Filter Results By:
Products
Applications
Manufacturers
-
product
SENSORBOX MODULE
MDGDSSBM
*Turn your MDMAX, MDMAX2A or MDMAX3 into a unique sensor simulator to substitute known good waveforms for intermittent components that cannot be verified*Sensor simulation tests include: DC voltage, fixed frequency, pre-defined waveform and hand-drawn waveform*Contains a library of standard reference waveforms that can be modified by the stroke of a finger
-
product
Three-phase Fully Automatic Test System
TS41
Calmet Smart Calibration Devices
The Calmet TS41 test system consists of a three-phase reference meter of accuracy class 0.02% (or 0.04%) and an integrated three-phase current and voltage source up to 3x120A/600V. It makes possible automatic testing of electricity meters in meter test stations
-
product
Load Cell Power Supply
MODEL PSMR
The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.
-
product
Software
Junction Measurement and Analysis
Materials Development Corporation
A comprehensive set of analyses for junction diode or Schottky barriers begins with C-V data gathering that adjusts the voltage step to the slope of the C-V characteristics. This assures an optimum set of C-Vdata whether the voltage range is small or large. Doping profile and resistivity profile are both available at the touch of a key. Plots of 1/C2 - V or Log(C) - Log (V+ phi) show doping uniformity and doping slope factor. Exclusive recalculation options allow adjustment of stray capacitance and area to facilitate calibration using a standard reference wafer of known doping or resistivity.
-
product
Low Power Potentiostats
Potentiostat Wenking MP 04T, max. current 400 mA, max. voltage 25 V, output power 10 W, reference electrode input 1012 Ohms, slew rate 10 V/ µs, 1 control input, floating current output, buffered potential output, control range ± 10 V external, internal control voltage source ±2 V, rise time constant (closed loop, ohmic load) 1 µs typ., dimensions 165 x 105 x 165 mm (w x h x d), weight 1.4 kg
-
product
Signal Analysis
Harmonic Distortion Analysis
The software is used for automatic measurement of the harmonic distortion factor and voltage r.m.s. of signals coming to the input channels of FFT spectrum analyzers. Adjustment to the frequency of the main component is performed automatically. The program is based on the measurement of the voltage r.m.s. of higher components by an external or internal reference signal.
-
product
ATE For ADC Module
MS 1527
The Semi-ATE is used for testing the analog ADC. It shall carry out the functional test on ADC analog module. The ATE shall have all necessary IO signals on the connector end. The semi-ATE can carry out the functional tests on ADC analog module with host PC or laptop. It provides +15V, -15V, +5V & -5V to module and +2.5V high precision reference voltage. It can able to control keysight N6700B Power supply mainframe using RS422 interface.
-
product
Optical Chopper
SR540
Stanford Research Systems, Inc.
The SR540 chopper will handle all your optical chopping requirements?from simple measurements to dual-beam and intermodulation experiments. The SR540 has a 4-digit frequency display, front-panel frequency control, analog voltage frequency control and two reference outputs with selectable operating modes.
-
product
Precision Resistor Network
Analog Devices provides a portfolio of quad resistor networks with excellent matching specifications over the entire temperature range. All of our resistors can be accessed and biased independently, making them a convenient and versatile choice for any application that can benefit from matched resistors. Our resistor networks provide the precise ratiometric stability required in highly accurate difference amplifiers, voltage references, and bridge circuits.
-
product
Single Channel Potentiostats
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
product
Data Converter ICs
We offer a complete range of high-performance, low-power,and small-size data converter integrated circuits (ICs) for demanding industrial, automotive and consumer applications. Whether you need an Analog-to-Digital Converter (ADC), Digital-to-Analog Converter (DAC), digital potentiometer, AC and DC power and energy measurement device, voltage reference or a combinationof data converter ICs, we have the right solution for your application and world-class support to make sure you meet your design goals.
-
product
DC - 400 MHz PC-Based Timer Interval Analyzer
GuideTech’s GT658PCI is an ultra-fast, high resolution, DC – 400 MHz Time Interval Analyzer (TIA), ideal for most PC-based lab bench (timing) test applications. What makes the GT 658 superior to traditional counters is analogous to the difference between volt meters & digital scopes. While both measure voltage, the scope provides much more information about the dynamics of the signal. This is because our patented TIA substantially increases measurement speed, and the measurements are displayed as afunction of time. All of these features, along with the benefit of ‘continuous time correlation to a common reference between all measurement time stamps,’ enable our TIAs to make measurements that weren’t previously possible with traditional counters.
-
product
300nA NanoPower Voltage References
ISL21080
The ISL21080 analog voltage references feature low supply voltage operation at ultra-low 310nA typ, 1.5µA max operating current. Additionally, the ISL21080 family features guaranteed initial accuracy as low as ±0.2% and 50ppm/°C temperature coefficient.
-
product
Signal Conditioners
General Purpose
Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.
-
product
Rad-Hard Analog ICs
ST's wide range of rad-hard QML-V qualified analog ICs covers analog-to-digital converters (ADC) and digital-to-analog converters (DAC) for telemetry, instrumentation and imaging applications. Our portfolio also includes rad-hard op amps, high-speed differential amplifiers up to 1 GHz, shunt voltage references and comparators to ensure a complete solution for signal conditioning, referencing and data conversion.
-
product
Shunt Regulators
These are the standard reference voltage source widely used by the feedback circuits of switching power supplies. Compared to the Zener diode, which is a discrete product, a shunt regulator has much better voltage precision because voltage control is carried out as an IC.
-
product
Linear IC Tester
570A
The Model 570A Analog IC Tester's built-in test library includes all common Analog ICs including op-amps, comparators, voltage regulators, voltage references, analog switches & multiplexes, opto-isolators & couplers, and audio ICs.
-
product
RF COMPONENTS
If space is an issue and you are looking for high quality RF Components, ETL's wide range is designed and manufactured at the ETL factory. Covering DC to 40GHz, these are at the heart of many of our 19" Rack Systems.A key feature of many of ETL components is the ability to pass or block a 10 MHz signal or DC voltage through the products, which can be used to power interconnecting components or pass a stable frequency reference to a LNB or BUC within the system.
-
product
Single Phase Reference Standard Meter
Signals & Systems India Private Limited
The Single Phase Portable Reference Standard (SPRS-1102) from SANDS is a portable meter test equipment that helps to calibrate the error present in the single-phase energy meter i.e. the meter under test (MUT). The SPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, phase angle etc of the meter under test. It has an LCD display and an alphanumeric keypad to suit the user. It can be interfaced with the PC for analysis. It has the capability of storing 1000 test results.
-
product
Series Voltage References
Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.
-
product
Digital Multimeters
Multi-Display : Primary 80000, Secondary 80000, Bargraph 23 SegmentsBasic DC Accuracy : 0.05% mV Impedence : > 1000M OhmMore than 50 Measuring FunctionsFrequency Measurement : 0.5Hz to 8.0000MHz 16 Frequency Points, 1% to 99% Duty. Selectable Square Wave OutputAnalyzing Component of Current or Voltage SignalResistance : 0.1Ω to 80MΩ, 10MΩ to 8000MΩCapacitance : 1nF to 100µFTemperature : -50°C to 1372°C, -58°F to 2502°F dBm 20 Types of Reference ImpedenceAuto Data Hold / Peak HoldRelative Measurement36 Hours Dynamic Recording : MAX / MIN / AVG/ MAX-MINCommunication : Isolated Optical RS-232Timer for MeasurementBacklight DisplayAuto Power Off
-
product
VME Analog Output Module
DP-VME-2115
DP-VME-2115 is an industrial standard 24 channel D/A (Digital to Analog) board. It incorporates most of the features which are demanded in industrial applications. Each Digital to Analog Converter (DAC) is provided with a separate reference voltage selection either from internally generated reference or from the external input. This external input reference signal is passed into the protection circuits before it is fed to any active components. The input protection circuit is designed for ± 25Vp-p input ranges. The DAC output may be unipolar or bipolar and the output is jumper selectable, which is routed to the VME P2 connector, with short circuit protection of upto 30mA.
-
product
Three Phase Portable Energy Meter Calibration Equipment
GF302D1
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
product
Phase ID Systems
LED Meter Probe allows the user to take Real time Phase Angle readings along with AC nominal voltage readings. A PD800W LED Meter Probe works in conjunction with the Receive Unit to verify phase identification along with the actual phase angle data. This is all done without any calculations or data transfer from the field to a base computer. The meter probe and reference probe or receive unit can operate at 100 feet of separation and up to 300 feet line of sight separation. In the event that this distance would need to be greater, the Receive Unit can be unplugged from the charging cable and taken into the field while operating on it's rechargeable batteries for up to 8 hours at a time.
-
product
Dual Channel HV Amplifier with Phase Inverter
A400DI
This unit contains two independent A400 amplifiers that share common ground reference and power supply. Please see A400 page for technical details.It features also a low voltage phase inverter that inverts the signal applied to the input of channel 1. The resulting signal can then be connected to the input of channel 2 by means of a short BNC cable (supplied). As a result the two outputs operate in counter-phase. Connecting a load between the outputs effectively doubles the amplitude range. Please note that the load cannot have any connection to ground.
-
product
Thermocouple Vacuum Gauge Tubes for Medium Vacuum
DV-6 Series
Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-6 series thermocouple vacuum gauge tube acts as a localized sensor which is then paired with a selection of meters or controllers to provide reliable, cost-effective measurements in diverse applications. The robust sensor gauge tube is easily installed into vacuum systems and when properly excited, generates a thermoelectric voltage to provide a vacuum pressure measurement based on gas density. The DV-6 thermocouple vacuum gauge tube fully compensates for temperature and rate of temperature change.Thermocouple gauge tubes are calibrated on vacuum systems that contain N2 or Air, but can be used with other gases. Additionally, thermocouple gauges and their controllers can be recalibrated when a replacement thermocouple gauge tube is installed, following instructions in the manual. However, our DB-20 reference tube is available to confirm meter/controller performance. A complete line of installation accessories are also available to simplify the integration of our thermocouple gauge tubes into a variety of vacuum systems. Our goal is to provide “one less thing to worry about”, when performance matters! With a wide range of meter, fitting, relay and output options, the DV-6 series provides a reliable pressure measurement in numerous industries and applications.
-
product
Three-phase Fully Automatic Test System
TS33
Calmet Smart Calibration Devices
The Calmet TS33 portable test system consists of a three-phase reference meter of accuracy class 0.02%, 0.04% or 0.1% and an integrated three-phase current and voltage source up to 3x120A/600V. The TS33 is designed for analysis of complete metering installations and local mains conditions.
-
product
Oscilloscope App
Oscilloscope for iOS is great for analyzing audio range signals, or learning oscilloscope measurement basics. The interface includes many standard oscilloscope controls, such as: triggering, time and voltage per division, signal measurement cursors, and more. The app incorporates a signal (function) generator capable of generating sine, square, triangle, and sawtooth waveforms of up to 22 KHz. Calibration to an external reference signal is supported, guaranteeing the accuracy of measurements.
-
product
Instrument Transformer
CT & PT Test Equipment
Measurements International Ltd.
Calibration of Voltage and Current Transformers from a Single Instrument, Calibration of Instrument Transformers with Different Rated Ratios Using One Single Reference Standard, Calibration of Voltage Transformers (VT) up to 800 kV When Used with MI 2500 Series of HV Dividers and Standard Capacitors, Calibration of Current Transformers (CT) Up to 10000 A When Used With MI 7020 and/or 7200 Series of Precision Current Transformers and/or Current Comparators, Test Frequency from 15 Hz to 100 Hz70.
-
product
PXI Millivolt Thermocouple Simulators
Series 41-760
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channelseach channel providing a low-voltage output across two connector pins capable of providing 20mV with 0.7V resolution, 50mV with 1.7V resolution and 100mV with 3.3V resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor.