RA axial averaging extensometer.
-
product
Long Travel Extensometers
The first type is specifically aimed at the plastic and rubber industries to provide accurate readings of strain and extension over a large extension range. The unit, incorporating two clamping arms and precision potentiometers, produces a DC voltage proportional to the distance between the arms. This generates accurate readings of percentage strain and allows additional parameters such as yield point and break points to be calculated when used with NEXYGENPlus software.
-
product
Contactless Video Extensometers
Jinan Testing Equipment IE Corporation
Deformation measurement of samples during material testing with use of the Video extensometer MercuryRT allows applying multiple virtual probes (Movement Sensors)on markers and advanced image featuresto be tracked, including the natural pattern of the sample surfaces.The common resolution of standard system is within 500 nm and 5 m. The system fulfils class 0.5 or B-1 of classification according to ISO 9513 and ASTM E83. In certain camera use case, the system resolution reaches the level of 100 nm - 500 nm and system fulfils the class 0.2. The strain resolution can reach 10 microstrains. Material testing,Component testing ,FEA validation,Vibrography .
-
product
Axial Torsional Extensometers
Model 3550
Jinan Testing Equipment IE Corporation
Designed for simultaneously measuring axial and torsional deflections on specimens tested in axial/torsional machines.
-
product
High Temperature XY Planar Biaxial Extensometer 1200 C or 1600 C)
Model 7651
Jinan Testing Equipment IE Corporation
Model 7651 extensometers measure combined in-plane strains in flat cruciform specimens tested in machines capable of simultaneous X and Y (perpendicular) axial loading and on standard flat samples tested in pure tension. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7651 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to eliminate crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃(2900°F) high temperature option.
-
product
Miniature Averaging Axial Extensometers
Model 3442RA1
Jinan Testing Equipment IE Corporation
With gauge lengths of 1 and 2 inches (25 and 50 mm) and measuring ranges of 0.050 and 0.100 inches (1.2 and 2.5 mm), the Model 3442RA1 was designed for applications where tensile or compressive strength tests on small rock, concrete and other small compression samples is desired.
-
product
Video Extensometers
The VE1 is a high precision video extensometer that uses a non-contacting optical measurement based on a digital camera and real time image processing to measure the longitudinal and transversal strain during tensile tests.
-
product
Auto Calibration for Load & Extensiometer
Jinan Testing Equipment IE Corporation
TE electronic calibration module provides an easy way to calibrate load cell or extensometer and signal conditioning electronics without using a mechanical calibrator. It enables performing on-site electrical calibration and easy to periodically “spot check”, which will help ensure that the load cell and the extensometer and electronics are calibrated correctly.
-
product
High Temperature, Low Strain Capacitive Extensometers (1200 C or 1600 C)
Model 3648
Jinan Testing Equipment IE Corporation
These extensometers use a high temperature capacitive sensor in combination with an innovative design to achieve high accuracy strain measurements in low measuring ranges not possible with other high temperature extensometers. They mount on a slide bracket (included) that can attach to the load frame of your test system; optional load frame mounting brackets are available. The overall design reduces any influence from common lab environment vibrations.The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. These units are made to order in many different gauge lengths and measuring ranges.The extensometer comes with a signal conditioner. The output is an analog DC voltage, factory calibrated with the extensometer to 0 to ±10 VDC typically. They are readily interfaced with most existing test controllers, and may be directly connected to data acquisition systems and chart recorders. Bringing the signal into a spare DC input channel (or external input) on the test controller allows the extensometer to be used for strain controlled tests like low cycle fatigue.
-
product
Contacting Extensometers
AMETEK Sensors, Test & Calibration
The contacting extensometers are designed for accurate strain and extension measurement of a material up to a maximum sample thickness of 25 mm.
-
product
Fracture Mechanics Clip-On Gages
Model 3541
Jinan Testing Equipment IE Corporation
The Model 3541 is designed for determination of fracture mechanics parameters such as JIC, KIC, R-curve, fatigue crack growth rate (da/dN), and testing to standards such as E1820, E399, E647, etc. These COD gages conform to the requirements of E1820 (the replacement for E813 and E1737) for JIC and R-curve determination. Special configurations are available to meet the requirements of ASTM E399 for fracture toughness (please consult the factory for these configurations). In addition, the modified groove design complies with E1820 tests where greater stability and accuracy results from the sharper groove root. Clip-on gages are used for a variety of fracture mechanics tests, including compact tension, arc shaped, disk shaped, bend specimens or other specimen geometries in compliance with ASTM and other standards organization’s test methods. Clip-on gages can be used directly on test specimens where the knife edges are integral with the test specimen or, alternately, with optional bolt-on knife edges mounted on the test specimen.The Model 3541 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Automatic Extensometer
SIE-560A/560SA
To determine the suitability of a material for an application where it is under load, measuring its elongation is important. Measuring elongation enables determination of the elastic modulus (reversible elongation in the elastic region) by measuring the small initial elongation range, and determination of elongation at specimen failure, by measuring larger irreversible elongation in the plastic region. Shimadzu’s SIE-560A series automatic extensometers accomplish both of these measurements with high accuracy, and provide automated functions that increase testing efficiency and test reproducibility. Ideal for testing a wide variety of materials, including metallic materials, plastics, and composites, the SIE-560A series complies with ISO 527, JIS K 7161, and ASTM D638 standards for plastics tensile testing. In addition, the SIE-560A series supports strain-rate controlled metallic material tensile testing measurements specified in ISO 6892, JIS Z 2241, and ASTM E4
-
product
Automatic Contacting Extensometry
AUTOX750
Automatic contacting extensometers provide this capability by eliminating manual operator steps which can add time and introduce operator influence.
-
product
Axial Extensometers