Filter Results By:
Products
Applications
Manufacturers
Luminance
The photometric measure of luminous power.
-
product
Isolation Amplifier Digital Output
This coupler is an optically coupled isolation amplifier that uses an IC with a high-accuracy sigma-delta A/D converter and a GaAIAs light-emitting diode with high-speed response and high luminance efficiency on the input side, and an IC with a digital signal (MDAT, MCLK) output function on the output side. This coupler is designed specifically for high common mode transient immunity (CMTI) and high linearity (nonlinearity) applications, making it ideal for current sensing in motor drives.
-
product
Universal Instrument for Measurement
MI-6201 Multinorm
Universal all-in-one instrument for measurement of air temperature, air velocity, relative humidity, illuminance, luminance and the Class 1 (Pro Set) or Class 2 (Euro Set and Standard Set) sounds analyses.
-
product
High Power LED Photo-color-semi Automatic Selector
Shenzhen Chuangxin Instruments Co., Ltd.
Can divide LED in to several groups by chromatic coordinates, correlated color temperature, dominant wavelength or luminous flux.
-
product
Ambient, Seat, & Stowage Lighting
The Carat® Light Nuancia system is an intuitive way to illuminate your cabin environment. The Nuancia system lets you choose from two different ways to light areas in your customers’ desired color. This lighting system enhances all furniture inside any aircraft from seats to monuments. The Nuancia lighting solution offers the most flexible and adaptive ambient lighting system by displaying variable colors and luminous intensity while focusing on reliability.
-
product
Spectroradiometer
Spectroradiometer is usually used with a integrating sphere to measure the photometric and colorimetric parameters of all kinds of lamps. Relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature Tc, color rendering index Ra, dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, SDCM, luminous flux, etc.
-
product
2D Video Luminance Meter
LS-ELF
LS-ELF can record 15 frame’s 2D luminance data per second. Also LS-ELF can record the image while driving 60-80km/h speed. It can be used in many fields as Display, Light pollution, Lighting, Lab, etc.
-
product
Light Meters
TES Electrical Electronic Corp.
Dual Display, 4 digit LCD reading.Spectral Sensitivity close to CIE phototropic curve.Measuring levels ranging 0.001 to 1999kAccurate and instant response. Luminance ratio A/B
-
product
LED Fast-Scan Micro-Spectrophoto Colori meter
8000
Shenzhen Chuangxin Instruments Co., Ltd.
The system can determine spectral power distribution, chromaticity coordinates, correlated color temperature, color rending index (Ra), color difference, peak wavelength, spectral half width, dominant wavelength, color purity, luminous flux, test for photometry colorimetry electricity of LED characteristics.
-
product
Integrating Sphere
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
product
High Precision Rotation Luminaire Goniophotometer
LSG-1800B
LSG-1800B Goniophotometer is automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800B use a constant temperature detector, Japanese Motor and Germany precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Goniophotometer Test System For Led Lamp
1680A 1680B
Shenzhen Chuangxin Instruments Co., Ltd.
Design according to IEC61341,the test method of central luminous intensity and beam angle for reflecting light, this instrument can be used to test the cross section luminous intensity distribution curve, central luminous intensity and effective beam angle of LED assembled luminaries and LED lens system with diameter less than 180mm.
-
product
Rotation Luminaire Goniophotometer
LSG-1800
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Light-resistant Integrating Sphere
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
product
PCE Series Opto-Electric Measurement System
Hangzhou Everfine Photo-E-Info Co., LTD
This system delivers various photometric, colorimetric and electrical parameters as required by CIE standards.Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
-
product
All Digital Luminance-Meter
Xinye Optoelectronic Engineering Co.,Ltd.
Designed to measure luminance and chromaticity of light sources.
-
product
Imaging Colorimeters and Photometers
Are well designed to handle a large variety of applications and functions. They utilize rapid capture technology to get a complex reading of color distributions and luminance very quickly. Additionally, their imaging photometers are extremely accurate.
-
product
Goniophotometer for Traffic Signal Lamps
LSG-1950S
LSG-1950S is a high automatic test system for luminous intensity distribution of luminaires and can be applied to quality evaluation and quality control for signal luminaires, luminaires for cars, motors, vessels and Retro-reflectors. LSG-1950S system is a goniophotometer which can measure all kinds of lamps and luminaires.• Rotations of test samples around both vertical axis (-90°~+90°) and horizontal axis (-35°~+35°) • Accuracy of angle: 0.1° • Resolution of angle: 0.01° • Photometer detector: CIE class A (standard class) accuracy • All software control, high intellectual faculties and simple operation
-
product
Near-field Goniophotometer
RiGO801
TechnoTeam Bildverarbeitung GmbH
Correct determination of the luminous intensity distributions (lid) of lamps and luminaires far within their photometric near-field range. Capture of ray data.
-
product
Luminance Meters
Konica Minolta Sensing Americas, Inc
Luminance meters are single element detectors that measure photometric brightness. The Konica Minolta luminance meter measures the amount of emitted or reflected light from a surface. These instruments display luminance in either cd/m2 or foot-lambert (ft-L) and they are lightweight, compact and portable. They can be connected to a PC which can store the measurement data and control the device. The LS-160 has a single lens reflex optical system to precisely measure very small (0.4mm) diameters at very short distances, making it extremely easy to use.
-
product
Spectroroadiometer
SR Series
Spectroradiometer "SR series" can measure spectral, luminance and chromaticity with high accuracy.
-
product
LED Goniophotometer For Led Tester
CX-880
Shenzhen Chuangxin Instruments Co., Ltd.
880 LED Test machine is used to measure: 1.the luminous intensity dirstribution curve, 2.intensity data, 3.spread angle and equivalent luminous flux of small lamps.
-
product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
Rotation Luminaire Goniospectroradiometer
LSG-1800CCD
LSG-1800CCD/LSG-1700CCD Goniospectroradiometer is an automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800CCD can do the spatial CCT test when do the intensity distribution test. It is for industrial laboratory measurements the photometric data of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
product
Luminance Colorimeter
BM Series
There are various lineups such as hand-held type and measurement of ultra low luminance in short time.
-
product
Display Measurement Systems
DTS Series
Instrument Systems Optische Messtechnik GmbH
Characterization of emissive, transmissive, reflective, and transflective displaysViewing-angle-dependent analysis of illuminance, contrast, color, and derived parametersDetermination of the electro-optical transfer function: analysis of luminance, contrast, and color depending on electrical driving conditionsMeasurement of transient properties, such as switching times, flicker, and modulation
-
product
Goniophotometer
GMS2000
In this goniophotometer, the tested luminaire rotates in the prescribed burning position and around the vertical axle and a reflecting mirror rotates around the horizontal axle, meanwhile, a synchronous axle will rotate toward the opposite direction synchronously. The combined motion of the luminaire and mirror permit luminous measurement at the direction of any horizontal or vertical angle without tilting the luminaire, therefore, the luminous intensity will be not variation. The photometer head located at a fixed position of the limiting photomet- ric distance in front of the reflecting mirror to gather the light in each direction.
-
product
Photometric Probes for Illuminance
LPPHOT03… Series
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.
-
product
DC Power Supplies for Precision Plating
R4GT Series
These are applicable to tests for luminous elements, LED, organic electroluminescence (OEL), etc. which handle minute current. Superior usability is realized with equipped FINE function which can set quickly voltage and current. Moreover, as these correspond to digital communication, applicable widely from experiments to automation line.
-
product
Poly
Measurement functions for air temperature, air velocity, relative humidity, illuminance and luminance are all found within one device.