Techimp HQ S.r.L
Strongly committed to innovation and research, Techimp (TECHnological IMProvements) Company stands for excellence in the field of innovative diagnostic technologies applied to electrical engineering.
- +39 051 199 86 050
- +39 051 199 86 099
- sales@techimp.com
- Via Toscana 11/C
Zola Predosa (BO), IT 40069
Italy
-
Product
TD Guard
-
TD Guard Intelligent Sensor is an on-line CONTINUOUS Capacitance and tan-δ monitoring system for transformer bushings. TD Guard Intelligent Sensor is the first and only instrument on the market providing absolute Tan-δ measurement in on-line permanent monitoring of transformer bushings, granting the best level of diagnostic leverage and reliability. Sensitivity better than 10-4.
-
Product
Inductive Sensor
HFCT Ø 30-39-50mm
-
Techimp HFCT is an inductive sensor for partial discharge measurements. It is suitable for on/off line PD tests on many electrical systems (cables, transformers, rotating machine, etc..). It has to be applied to the ground connection of the system to be tested.
-
Product
HV Test bench
-
It is a deeply customizable test bench which is suitable to generate frequency and amplitude controlled voltage. This test bench could be used for life test or quality test on samples or devices. It can be configured both for sinusoidal test (STANDARD version) and both for square wave or pulse test (TechSQUARE). It includes safety systems for avoiding overload and incorrect use.
-
Product
PPS Clamp Transformer
-
PPS2 provides power supply to the PD detectors installed on HV cable when low voltage AC power is not available. The PPS2 takes the required power directly from the High Voltage power line under monitoring by means of units clamped on the HV power cable(s).PPS2 is designed to withstand High Voltage line failure events such as temporary overload and short circuit conditions. An internal detection and self limiting circuitry guarantees that PPS2 and the connected equipment survives in case of such events.
-
Product
Spiral Antenna UHF Trafo
-
UHF Spiral antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset. It is a broadband antenna with a flat response which makes Spiral antenna suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes Spiral antenna the optimal sensor for direct installation on high voltage Transformers. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces. Contact our sales department for consulting.
-
Product
Solution for Industrial Monitoring
PDScope
-
Techimp PDSCope is a brand new product of the PDCheck family particularly designed to suit all the requisites of the Techimp TiSCADA systems for on-line monitoring of diagnostic quantities in electrical assets.Techimp PDSCope is a powerful PD analyzer based on Techimp TF Map technology (patented) allowing preliminary noise rejection and automatic calculation of statistical parameters relevant to Partial Discharges.
-
Product
Horn Antenna
-
Horn antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in electric assets like GIS and GIL or MV and HV power transformers. It is a broadband antenna with a flat response which makes Horn antenna suitable in a number of different applications. It has been optimized to operate in a frequency range suitable for PD activity monitoring and it was designed to provide maximum sensitivity and high gain.
-
Product
Space Charge Measuring Equipment
PEA
-
The increasing request for energy quality and, thus, insulation system reliability, associated with significant steps in the manufacturing of new insulating materials, are pushing strongly the research on new techniques for the diagnosis of insulation ageing.
-
Product
Complete Network Monitoring
TiSCADA
-
After years of advanced Research, laboratory and on-field tests, Techimp has developed powerful and effective tools which can help asset managers to take critical decisions and manage power plants in a cost saving ways. Ti-SCADA implements a Real Time condition control of your asset, through a powerful Human Machine Interface (HMI) fully configurable, web based, displaying graphs, charts, trends, KPI, historical data, alarms and customizable reports. Ti-SCADA is a fundamental component of the new generation of Techimp on line condition monitoring systems. Ti-SCADA is designed as a Service Oriented Architecture (SOA) based on interoperability standard for industrial automation - OPC-UA - allowing high performance asset management solutions, tailored on customer needs, to be implemented.
-
Product
PD Coupler
-
Techimp Capacitive PD Couplers offer both the PD and sync signals references, allowing a thorough investigation of the signal originating inside the asset they are connected to.Techimp Couplers are individually tested according to the following international standards: IEC60358; IEC60694; IEC60270.
-
Product
Tap Adapter
-
Techimp Voltage Tap Adapter is gender changer which allows the user to connect to the test tap (sometimes called power factor tap) of high voltage transformer bushings.While keeping the test tap well below the safety voltage level required by the manufacturer, the Tap Adapter lets the user to drain high frequency PD signals for diagnostic assessment of insulating materials.A synchronization signal can be derived as well.It is suitable for both single shot as well as continuous PD monitoring.Although it must be customized on the basis of the shape and dimension of the test tap (to be provided by the Customer), many models are readily available for the most established transformer bushings. A list of the presently available models is reported below.Several thousands of hours of operation are a guarantee of reliability and accurate design.
-
Product
Qualification and Quality Control Tests
Techsquare
-
New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.
-
Product
Spiral Antenna
-
UHF Spiral antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset. It is a broadband antenna with a flat response which makes Spiral antenna suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain.
-
Product
NLFA Notch
-
The NLFA is a multiple element device allowing several useful field configurations. The three internal elements,one low frequency amplifier, two notch amplifier each with the cut off freq. of 50Hz (or 60Hz for a specific version) can be used as independent ones or combined together to increase the notch function. The effect of the cascade of two notches is the increasing of the signal attenuation for the notch frequency.
-
Product
PDBase II
-
Even very skilled operators will find hard to make a diagnosis, in situations as the one mentioned above, through a mere visual evaluation of the pattern graph . Techimp new technology bases itself on the principle that efficient separation and identification of PD data can be achieved collecting PD pulses themselves and not only, as digital instrumentation commonly available does, PD pulse peak and phase.















