Teledyne Advanced Pollution Instrumentation
Teledyne API (TAPI) designs and builds precision air quality and industrial gas monitoring instrumentation at our factory located in San Diego, California, USA. Our products are used worldwide in ambient air quality monitoring systems (AQMS), continuous emissions monitoring systems (CEMS), and industrial process applications.
- (858) 657-9800
- (858) 657-9818
- api-sales@teledyne.com
- 9970 Carroll Canyon Road
CA, San Diego 92131
United States of America
-
Product
High Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200H
-
Teledyne Advanced Pollution Instrumentation
The Model T200H combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. A high-efficiency stainless steel thermal NO2 converter provides durable and consistent operation under the harshest conditions (other converter options also available).The T200H may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.
-
Product
Nitrogen Compound Instruments
-
Teledyne Advanced Pollution Instrumentation
Teledyne API produces a wide range of instruments for the measurement of Nitrogen compounds, including those that measure 'True NO2'. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring
-
Product
Portable Zero Air System
Model 751H
-
Teledyne Advanced Pollution Instrumentation
The Model 751H is a portable, fully self-contained source of high purity zero air for dilution calibrators. It is ideal for use with sensitive analyzers in ambient background and trace level applications. Packaged in a wheeled, high density plastic case, the Model 751H provides ultra-high purity output with a warm-up time of 30 minutes.
-
Product
Dissolved Ozone Instruments
-
Teledyne Advanced Pollution Instrumentation
For measuring dissolved ozone concentrations in water a microprocessor controlled instrument can be used for automatic and continuous measurement by means of an disinfectant sensor. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
Product
Process Ozone Sensor
Model 452
-
Teledyne Advanced Pollution Instrumentation
The Model 452 is a microprocessor based gas sensor for measuring high concentrations of ozone in oxygen or air with accuracy and dependability. The measurement principle is based on the absorption of UV light at 254nm. Readings are available in % by weight, or grams/Normal cubic meter. Temperature and pressure compensation up to 3 Bar Absolute is a standard feature.
-
Product
High Range Chemiluminescence NOX-NO2-NO Analyzer
Model N200H
-
Teledyne Advanced Pollution Instrumentation
The Model N200H uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of high-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
Product
UV Absorption O3 Analyzer
Model T400
-
Teledyne Advanced Pollution Instrumentation
The Model T400 UV Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air.A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of ozone present. Periodically, a switching valve alternates measurement between the sample stream and a sample that has been scrubbed of ozone. The result is a true, stable ozone measurement.
-
Product
Gas Calibrators and Zero Air Generators
-
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.
-
Product
Photolytic True NO2/NO/NOx Analyzer
Model T200P
-
Teledyne Advanced Pollution Instrumentation
The Model T200P provides measurements of NO and NO2 using our Model T200 NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.In the photolytic process the sample gas passes through a cell where it is exposed to light at a specific wavelength from an LED array. This causes the NO2 to be selectively converted to NO with negligible interference from other gases. Advances in the photolytic converter technology now yields NO2 conversion efficiency that is similar to molybdenum under typical ambient NO2 concentrations, but without the same interferences.
-
Product
Trace Level Portable Gas Calibrator
Model T750U
-
Teledyne Advanced Pollution Instrumentation
The Model T750U is a portable, microprocessor based calibrator for precision trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.
-
Product
CAPS True NO2-NOX-NO Analyzer
Model N500
-
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
Product
UV Fluorescence TRS Analyzer
Model T102
-
Teledyne Advanced Pollution Instrumentation
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
-
Product
High Range UV Fluorescence SO2 Analyzer
Model N100H
-
Teledyne Advanced Pollution Instrumentation
The Model N100H instrument uses the proven UV fluorescence principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of high range SO2 gas. The instrument includes interferent rejection, providing a simple and precise solution for a broad range of continuous emission monitoring systems (CEMS) and stack testing applications.
-
Product
Trace-Level Dilution Calibrator
Model T700U
-
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
Product
CAPS Trace-Level NO2 Analyzer
Model T500U
-
Teledyne Advanced Pollution Instrumentation
The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package.The T500U provides a direct NO2 measurement, eliminating the need for catalytic conversion or reagents which introduce measurement artifacts inherent in traditional heated metal converter based chemiluminescense instruments. The CAPS measurement approach also reduces maintenance items, and removes the need for hazardous materials and high temperature scrubbers within the instrument. The T500U has an expected maintenance interval of one year under typical ambient monitoring conditions.