Filter Results By:
Products
Applications
Manufacturers
Partial Discharge
voltage discharge within an insulator causing dielectric breakdown.
See Also: Partial Discharge Detection, Partial Discharge Monitors, PD, PD Test, Partial Discharge Test
-
product
Partial Discharge Meter
TMG
The partial discharge meter TMG was developed for Partial Discharge tests according to VDE 0434 and IEC 60270.
-
product
Partial Discharge
Partial discharge (PD) is a local electrical discharge that occurs in imperfections or inhomogeneities. The partial discharge measurement is a so-called “non destructive test” to determine the quality of insulating materials. On the contrary of pure high-voltage test, th test item is not pre-damaged at low PD levels.
-
product
Real-Time Online Monitoring to Detect and Analyze Potential Partial Discharge (PD) Signals and Insulation Faults using UHF, AE, and HFCT
PDMonitor
Power Monitoring and Diagnostic Technology Ltd.
The PDMonitor, which utilizes Ultra High Frequency (UHF), Acoustic Emission (AE) and High Frequency Current Transformer (HFCT) sensors and is designed to conduct real time online monitoring to detect and analyze potential Partial Discharge (PD) signals and insulation faults before they lead to breakdown or catastrophic failure in power assets. The system provides the developing trend of the PD, when occurring, as alarms in real time, thus helping to predict the insulation degradation status of the asset, prevent sudden accidents, and provide an effective database for Condition-Based Maintenance (CBM) of power assets.
-
product
Conventional Power Supply Design with Simple Analog Controls
VLF Series
VLF hipots perform voltage withstand tests and provide the voltage source for diagnostic cable testing. There is no better method for verifying the AC integrity of a cable than applying VLF AC voltage. Tan delta and partial discharge measurement accessories are frequently purchased along with VLF equipment to extend their capabilities.
-
product
Partial Discharge Tester
19501-K/19500
Chroma 19501-K partial discharge tester combines hipot test and PD (partial discharge) detector functions in one instrument. The device is capable of a maximum 10kV AC output with leakage current measurement range of 0.01uA and a minimum partial discharge detection of 1pC. The tester is specifically developed to test high voltage semiconductor components and high insulation materials.
-
product
Compact Ultrasonic Testing Device
SONAPHONE® Pocket
With the SONAPHONE Pocket you identify problems even before they arise and create value at all levels of your company. Just by detecting and eliminating leaks you can reduce the energy costs for your compressed air system up to 30 percent. This also has positive effects on your operational safety and system productivity through early warning of bearing failure and evidence of partial electrical discharges.
-
product
TEM Antenna
TEM antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset (like MV switchgears or LV and MV induction motors fed by power electronic impulses). It is a broadband antenna with a flat response which makes TEM suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes TEM the optimal sensor for direct installation on medium voltage Switchgears and motors. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces.
-
product
Portable Switchgear Partial Discharge
PD-SG1
The PD-SG1 is a dual transducer Switchgear PD detection instrument. The unit detects TEV signals generated by internal discharge, as well as acoustic discharge generated by surface tracking or corona.
-
product
Substation Series Testers
GTPD-92
Partial discharge(PD) is a pulsed discharge that produces a series of physical phenomena and chemical changes such as light, sound, electrical and mechanical vibrations in and around electrical equipment.
-
product
Partial discharge measurement with remote wireless reading
PD-LT
The PD-LT allows online partial discharge detection on cable accessories such as cable head for safety and maintenance purposes.The PD-LT indicates the intensity of the partial discharges, converting the electrical charge units (pC) into decibels (dB). Thus the reading is kept as a simple intensity level indication, proportional to the probability of a fault's presence in the tested medium voltage accessory.The remote display gives a dB value of the probe's measurement. The dB value will vary along with the discharges indicators on the PD-LT probe. The measurement range is from 0 to 65dB and the display will show ''OL'' if the reading is over 65dB.
-
product
Online PD Spot Tester
Liona
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR liona. Liona is a portable online PD spot tester for measuring and locating partial discharges in cables and switchgear during normal mains operation. Liona lets you test cable systems and electrical equipment online without switching off partial discharge activities, and then generate trend analyses. Even a PD spot test (duration: 5-10 minutes) is capable of reliably assessing the current status of your system.* Automatic PD detection during normal mains operation (without switching off the cable route)* With DeCIFer technology: PD identification based on 500 million measurement results* Precise online PD mapping with PD transponder
-
product
Handheld PD Tester
Weshine Electric Manufacturing Co., Ltd
TEV partial discharge inspection instrument uses two emerging technologies, transient-to-ground voltage (TEV) measurement and ultrasonic (US) measurement, to detect faults in switchgear. The equipment is portable and easy to operate. The TEV sensor is attached to the wall of the box, and the US sensor scans and detects along the gap on the switch cabinet.
-
product
Transformer Testing And Monitoring
Can detect the symptoms of transformer failure by monitoring the cooling system, load tap changer, dissolved gas, bushing power factor and capacitance, partial discharge, oil levels, pressure, temperatures and more.
-
product
Spiral Antenna
UHF Spiral antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset. It is a broadband antenna with a flat response which makes Spiral antenna suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain.
-
product
Portable PD Analyzer
AQUILA
A compact and portable Partial Discharge acquisition unit, which allows to detect and analyze partial discharge activities in all electrical assets: from power cables to transformers, rotating machines and switchgears, together with the right combination of sensors and accessories. AQUILA comes with a full range of options, ideal for field testing.
-
product
UHF PD Detector
Handheld online PD substation surveying system. The UHF PD Detector is the ideal tool for quick, non-invasive surveys in MV and HV substations and should be part of the toolkit for all maintenance and service teams. Due to its high measurement bandwidth, the UHF method provides accurate local online partial discharge (PD) measurements on HV components such as cable end-terminations, surge arrestors, voltage transformers and isolators.
-
product
Inductive Sensor
HFCT Ø 30-39-50mm
Techimp HFCT is an inductive sensor for partial discharge measurements. It is suitable for on/off line PD tests on many electrical systems (cables, transformers, rotating machine, etc..). It has to be applied to the ground connection of the system to be tested.
-
product
High Frequency Current Transformer
HFCT
The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.
-
product
Dielectric Loss Tangent Testing Instruments
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
product
Partial Discharge Test System
TPP
The Partial Discharge Test System type TPP is used for non-destructive insulation and quality testing of electrical components (for example according VDE 0110-1, EN 50178, IEC 60270 and IEC 60060).
-
product
Partial Discharge Measuring Equipment
Different from a conventional partial dischargemeasuring set provided with a fixed testingfrequency, Model DAC-PD-5 is newly designed toselect the center and the bandwidth of testingfrequencies so that partial discharges emitting in anoptional frequency in the range of a specifiedbandwidth can be detected. Generally, partialdischarges are measured in a wide band frequencythough; the detecting sensitivity must be lowered inorder to detect partial discharges partially.DAC-PD-5 has a wider bandwidth and can measurepartial discharges in a high sensitivity by bypassingnoises emitting bands.
-
product
Partial Discharge Expert Diagnostic and Location System
PDExpert
Power Monitoring and Diagnostic Technology Ltd.
The PDExpert is PMDT's third level of Partial Discharge (PD) Expert Diagnostic and Location System. It is a powerful, portable, multi-channel system of impeccable design used to analyze and pinpoint PD signals coming from a power asset within centimeters while the power system is energized. The system consists of UHF, AE, HFCT and ultrasonic sensors, one advanced UHF/PD signal processing unit, one oscilloscope, filters and other accessories.The system employs ultra-high speed data acquisition and advanced digital signal processing technologies, compares the UHF, AE and HFCT signals of different frequency ranges to determine if it is PD or noise, and locates the source in power assets accurately by utilizing Acoustic-Electromagnetic Combination Location Technique, time Difference of Signals' Arrivals (TDOA), and 3D Positioning Technology.
-
product
Partial Discharge Surveyor
PDS100
The Doble PDS100 Partial Discharge Surveyor is a radio frequency interference (RFI) surveying tool that is designed for use in a live substation.Without the need for outages, the PDS100 can detect partial discharge (PD) in just a few seconds making it an ideal tool for a condition based maintenance program.
-
product
Partial Discharge Measurement Calibrator
DAC-CP-2
DAC-CP-2 is a calibrator for partial discharge measurements. The electric charge enables to generate up to max 10000pC. It is battery-operated and can be charged by connecting to the measuring instrument (DAC-PD-3).
-
product
Lightning Rod Flaw Detector
PADD
We developed the PADD for the detection of internal and external partial discharges on metal oxide lightning rods. Defects can cause radio interference in communication systems or TV images, interference whose origin is very difficult to locate. We have developed a unique technology for detecting radio frequencies for use under voltage.
-
product
Ultrasonic Leak Detection Camera
Leakshooter LKS 1000-V.2
1st ultrasonic compressed air, gaz and vacuum leak detector with camera. Specialy dedicated to visualize the spots where compressed air is leaking, the LEAKSHOOTER LKS 1000 – V.2 has many other applications such as : steam trap monitoring, bearing monitoring, electrical applications like partial discharge, corona effects, punctured isolators, electrical tracking detection.
-
product
Partial Discharge Tester
GTPD-2C
GTPD-2C Digital partial discharge tester is the digital partial discharge measuring and analyzer adopting the complete new generation technology. It is suitable for partial discharge detection in manufacturing factory and field handover test of transformers, generators, CT/PT, bushings, GIS, capacitors, power cables, switches and other high-voltage electrical equipment with various voltage levels and capacities.
-
product
Partial Discharge
Is a localized dielectric breakdown (DB) (which does not completely bridge the space between the two conductors) of a small portion of a solid or fluid electrical insulation (EI) system under high voltage (HV) stress.
-
product
Partial Discharge Measuring Equipment
Electro Mechanical Enterprises
Partial discharge instruments have two modes of Wide Band and Low Frequency. You can use it for Partial Discharge tests of High-Voltage Equipment, Insulation Materials, High-Frequency Equipment, and Power Semiconductor devices. Partial discharge Measuring Equipment can easily realize the test of Partial discharge on print-circuit boards, connectors, semiconductors, small motors and other insulation materials, to make a judgment on good / bad of them
-
product
Partial Discharge Detector
JFD-2000A
Wuhan Huatian Electric Power Automation Co., Ltd.
It is suitable for local discharge measurement of all kinds of high voltage electrical equipment and represents the advanced technology of domestic digital local discharge instrument.