product
HVAC Pressure Transmitter
DP850/851
The DP850/851 transmitters are designed for low pressure measurement in HVAC applications. The DP850 is available in full scale pressure ranges as low as 0.25 inH2O and the DP851 can be ranged to 0.025 inH2O full scale. Both models are available in 4-20 mA or 0 to +5 Vdc signal output options.
-
product
Single-Channel USB Carrier Demodulator
CD17
The Validyne model CD17 is a USB-powered carrier demodulator for Validyne variable reluctance pressure sensors such as the DP15, DP45 and DP103. The CD17 allows any Validyne variable reluctance sensor to be used directly with a PC via the USB port. Communication and power via USB interface provides remote zero and span adjustment as well as digital pressure readings in mV/V. Drivers and software for the USB interface are included.
-
product
Pressure Transducers with CAN Bus Interface
P66
The Validyne model P66 is a digital differential pressure transmitter designed for industrial pressure measurement applications. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication via CAN Bus provides remote zero and span adjustment as well as digital pressure readings in engineering units or pressure counts.
-
product
Test and Measurement Grade Vacuum Pressure Transducer
P897V
The P897V is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover. The P897V is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor. Small vacuum pressures are accurately measured with full scale vacuum ranges as low as 2.22 InH2O.
-
product
Digital Display for the Transducers and Transmitters
PS57
The PS57 is a combination power supply and 4 1/2 digit LED display for the P55/P855 family of pressure transducers and transmitters. The PS57 accepts 110 VAC power and provides the required 24 Vdc excitation for the transducer. The transducer signal is received and displayed directly in engineering units with bright 0.56 high red LEDs. The user can re-scale the display and set the decimal point by configuring internal jumpers. The analog output of the transducer, 5 Vdc or 4-20 mA, is available on rear-panel terminals.
-
product
Ultra Low Pressure Transmitter
P532
Validyne's P532 Pressure Transmitters are ideally suited for measuring extremely low liquid and gas pressures in industrial applications. Full-scale differential pressure ranges from 0.10 H2O to 2 H2O with line pressure rating of 100 psig, and ranges of 2 H2O to 3200 psid with line pressures up to 3200 psig are offered. Gauge pressure ranges start at 0.10 H2O and absolute pressure from 0.08 psia full-scale. This unique design, which utilizes a diaphragm-type variable reluctance pressure sensor, provides many outstanding advantages including:
-
product
Draft Range Trasmitter
DR800
The Validyne Model DR800 Draft Range Transmitter is designed exclusively for very low pressure measurement needs. It has a "true" full-scale range as low as 0.25" H2O, making it ideal for air flow control applications. It can be turned down to 0.1" H2O; higher full-scale ranges to 100" H2O are available. The DR800 offers 0.5% accuracy and an operating temperature range of -20F to +185F. The total combined temperature effects are less than 3%/100F.
-
product
Pressure Sensor Kit for Changing Ranges
DP15TL
The wide range of diaphragms furnished eliminates expensive stocking of several transducers and offers the versatility of the differential type bi-directional transducer at a very low cost. The broad line pressure capability of this unit makes it useful in almost every laboratory application from flow to level measurement, vacuum to 3000 PSIG. The high output, when used with a carrier system such as the Model CD15 Sine Wave Carrier Demodulator or the CD12 Transducer Indicator, provides resolution equal to many secondary standard units.
-
product
Variable Reluctance Pressure Sensor with All-Welded Construction
DP10
The DP10 Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full scale output of 30 mV per volt at 3kHz. The unit operates with carrier system including the Validyne CD15 since wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator.
-
product
High Line Pressure Transducer
P365
The P365D transducer is designed to make low differential pressure measurements at high static line pressures. Operating from unregulated 9 to 55Vdc, the P365D is available with 4-20mA, 5Vdc or isolated 5Vdc output over full scale pressure ranges from 8 to 10,000 psid. The output shift due to static pressure will not exceed 3% of full scale, up to a line pressure of 10,000 psig.
-
product
Multi-Channel Carrier Demodulator
CD280
The CD280 Carrier Demodulator is a complete multi channel system in a small package which houses a plug-in power supply and 4 carrier demodulator circuit boards. The power supply provides regulated 5 Vac 5 kHz carrier power for Variable Reluctance and LVDT transducers , and the carrier demodulators demodulate and amplify the input signals to a 10 Vdc full-scale output. Zero and span adjustments are available for each channel. The system operates from 115 Vac, 50 to 400 Hz, line power.
-
product
General Purpose Basic Carrier Demodulator
CD15
The CD15 Sine Wave Carrier Demodulator operates with variable reluctance transducers to provide a DC output signal for dynamics as well as steady state measurements. A 5kHz sine wave excitation is applied to the two inductance ratio arms of the transducer and the resulting output is demodulated and amplified using the latest integrated circuit techniques. The DC output is obtained from an active filter circuit and gives a uniform response from steady state to 1000 Hz. The low impedance sine wave excitation allows operation with the transducer located over 1,000 feet from the CD15.
-
product
Variable Reluctance Absolute Pressure Sensor
AP10
The AP10, Absolute Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full-scale output of 40 mV per volt at 3kHz. The unit operates with carrier systems including the Validyne CD15 sine wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator to produce a high level analog DC output suitable for recording and control.
-
product
Portable Carrier Demodulator with Digital Display
CD379
The CD379 is a portable, completely self contained digital transducer indicator. In addition to the front panel liquid crystal digital display, the unit also provides a 2 Vdc analog output suitable for recording, remote display or control purposes. The unit is for use with all variable reluctance transducers and features solid state electronics, 3 1/2 digit liquid crystal display and battery pack with six 1.5V penlight cells for truly portable operation. The unit can also be powered from an external DC power supply or AC battery eliminator (converter) module.
-
product
Vehicle Data Acquisition System
VDAS
The Validyne VDAS integrates all your data acquisition requirements for vehicle testing into one compact, rugged system. Up to 300 vehicle sensor channels can be accepted by the VDAS so that time consuming change-outs of instrumentation packages can be minimized. The same VDAS is easily shared by several test groups; system configurations can be saved and re-loaded as needed.