product
Capacitance Bridge
1621
The GenRad1621 Capacitance Measurement system is a completely self-contained system capable of capacitance measurements in increments as small as 0.1 aF (10-4 pF) and conductance measurements in increments as small as 100 aU (10-7 U; equivalent to a shunt resistance of 1010 M). Measurements are three terminal, with 2- or 3-terminal connection, and provision is also made for the connection of an external standard for comparison measurements.
-
product
Micro-Ohmmeter
LOM-510A
The Micro-Ohmmeter has 4 digits, 0.02% basic accuracy and 1 resolution. The 4-terminal kelvin measurement connection minimizes lead resistance errors and 80 dB of ac noise rejection provides rock-steady readings even in noisy locations. The micro-ohmmeter comes with rugged 4-terminal test clips and a large selection of optional probes, clips and fixtures allowing attachment to any low-resistance unknown.
-
product
Precision Decade Capacitor
Genrad 1413
Six precision decades are employed to provide a range of 0 to 1.11111 F in increments of 1 pF and with an accuracy of 0.05% +0.5pF. Air capacitors are used for the two lower decades and highest grade mechanically stabilized sealed India Ruby mica capacitors are used for the remainder. Air trimmers are used for trimming the two lowest silvered-mica decades. The stability of the 1413 is such that it should not require readjustment with normal service. However, should it become desirable,the four lower decades contain trimmer capacitors that are accessible for this purpose.
-
product
Decade Capacitor
1419 Series
GenRad 1419-A and GenRad 1419-B (Polystyrene) Owing to its very low dielectric absorption, the GenRad 1419A 3 Decade 1000 pF/step & 1419B 4 Decade 100 pF/step Polystyrene Decade Capacitors are particularly useful in research and development work on computer and integrator circuits and on low-level amplifiers. Its constancy of capacitance and dissipation factor as a function of frequency also makes it extremely useful in measuring circuits and as a component in filters and tuned circuits. High insulation resistance and low dielectric absorption make it the 1419 Decade Capacitor a nearly ideal capacitor for dc work.
-
product
Resistance Substitution Box
RS Series
The RS Series Resistance Substitution Box is the most commonly used decade box on the market today. The RS Series is not only easier to use, but it is also priced lower than most its competition.
-
product
Standard Capacitors
1408 Series
Ultra-high stability. The continuously improvingaccuracy of capacitor calibrations by NISTbrings a better knowledge of capacitance tostandards laboratories - provided, of course,the laboratories have adequate referencestandards. The 1408 Reference Standard Capacitors,with their high stability, are suitablefor calibration in parts in 107. The 1616 PrecisionCapacitance Bridge is highly recommendedfor accurate calibration of a wide range ofworking standards from such a reference.
-
product
Decade Resistor
esi / Tegam DB62
IET has improved the specifications on esi/Tegam's DB62 decade resistor. These Decade Resistors are primarily intended for precision measurement applications where their excellent accuracy of 0.01%, stability, and low zero resistance are important
-
product
High Frequency Standard Capacitor
GenRad 1403 Series
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.
-
product
Benchtop LCR Meter
1692
The GenRad 1692 LCR Meter is a sophisticated, microprocessor-controlled tester that brings new levels of flexibility, simplicity and accuracy to RLC measurement. It's testing automation at its best with a range of programmable test frequencies and test voltages, as well as automatic limit comparison, automatic parameter selection, remote programmability, automatic binning and automatic zeroing. The display facilitates visual acquisition of test data and eliminates costly guesswork and errors. The 1692 LCR Meter provides a powerful combination of features designed to maximize productivity in production testing applications.
-
product
Cost Effective Capacitance Decade Box
CS Series
The CS Series Capacitance Decade Box is a cost effective and commonly used capacitance decade box for production and educational applications
-
product
Resistance & Capacitance Box
RCS Series
The RCS-box combines the features and specifications of both the R-box and the C-box in one convenient package. Ideal for setting timers, oscillators, and filters, the resistance and capacitance may be used independently, in series, or in parallel. A shorting link allows them to be coupled or separated.
-
product
Precision LCR Meter
1693
The GenRad 1693 LCR Meter Bridge gives you the best combination of features, in an LCR meter, to meet your most demanding testing requirements. It's a versatile, flexible instrument with a full range of programmable test frequencies, speeds, and voltages. An easy to understand display show both primary and secondary measurement parameters. The Digibridge is an excellent choice for metrology applications requiring accurate and repeatable measurements. The 1693 is also widely used in production testing, incoming inspection, component design and evaluation, process monitoring or dielectric measurement applications.
-
product
Decade Capacitor
GenRad 1423-A
The GenRad 1423 decade capacitor is a versatile tool for calibration laboratories and production-line testing. With it a bridge can be standardized to an accuracy exceeded only by that of the highest quality, individually certified laboratory standards such as the GR 1404 Reference Standard Capacitors.Used with a limit bridge, such as the GR 1689 Digibridge, the 1423 facilities fast and accurate production-line measurements of arbitrary capacitancevalues with minimum setup time.
-
product
Decade Capacitance Box
1412-BC
The wide capacitance range and high resolution of the GenRad 1412-BC decade capacitance box make it exceptionally useful in both laboratory and test shop. Owing to its fine adjustment of capacitance, it is a convenient variable capacitor to use with an Impedance Comparator. The polystyrene dielectric used in the decade steps is necessary for applications requiring low dielectric absorption and constancy of both capacitance and dissipation factor with frequency.
-
product
Precision Impedance Meter
1689
The GenRad 1689 Precision Impedance Meter gives you the best performance for your most demanding applications whether they be production test, incoming inspection, component design and evaluation, process monitoring or dielectric measurement. It is a versatile, full function microprocessor-based passive component tester that's available in a rack mountable, (1689M) model.