Gas Emission
See Also: Emission, Acoustic Emission, Radiated Emissions, Conducted Emission, Pollution
-
Product
Gas Analysis
QIC MultiStream
-
The Hiden QIC MultiStream is a complete, multi-stream gas composition monitoring system. Capable of analysing gas streams at flow rates from 4 ml/min up to 10 L/min. The system is suited to a range of applications where multi-component, multi-stream gas analysis is required, environmental monitoring for example.
-
Product
Personal Gas Detectors
-
Personal Gas Detectors keep workers safe from atmospheric hazards by continuously monitoring the user’s breathing zone, these detectors operate at close range to the user. Our range of personal gas detectors and monitors will allow you to operate in the toughest of industrial environments including hazardous areas and confined spaces.
-
Product
Transportable Gas Analyzer
CFP-8000
-
The CFP-8000 is pretreatment unit that is used with CGT-7100 or NOA-7100. When performing continuous gas analysis, dust and moisture must be removed from the gas before sending to the analyzer. This essential preprocessing can be performed by this one device, and two lines of cleaned measurement gas can be used simultaneously. Light-weight and compact, the CFP-8000 is the perfect preprocessor for use with portable analyzers.
-
Product
Industrial Gas Detector
OLCT 60
-
Teledyne Gas & Flame Detection
The OLCT 60AD version allows the sensor to be installed remotely up to 15 meters (standard), allowing detection in inaccessible locations, or in Zone 0 in the case of the intrinsically safe (IS) version. The detector units are made of 316L stainless steel, and are rugged and resistant to corrosion. Pre-calibrated sensors can be disconnected by turning the head of the unit. These “smart” sensors can be calibrated outside hazardous areas.The OLCT 60 is equipped with non-intrusive access to a safe menu. In hazardous areas, calibration can be done with an operating mode in accordance with safety rules.
-
Product
Rapidox 6100 Pump Back Gas Analyser
-
The Rapidox SF6 6100 Pump Back is a fully-automatic zero-emissions SF6 gas analyser, designed for controlling and monitoring the quality and purity of gas used in high voltage switchgear, circuit breakers and transformers.
-
Product
Gas Permeability Tester
EKT-2128BR
-
Windows Operation Software SystemWindows operation software system provides friendly operation environment also the following characteristics: 1. User can pre-set and save the testing specifications to save time of setting procedures before test. 2. User can choose and arrange the related coordinates such as retraction value corresponding to time and temperature. 3. After tests, all test curves and related test data can be saved and retrieved for future use.
-
Product
Temperature, Humidity, Pressure and Gas Sensor
BME680
-
The BME680 is a digital 4-in-1 sensor with gas, humidity, pressure and temperature measurement based on proven sensing principles. . This little sensor contains temperature, humidity, barometric pressure, and VOC gas sensing capabilities. All over SPI or I2C at a great price!
-
Product
Acoustic Emission Instrument
VPAC™II
-
The VPAC™II is an acoustic emission instrument based on over 10 years of research. The VPAC™II can estimate the quantity of material leaking through the valve using the accompanying proprietary software. With hundreds of systems currently in use, the VPAC™II valve leak detector is the instrument of choice for through valve leak detection.
-
Product
Acoustic Emission Calibrator
-
AE calibrator is similar to a simple signal generator, it can generate a variety of controlled waveform signal, different types, different amplitude and different frequency. It can help users calibrate acoustic emission detection equipment before acoustic emission detection.
-
Product
Fast Response Gas Detector
Leaksurveyor
-
Teledyne Gas & Flame Detection
The GMI Leaksurveyor combines quality, ruggedness and advanced Technology in a user friendly, portable gas detector. The integral fast response and high sensitivity semiconductor sensor enables leakage surveys to be performed and distribution leaks to be quickly found.
-
Product
Flue Gas Analyzer (Instrument Only)
C160
-
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C160 Residential Combustion Analyzer is instrument only, easy to use with a rugged design, multiple sensor protections and altitude compensation. Essential information for installing and maintaining furnaces and boilers all in one device.
-
Product
Distillation Gas Chromatograph System
-
The Shimadzu simulated distillation system, consisting of a Nexis GC-2030 high-performance capillary gas chromatograph and LabSolutions simulated distillation GC analysis software, meets all applicable ASTM, ISO, EN, and JIS standards. Permitting accurate and highly reproducible analysis of high-boiling components in crude oil samples, it is the optimal system for product quality control and process management in oil refinery plants.
-
Product
Air And Gas Probe
GT-1
-
GT-1 Air and Gas Probe - 24'' #304 stainless steel shaft. Wooden Handle. For instant readings of temperature gradients in environmental chambers, freezer boxes, etc. Diameter is .3/16'' diameter. Immersible. Maximum temperature 200°C, Time constant Seconds. 5 foot lead. Not isolated.
-
Product
Stack Gas Analysis System
ENDA-5000 series
-
Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2 and O2.HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's new ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross-flow modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a new intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.
-
Product
Gas Filter Correlation Carbon Monoxide Analyzer
Model T300
-
The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Gas Chromatograph-Mass Spectrometry
-
Designed to maximize laboratory productivity and minimize environmental impact
-
Product
Atmospheric Pressure Gas Analyzers
-
The Cirrus™ single-quadrupole mass spectrometers are powerful analytical tools for a wide range of laboratory and industry-based gas analysis applications. The Cirrus family, featuring the Cirrus™ 3 and Cirrus™ 3-XD atmospheric pressure gas monitoring systems are ideal for analysis of bulk gas, gas composition, and detection of trace gasses and contamination. These powerful, versatile and customizable platforms, when combined with Process Eye™ Professional software and its recipe-based control, can significantly boost your productivity.
-
Product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model N360M
-
Teledyne Advanced Pollution Instrumentation
The Model N360M measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360M uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
Product
Gas Chromatography
-
Scientific Instrument Services, Inc.
Gas chromatography (GC) is an analytical technique used to separate and detect the chemical components of a sample mixture to determine their presence or absence and/or quantities.
-
Product
Gas Accumulation Indicator
Qualitrol 038
-
Mechanical measurement of gas accumulation within a conservator style transformer. Alarm functions warn when level hits maximum limit and remains on until sufficient gas is removed. Sampling port allows your personnel to draw-off of gas for laboratory analysis.
-
Product
Gas Analysis
HPR-20 EGA
-
The Hiden HPR-20 EGA gas analysis system is configured for continuous analysis of evolved gases and vapours from thermogravimetric analysers, TGA.
-
Product
Dual Display Digital Pressure Sensor [For Gas]
DP-100
-
Panasonic Industrial Devices Sales Company of America
The DP-100 Dual Display Digital Pressure Sensor is a highly accurate and reliable Pressure Sensor that is equipped with a new visual display that features a wider viewing angle and improved clarity. The pressure and set range part of the display has also been increased as another improvement. The DP-100 Series also offers a multi-function type that enables the selection of analog output (voltage/current) or external input (auto-reference/remote zero-adjustment) to comply with a wide range of applications.
-
Product
Motor Exhaust Gas Analyzer
MEXA-ONE
-
MEXA-ONE offers an intuitive user interface with a highly efficient hardware and software design.This results in increased testing efficiency and economical facility operation, while enhancing reliability and accuracy. These advancements are possible because the MEXA-ONE software employs new "HORIBA ONE PLATFORM". This platform integrates the test devices in an emission cell into a single user interface, increasing efficiency and optimizing user control over the entire testing process.
-
Product
Fixed Gas Detectors
700 Series
-
Teledyne Gas & Flame Detection
The sensor electronics are completely protected and immune to water ingress and corrosion. The sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small handheld magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. The 700 Series intelligent sensor modules feature dual redundant outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output.
-
Product
Mobile Gas Leak Detection System
ABB Ability
-
ABB Ability mobile gas leak detection system uses ABB’s patented Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) technique which has a sensitivity and precision more than 3000 times greater than legacy methods. This enables identification of leaks several hundred feet away from the source. Current traditional leak detection technology is slow, laborious and costly. Operators walk on foot near the pipeline with hand-held sensors making paper-based reports.This is slow and can lead to dangerous leaks being missed or not identified in a timely manner. ABB’s Ability mobile gas leak detection system delivers a low cost per leak solution with low false positives. Reporting includes mapping of the leaks available via a mobile app and measurements as Cloud-based service. The system consists of ABB’s Methane/Ethane Analyzer, a GPS, a sonic anemometer and proprietary leak detection software that presents real-time geospatial maps of multiple gas concentrations in real time. The software’s sophisticated leak detection algorithm combines the system’s measurements of gas concentrations (CH4, C2H6), local coordinates (GPS) and local wind velocity (sonic anemometer) to estimate the location of the leak. Readings are stored in the device and can be transmitted in real-time to the cloud for centralized monitoring.
-
Product
Gas Filter Correlation CO Analyzer
Model N300
-
Teledyne Advanced Pollution Instrumentation
The Model N300 is a microprocessor-controlled analyzer based on the Beer-Lambert law that is used to determine the concentration of carbon monoxide (CO) in a sample gas.The N300 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb Infrared (IR) light. The analyzer passes the IR light beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure.
-
Product
Thermal Conductivity Gas Analyzer
CI2000-RQD
-
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
Determining gas concentrations by measuring the thermal conductivity of the gas, CI2000-RQD analyzer uses advanced thermal conductivity sensor with single chip technology. It adopts platinum thread as sense organ to make up Imbalance Bridge, which output signal has a relationship with tested gas volume. And the single chip will magnify, sieve wavelength, modify linearly and criteria the signal by electric procedure.
-
Product
Tracer Gas Diffuser Kit
DIF-KIT
-
The Kanomax tracer gas diffuser kit is used in performing tracer gas tests in accordance with ANSI / ASHRAE Standard 110. The diffuser is designed to the specifications of standard drawing #110-83M.
-
Product
Gas Monitoring System
TRIGARD
-
Designed to meet a variety of demanding applications, from wastewater facilities, to light industry and commercial applications, the TRIGARD Gas Monitoring System features MSA's precision craftsmanship and detects chlorine, sulfur dioxide and other toxic and combustible gases.





























