Neutralize static charge.
-
product
Ionizers
ESD
Electrostatic discharge (ESD) is the release of static electricity when two objects come static control ESD IT-7000 Tabtop ionizerinto contact. Familiar examples of ESD include the shock we receive when we walk across a carpet and touch a metal door knob and the static electricity we feel after drying clothes in a clothes dryer. A more extreme example of ESD is a lightening bolt. While most ESD events are harmless, it can be an expensive problem in many industrial environments.
-
product
Charge Plate Monitors
Our easy-to-use charge plate monitors allow you to accurately evaluate air ionization systems used to neutralize static charge accumulation. Benefit from our economical solutions and products that offer onboard data storage to automate ionization system testing.
-
product
Pulse Air-Gun Ionizers
EC-G Series
Panasonic Industrial Devices Sales Company of America
With the new Pulse Air-Gun Ionizer from Panasonic, operators can comfortably neutralize static electricity while manually cleaning. The Pulse Air-Gun’s light-weight, ergonomic design combined with an oil and heat-resistant 2m cable makes it ideal for use at the production line.The Air-Gun Ionizer is equipped with a white LED on the front of the Gun to illuminate target objects. It has three air emission modes: long pulse, short pulse and continuous emission. Ionized air can be emitted at high pressure (range 0.05 to 0.50 MPa), neutralizing static charges and removing dust simultaneously and swiftly.
-
product
Radius Radiation Probe
Hawk Radius®
The Hawk® Radius is a ruggedized solution for monitoring both ambient and elevated levels of ionizing radiation. Like a Hawk with its remarkable vision, the Hawk Radius Probe “sees” things that other probes cannot. The high sensitivity weatherized pancake sensor can provide early warning of changing ambient radiation conditions, while the energy compensated detector can accurately report penetrating gamma radiation dose rate at elevated levels. Radius probes are typically deployed as part of an environmental radiation monitoring program, or for safety and security systems. In its standard configuration the probe detects beta, low energy gamma and x-radiation with one channel and energy compensated penetrating gamma radiation levels with a second channel. It can be configured to detect alpha radiation as well. The Hawk® Radius has been deployed worldwide in demanding conditions for protecting communities and collecting environmental radiation data. It can be deployed easily and requires minimum maintenance. The Radius is compatible with Medcomʻs GeigerLink adapter and the IMI Gateway App for use with personal computers. It can also be used with most data loggers including popular Campbell Scientific models.
-
product
Mass Spectrometry
SQ Detector 2
Compatible with the broadest range of chromatography platforms and ionization sources, the SQ Detector 2 is the ultimate single quadrupole mass detector for chromatography.
-
product
Flame Ionization Detector
A flame ionization detector converts a hydrocarbon gas concentration into an electrical signal. The flame is hydrogen fueled and burns in hydrocarbon free combustion air. Either side of the flame are two electrodes between which an electric field is generated by means of a polarization voltage. The sample is pre-mixed with the fuel gas and heated in the flame to a temperature at which the hydrocarbon molecules ‘crack’ and CH fragments appear. These CH fragments are oxidated by the oxygen in the combustion air resulting in the formation of CHO+ ions. The ion current then passes to the electrodes and the resulting current measured is proportional to the quantity of C atoms derived from organic compounds.The Thermo-FID features two separate microprocessor controlled pressure compensations to avoid any influence from environmental or sample conditions. In addition, the complete Thermo-FID range of analyzers are equipped with a flame trap that is used as a heated sample inlet filter. The measurement chamber and all material in contact with the sample gas are heated between 120°C and 200°C to avoid condensation.
-
product
Radiation Detectors
A radiation detector is a device for measuring nuclear, electromagnetic or light radiation. A nuclear radiation detector identifies nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a geiger counter, a nuclear radiation detector consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or nuclear radiation detector.
-
product
Geiger Counters
A geiger counter detects nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a radiation detector, a geiger counter consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or radiation detector.It is very important to measure radioactivity as well as to classify radioactivity values. For example, terrestrial gamma radiation is measured according to general values from 0.03 - 0.3 µSv/h (microsievert / hour). This "normal" oscillation range is conditioned by natural radioactive elements in the ground such as uranium and potassium. To calculate this factor, one must take into consideration cosmic radiation. For example, when considering cosmic radiation, the maximum radioactivity content at Schneefernerhaus, the highest-located German environmental research station, is approximately equal to 110 µSv/h.At PCE Instruments, you will find three types of geiger counter or raditation detection devices to help you measure radioactivity: 1) alpha radioactivity meters, 2) meters for detecting alpha, beta and gamma radioactivity and 3) radioactivity meters for human beings.
-
product
Other Environmental Testers
GAOTek’s environmental testers can be used to measure parameters such as humidity, temperature, wind speed or velocity, wind direction, air quality, electromagnetic waves, ionizing radiation and more. Environmental testers are applicable in climate monitoring to occupational health and safety (OHS) applications. Our environmental testers are useful tools for collecting data about the immediate surroundings. Depending on the model, an environmental tester can function as a data logger for long-term data by collecting and storing measurement data over a certain period. Our environmental test solutions are affordable and dependable and are perfect for general to specialized jobs.
-
product
Radiation Meters
A radiation meters is a device designed for measuring varying types of radiation. These devices are portable and are used to inspect personnel, equipment, and facilities for radioactive contamination by measuring the emission of certain radiation particles. They are used to measure external or ambient ionizing radiation field to assess the direct exposure hazard.
-
product
Walker Test Set
PGA-710B
A unique electrostatic data analysis device for use with Prostat’s PFK-100 Field meter/Charge Plate Monitor Set.• Records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltageretention, ionizer performance and other static measuring functions.• Creates detailed reports to help determine the risk of equaling or exceeding damaging or hazardous HBM dischargevoltages in static sensitive facilities.• Analyze Footwear & Flooring Combinations: Records personnel walking voltages in accordance with ANSI/ESD STM97.2 Body Voltage measurements as required by ANSI/ESD S 20.20 ESD Program Standard• Other Equipment Applications include voltage generation of chairs, carts and process equipment
-
product
Tabletop Ionizing Transport System
90610-03610
The Model IT-7000 Ion Transport System is a self contained, compact table top ionizer capable of producing copious amounts of both positive and negative ions. The variable speed fan permits a gentle flow of ionized air, reaching a distance of up to 4 feet. A charged object, when passed through the ionization field, becomes neutral instantaneously. Inherently balanced, the Ion Transport System has a fail safe balance indicator to assure proper ionization output for ESD static control applications.
-
product
Test Line • Equipment For Testing For Function
The test equipment is used for qualitative functional testing of discharge power supply units and / or ionization units from the static line and air line (discharge). The devices are usually operated with a single button and indicate via LED, whether the device under review functions properly.
-
product
Blood Ionized Calcium Pocket Water Quality Meters
LAQUAtwin Ca-11C
Milk fever, or Sub Clinical Hypocalcemia (SCH) is a significant problem with dairy cows. Total calcium levels in the cows’ blood drop after lactation. By measuring the ionized calcium levels of the blood directly cow side, the treatment can start sooner and is more effective. The new LAQUAtwin CA-11C has been specially developed for cow side measurement of ionized calcium in blood. Ionized calcium reflects more accurately the current calcemic blood situation compared to total blood calcium as it equals the free available calcium ions.
-
product
Rapid Evaporative Ionization Mass Spectrometry
REIMS
The innovative iKnife hand-held sampling device produces information-rich vapor directly from the surface of the sample, which when analyzed by a time of flight (Tof) MS, provides analysts with an accurate molecular profile in seconds.
-
product
Radiation Microdosimeters
Teledyne e2v HiRel Microdosimeter is a compact hybrid microcircuit which directly measures total ionizing dose (TID) absorbed by an internal silicon test mass. The test mass simulates silicon die of integrated circuits on-board a host spacecraft in critical mission payloads and subsystems. By accurately measuring the energy absorbed from electrons, protons, and gamma rays, an estimate of the dose absorbed by other electronic devices on the same vehicle can be made. The Microdosimeter can operate from a wide range of input voltages. The accumulated dose is presented to three dc linear outputs and one pseudo-logarithmic output giving a dose resolution of 14 µrads and a measurement range up to 40 krads. These outputs are intended to be directly connected to most analog-to-digital converters (ADCs) or spacecraft housekeeping analog inputs (0-5 V range), which makes minimal demands on the host vehicle. The Microdosimeter incorporates a test function to allow electrical testing of the hybrid without the need for a radiation source.
-
product
Static Meters
ETS static meters are offer accurate detection and measurement of static electricity found in the manufacture and handling of electronic, paper, plastic, textile, food, chemical, biomedical, and pharmaceutical products. In addition, these meters are invaluable for use in computer rooms, cleanrooms, hazardous environments, hospitals, and other locations that require the measurement of electrostatic fields. Chopper-stabilized models enable measurements in ionized environments.
-
product
Electrostatic Field Meter - Hand Held Field Meter for Locating and Measuring Electrostatic Field Density
PFM-711B
- Lightweight, portable, hand-held Field Meter- Measure in 1 volt/in increments 0 to ±1,999 Volts- Measure in 10 V/in increments 0 to ±20,000 VoltsAccuracy of <±5%- LED ranging lights help position the meter at the right distance- Zero button allows the display to be adjusted to zero (0)- Hold feature freezes the measurement on the display- Use with Prostat CPM-720B Charge Plate Monitor and PCS-730B Electrostatic Charger- Use with Prostat PGA-710B AutoAnalysis System or X-Y Plotter- Analyze Footwear/Flooring Combinations- Verify Ionizer Balance and Decay Time Performance- 2-year Limited Warranty (1 year on the sensor)
-
product
Fan Type Ionizer
ER-F
Panasonic Industrial Devices Sales Company of America
With a compact size of 150 x 166 x 62mm and a fan of 120mm in diameter, the ER-F Fan Type Ionizer belongs to the leading class of compact Fan Type Ionizers. The system employs a high-frequency AC method and boasts a +/-2kV discharge output voltage that discharges electrostatic contaminated objects quickly and safely. Louvers for long distance and wide area applications are shipped with the Ionizers. Standard fan types for faster charge removal times and low-volume types for discharging small parts or film are available.
-
product
Digital Ionizing Radiation Detectors
All the numerous features of the SEI Inspector USB wrapped up in a rugged protective boot. For surveys in the field or on the move, this is a great option to protect your detector.
-
product
Ionization bars
Wolfgang Warmbier GmbH & Co. KG
Suitable for down-stream applications ie "laminar airflow boxes"Air assistance for various applicationsComplies with IEC 61340-5-1 Ed. 1.0 (2007-08)Pulsed AC high voltage IonizationEach tip emits positive and negative ionsSelf-balancing ± 30VControl input and alarm output connectorPower supply 230V / AC via controllerOne controller is suitable for two ion barsAdjustments on controller sideEasy emitter replacement
-
product
Analog Ionizing Radiation Detectors
A great general purpose analog radiation detector. Detects from 0-50 mR/hr.
-
product
Charge Plate Monitor
The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.
-
product
Static Sensor
718
Portable Meter for Testing of Electrostatic FieldsMeasures surface voltage and polarity on objects up to ±19.99 kV at a distance of 1 inchSwitch Selectable Measurement RangesProvides readings from 0 to ±1.999 kV and 0 to ±19.99 kVChopper-Stabilized Probe TechnologyAllows for use in ionized environmentsDurable Dissipative Housing Design with Membrane SwitchesProtects meter from physical damage and minimizes wearLED Range FinderRed ranging lights help operator to place the meter at the correct distance from the object being measuredHold ButtonAllows the measurements to be retained for easy reading and extends battery life
-
product
Hydrocarbon Instruments
Teledyne Advanced Pollution Instrumentation
Teledyne API has developed a hydrocarbon instrument using patented gas chromatograph (GC) technology, in combination with well-characterized and familiar Flame Ionization Detection (FID). This instrument uses a new modular hardware and electronics architecture which is the basis for Teledyne API's new N Series platform. The instrument platform is thoughtfully designed for reliability, ease of operation and maintenance, low power consumption, and advanced communications and diagnostic capabilities.
-
product
Static Field Meters and Ionization Test Kits
Portable Meter for Testing of Electrostatic FieldsMeasures surface voltage and polarity on objects up to 19.99 kV at a distance of 1 inch.Durable Dissipative Housing Design with Membrane Switches (NEW)Protects meter from physical damage and minimizes wear.LED Range FinderRed ranging lights help
-
product
AOI Handlings System
The AOI handling system is a compact facility with various test units. Via an ionization cleaning station the ceramics are transferred to the contacting station. There, the resistance values of the substrates are tested with a rigid needle adapter. Afterward, the ceramics are further conveyed to the three (optionally four) AOI test stations (for automatic optical inspection) and are tested for cracks, unevenness, faulty imprints, contamination, etc. The poorly evaluated ceramics arrive at a review station where the operator can assess and evaluate the errors on the monitor. If the operator is uncertain about a fault, the ceramic in question can be positioned under the microscope position and inspected by eye. Poorly defined ceramics are marked accordingly with an ink pen.
-
product
Thin-Type Ionizers
ER-VW Series
Panasonic Industrial Devices Sales Company of America
The Panasonic ER-VW Thin-Type Ionizer uses high frequency AC in an ultra-thin Ionizer for superior static elimination.
-
product
Autoanalysis System Set
PGA-710B
The PGA-710B is a unique electrostatic data analysis device for use with Prostat's PFK-100B Field Meter and Charge Plate Monitor kit. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions.
-
product
Professional Floor Certification Kit
PFC-252
The PFC-252 includes Prostat's PRS-812 Resistance System Set with modified 5 pound conductive rubber electrodes and Prostat’s Cable Spacers for exact measurements. The PRS-812 wide range resistance system can take measurements at 10 and 100 volts with accuracy within ±5%. Also included is the PFK-100 Field Meter Set. The PFK-100 set includes Prostat's unique PFM-711A dual range field meter, CPM-720A charged plate monitor assembly and PCS-730 ±1 kv charging source. With this instrument set you can measure electrostatic fields, analyze ionizer performance and assess the voltage generation of materials, equipment and personnel.