Teledyne Advanced Pollution Instrumentation
Teledyne API (TAPI) designs and builds precision air quality and industrial gas monitoring instrumentation at our factory located in San Diego, California, USA. Our products are used worldwide in ambient air quality monitoring systems (AQMS), continuous emissions monitoring systems (CEMS), and industrial process applications.
- (858) 657-9800
- (858) 657-9818
- api-sales@teledyne.com
- 9970 Carroll Canyon Road
CA, San Diego 92131
United States of America
-
Product
Non-Dispersive Infrared Monitors
OPTI-Sense Series
-
Teledyne Advanced Pollution Instrumentation
The OPTI-Sense series of sensors is based on Non-Dispersive Infrared (NDIR) technology. They are designed to precisely measure the absorbance in the infrared spectrum of specialty gases typically found in semiconductor applications. They are very compact and designed with no moving parts, making the OPTI-Sense robust and ideal for continuous in-situ gas monitoring of semiconductor processes.
-
Product
Chemiluminescence NH3 Analyzer
Model T201
-
Teledyne Advanced Pollution Instrumentation
The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter (see "Features" tab for external converter photo) to give stable and repeatable NH3 measurements at very low levels. In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations. The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units. Optional zero and span valves allow automatic, unattended calibration checks.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model T360M
-
Teledyne Advanced Pollution Instrumentation
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.
-
Product
Process Ozone Instruments
-
Teledyne Advanced Pollution Instrumentation
All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring. Below is a list of a range of Teledyne API process ozone instruments.
-
Product
Trace Level Chemiluminescence NO-NOy Analyzer
Model T200U NOY
-
Teledyne Advanced Pollution Instrumentation
The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.The Model T200U NOy analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer. The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters. In addition, the converter features a unique purge circuit designed to remove residual calibration gas.
-
Product
Portable Trace-Level O3 Calibrator
Model T753U
-
Teledyne Advanced Pollution Instrumentation
The Model T753U is a portable, microprocessor based precision Calibrator for Ozone gas instruments and sensors. Using a sophisticated Ozone generation system, combined with a sensitive photometer and pneumatic design, the T753U produces stable and reliable concentrations of Ozone in a convenient and rugged package based on our popular T750U Portable Multigas Calibrator platform. The T753U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field for virtually any application. An internal zero air option extends the T753U's capabilities to also provide a clean and dry source of zero air, eliminating the need for a separate source of zero air. The internal zero air source module contains a software driven electronic inlet valve manifold allowing the calibrator to automatically switch between internal and external zero air sources depending on the application needs.
-
Product
Chemiluminescence 03 Analyzer
Model T265
-
Teledyne Advanced Pollution Instrumentation
The Model T265 is the only commercially available US EPA Federal Reference Method for Ambient Ozone Monitoring according to the latest US EPA regulatory rules for O3. The instrument uses Chemilumescence with Nitric Oxide (NO) as a reagent, making is safe, stable, and effective for all applications. The NO-CL method for Ozone has several advantages over the conventional UV absorption technology, including the avoidance of positive and commonly found interferrents such as VOCs, fine particulates, Mercury, turpines, ClO2, and others. If these pollutants are present in the atmosphere, it can cause UV absorption analyzers to give an artificially high Ozone measurement. The innovative T265 combines speed of response, sensitivity and stability of our proven nitrogen oxide analyzer, with a simple user interface, to provide reliable ozone measurements under the harshest conditions.
-
Product
Oxygen Compound Instruments
-
Teledyne Advanced Pollution Instrumentation
Teledyne API’s range of instruments for Oxygen compounds utilize advanced technology to produce some of the most accurate measurements available.All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
Product
Trace-Level UV Fluorescence SO2 Analyzer
Model T100U
-
Teledyne Advanced Pollution Instrumentation
The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.
-
Product
Gas Measuring Instruments
N Series
-
Teledyne Advanced Pollution Instrumentation
N Series Gas Measuring Units for SO2 (Sulfur Dioxide), NO, NO2, NOX (Nitrogen Oxide, Nitrogen Dioxide), CO (Carbon Monoxide), CO2 (Carbon Dioxide), O3 (Ozone), True, Direct NO2, NOX, NO, CH4 (Methane), THC (Total Hydrocarbons), and more
-
Product
Chemiluminescence NO/NO2/NOX Analyzer
Model T200
-
Teledyne Advanced Pollution Instrumentation
The Model T200 NO/NO2/NOx analyzer uses the proven chemiluminescence detection principle, coupled with state-of-the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS monitor.A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while advanced Adaptive Filtering allows the analyzer to optimize performance under changing conditions. The Model T200 includes a permeation inlet dryer for ozone generation to provide excellent reliability with no periodic replacement required. A catalytic exhaust ozone scrubber is standard for maximum safety and pump life.
-
Product
Gas Filter Correlation CO Analyzer
Model N300
-
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Trace-Level Chemiluminescence NO/NO2/NOx Analyzer
Model T200U
-
Teledyne Advanced Pollution Instrumentation
The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.
-
Product
Mid-Range Gas Filter Correlation CO Analyzer
Model N300M
-
Teledyne Advanced Pollution Instrumentation
The Model N300M is a microprocessor-controlled analyzer used to determine the concentration of carbon monoxide (CO) in a sample gas. The analysis method is based on the Beer-Lambert law.The N300M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Ozonator Controller
SCI-552
-
Teledyne Advanced Pollution Instrumentation
The SCI-552 is a system controller for ozone delivery systems that provides electronic control interfaces for a number of typical system components, including: ozone generators, EV valves, mass flow controllers, back-pressure controllers, Teledyne API 452 ozone sensors, Teledyne API 470 dissolved ozone sensors, and a water chiller.