Filter Results By:
Products
Applications
Manufacturers
VOC
biochemicals which readily evaporate at room temperature.
See Also: Volatile Organic Compound, Indoor Air Quality
-
product
Sensor Solutions for IoT
Imec is a reference in the design of ultra-low power electronics, low-power algorithms to increase intelligence and data security, and in all aspects of data science. Our multi-sensor environmental monitoring platform features sensors for temperature, relative humidity, NO2, CO2, VOC (volatile organic compounds), particle matter, ambient light, sound, vibrations and presence detection. Our test platform is suitable for indoor and outdoor air quality monitoring and control, and can be used in smart buildings, smart cities and more.
-
product
Environment click
Environment click measures temperature, relative humidity, pressure and VOC (Volatile Organic compounds gases). The click carries the BME680 environmental sensor from Bosch. Environment click is designed to run on a 3.3V power supply. It communicates with the target microcontroller over SPI or I2C interface.
-
product
Chemiluminescence 03 Analyzer
Model T265
Teledyne Advanced Pollution Instrumentation
The Model T265 is the only commercially available US EPA Federal Reference Method for Ambient Ozone Monitoring according to the latest US EPA regulatory rules for O3. The instrument uses Chemilumescence with Nitric Oxide (NO) as a reagent, making is safe, stable, and effective for all applications. The NO-CL method for Ozone has several advantages over the conventional UV absorption technology, including the avoidance of positive and commonly found interferrents such as VOCs, fine particulates, Mercury, turpines, ClO2, and others. If these pollutants are present in the atmosphere, it can cause UV absorption analyzers to give an artificially high Ozone measurement. The innovative T265 combines speed of response, sensitivity and stability of our proven nitrogen oxide analyzer, with a simple user interface, to provide reliable ozone measurements under the harshest conditions.
-
product
Air Quality Meters
An indoor air quality meter is used in confined spaces to prevent mold, to monitor CO2 levels, or to detect gas leaks. Whether portable or fixed, handheld or wall mounted, air quality monitoring equipment is essential for ensuring health and safety. At PCE Instruments, you will find air quality monitoring devices that meet various industry standards relating to personal safety and that are used to detect, measure and monitor relative humidity, ambient temperature and / or levels of carbon dioxide (CO2), volatile organic compounds (VOCs), formaldehyde (HCHO), freon and other refrigerants (CFC / HFC), phosphine (PH3), hydrogen sulphide (H2S), carbon monoxide (CO), nitrogen dioxide (NO2), oxygen (O2), ozone (O3) and other flammable, hazardous or toxic gases.
-
product
CO2 meter alarm
VAT820-CO2
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Indoor air quality monitor :CO2 monitor , indoor air quality including CO2,VOC temperature ,humudity
-
product
Volatile Organic Compound VOC Meters, Monitors
For handheld and long-term VOC measurement and logging.
-
product
GC Sample Prep & Sample Introduction
For Gas Chromatography Preparation & Introduction, Teledyne LABS’ brand offers Purge & Trap instruments to prepare samples for separation. P&T is routinely applied to detect volatile organic compounds (VOCs) down to sub-ppb levels in soil and water, and as a step in determining outdoor and indoor air quality. The arrival of microprocessor-driven systems allows the concentrator to be more precise and automated, giving the operator more time for other projects. All Teledyne LABS P&T instruments satisfy U.S. Environmental Protection Agency method guidelines.
-
product
Air Quality
Controlling IAQ is critical to maximizing building performance and occupant health/safety. ACI sensor solutions for IAQ include VOC and PM (volatile organic compound and particulate matter), CO2 with options to fit every application.
-
product
Vehicle Interior Air Quality Testing
Underwriters Laboratories Inc.
Hundreds of volatile organic compounds (VOCs), which off-gas from the materials and finishes used in car interiors, can be present in the air inside a new vehicle. VOCs can cause odor complaints and have been linked to numerous health concerns. As the demand for healthier products increases, vehicle manufacturers that tell a compelling sustainability story can capitalize on a significant opportunity to grow market share. UL helps manufacturers capture value for their sustainability efforts, mitigate risks and comply with increasingly complex regulations.
-
product
Solar Array Simulator
62000H-S series
The latest programmable solar array simulator power supply 62000H-S Series released by Chroma provide simulation of Voc (open circuit voltage) up to 1800V and Isc (short circuit current) up to 30A. The 62000H-S provides an industry leading power density in a small 3U high package. The solar array simulator is highly stable and has a fast transient response design, which are both advantageous to MPPT performance evaluation on PV inverter devices. The 62000H-S Series have many unique advantages including high speed & precision digitizing measurement circuits with a 100kHz A/D, 25kHz D/A controlled I-V curve and a digital filter mechanism. It can simulate an I-V curve accurately and response the mains ripple effect from the PV inverter. In addition, the built-in EN50530/Sandia SAS I-V model in the standalone unit can easily program the Voc, Isc, Vmp, and Imp parameters for I-V curve simulation, without a PC controller.
-
product
CDPH Standard Method for VOC Emissions
Underwriters Laboratories Inc.
The Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions From Indoor Sources Using Environmental Chambers, an expanded standard for what is commonly known as California Specification 01350, is one of the most widely used standards to evaluate building and interior products for low chemical emissions.
-
product
Solar Array Simulator DC Power Supply
62000H-S
Chroma Systems Solutions, Inc.
Solar Array Simulator DC Power Supplies by Chroma provide programmable simulation of Voc (open circuit voltage) up to 1800V and Isc (short circuit current) up to 30A. The 62000S-H series provides an industry leading power density in a small 3U high package. The Solar Array Simulator is highly stable and has a fast transient response design, which are both advantages to MPPT performance evaluation on PV inverter devices.
-
product
Infrared Camera for Methane and VOC Detection
FLIR GF300
The FLIR GF300 detects methane, other hydrocarbon, and volatile organic compounds resulting from the production, transportation, and use of oil and natural gas. This camera can scan large areas and visualize potential gas leaks in real-time, so you can check thousands of components over the course of one survey. Designed with the user in mind, the GF300 is lightweight, offers both a viewfinder and LCD monitor, and has direct access to controls.
-
product
Power Meters and Calibration Cells
The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.
-
product
Trace VOC Analyzer
PTR-TOF 6000 X2
The new PTR-TOF 6000 X2 is our premium PTR-TOF trace VOC analyzer. We conceived a unique system comprising of a novel high-resolution TOF and IONICON’s PTR technology with the new “X2” features, for the ultimate PTR-TOFMS experience. X2 combines the latest generation of performance enhancing tools incl. the ION-BOOSTER funnel as well as the hexapole ION-GUIDE. The ion funnel focuses the ions into the hexapole ion guide which results in nearly lossless transmission of an extremely focused ion beam into the TOF mass spectrometer. This increases the sensitivity dramatically and also improves the instrument’s mass resolving power. Utmost resolution, sensitivity and lowest real-time detection limit are now available in a robust, transportable platform that is smaller and lighter than previous products.
-
product
Acrylic Buttons
VAT810-TH/SD (VAT810-CO2)(VAT845
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Desktop:Touch buttons : CO2 monitor Real-time monitoring of indoor air quality including CO2,temperature ,humudity and VOC.
-
product
Ambient Pressure Photoemission Spectroscopy With Nitrogen Environment
The APS04-N2-RH incorporates a tuneable deep ultra-violet (UV) source outputting 3.4 - 7.0 eV, for absolute work function and highest occupied molecular orbital (HOMO) measurements, a surface photovoltage spectroscopy (SPS) module outputting 400 - 1000 nm for Voc and Eg measurements, together with a 50 x 50 mm scanning area for planar relative work function measurements (Fermi level).
-
product
EQE/Photon-Electron Conversion Testing
Enlitech offers different solutions for incident photon-electron conversion testing systems. The available systems include IPCE, PV External quantum efficiency (PV-EQE), Internal Quantum Efficiency, Spectral Response (SR), Highly-sensitive EL-EQE. There are over 1,000 SCI papers cited Enlitech‘s systems to provide reliable experimental data for significant scientific publication. The Highest PV-EQE sensitivity and EL-EQE both reach 10-5 % (7 orders). They can be utilized to PV conversion efficiency, HJT/ PERC/TOP-CON current-loss analysis, Organic PV charge-transfer-state and Perovskite PV trap state measuring, and Organic PV and Perovskite PV Voc loss analysis.
-
product
MCCI Catena® 4460 Sensor Wing w/ BME680 VOC Sensor for LoRaWAN™ Technology
The MCCI Catena® 4460 Sensor Wing is a flexible open-source IoT device wing designed specifically for use with the Adafruit Feather M0 with LoRa® radio system, but suitable for use with any Adafruit Feather CPU board. Like the Catena 4450, when combined with a suitable CPU, it is a ready-to-use platform for LoRaWAN™ 1.0 and 1.1 wireless IoT applications.
-
product
Environment Click
64205
The Environment click module measures temperature, relative humidity, pressure and VOCs (Volatile Organic compounds gases).
-
product
Trace Gas Analyzer
PTR-TOF 4000
The new PTR-TOF 4000 is a compact, ultra-sensitive & high-resolution IONICON PTR-TOF real-time trace VOC analyzer. It is our first high-resolution PTR-TOFMS built into the same small and lightweight layout known from our successful PTR-TOF 1000 series. It also features the new hexapole ION-GUIDE technology for increased sensitivity and resolution. The PTR-TOF 4000 thus allows you to benefit from both high mass resolving power and high-sensitivity. Like the other instruments built on this platform also the PTR-TOF 4000 demonstrated its reliability and robustness but also its remarkable technical abilities and speed during various international campaigns (e.g. NASA's KORUS-AQ).
-
product
Indoor Multi-Light source of Measurement System for PV Cell
King Design Industrial Co., Ltd.
The multi-light source measurement system is capable of execute I-V measurements by Real-Time One-Sweep Method (RTOSM), which not only removes the capacity effect but also meets the requirements of SEMI PV57-1214. The measurement process is controlled by designed program, thus the measured I-V curve, Pmax/Isc/Voc/… etc, could be exported automatically.This system is applicable to DSSC/OPV/Perovskite measurements.
-
product
Fault Detection Device in PV String
Hanwa Electronic Ind. Co.,Ltd.
◆Very light and easy to carry.◆Possible to find fault areas that can’t find by Voc.◆Measurement Voc and Vc.◆Possible to check data and record the data using Android.
-
product
Gas & Emissions Analyzer
Si-CA 8500
Accurate, reliable, robust & fast, the Si-CA 8500 Combustion Analyzer is the most powerful and advanced portable emissions analyzer on the market. Complete portable tool for emissions level monitoring of boilers, engines, and other combustion equipment, this emissions monitoring device can boast as many as 9 gas sensors, detecting one of the widest spectra of gases: O2, CO, NO, NO2, SO2, CO2, CxHy, High CO, VOCs and H2S.
-
product
IAQ Meters
General offers five indoor air quality (IAQ) instruments that measure and track four key IAQ parameters: Carbon monoxide, carbon dioxide and two toxic gasesformaldehyde and volatile organic compounds (VOCs). The last two substances have made news lately for their ubiquity, invisibility and toxicity.
-
product
Multi-Matrix Purge and Trap
Atomx XYZ
The Atomx XYZ is the second generation combined soil/water autosampler and purge and trap concentrator system in the Tekmar VOC product family. It is the only instrument of its kind to employ a unique automated methanol extraction feature for high level soils in accordance with USEPA Method 5035. Methanol rinsing, dilutions capability and three standard addition vessels all come standard on the Atomx XYZ. While priced competitively, the system offers unique features that cannot be found on any other sample prep system on the market today.
-
product
VOC Detectors
The Baseline® VOC-TRAQ® II detector is a handheld VOC sensor designed for ease of use and is an excellent way to monitor and record PID detectable total volatile organic compounds (TVOCs), whether you are an air quality consultant, safety engineer, maintenance manager, or just concerned about TVOCs in your environment. This Baseline VOC detector includes:
-
product
Air Quality USB Dongle
UTHINGL::VOC
uThing::VOC™ is a USB dongle useful to quickly integrate or evaluate the Bosch BME680 air quality sensor. If you need to sense air-quality data and decide to use the Bosch BME680, you will find that integrating the Bosch proprietary algorithms is not a trivial task, and that the code size limits its use in constrained platforms like many Arduino boards.