Product
RLC Load Banks
-
Guangdong EMAX Electrical Co., Ltd.
Elevate your power testing capabilities with our RLC Load Banks. Engineered for precision and accuracy, these load banks deliver exceptional performance and control, ensuring the longevity of your power systems. Experience unmatched quality and reliability.
-
Product
Time Domain Replication (Road Load Simulation)
-
The powerful graphical editor makes it easy to review and compile your field sample data for use in the test lab. The point editor, filters, velocity and displacement compensation ensure the test feasibility is evaluated at an early stage. The continuous closed-loop controller then replicates the test files with very high levels of precision. The control algorithms use a continuous coherence averaging technique to ensure a stable proactive control loop that will not only provide accurate replication but will also respond to changes in test item dynamics.
-
Product
PET Bottle Vertical Load Tester
VP-1000
-
VP-1000 PET Bottle Vertical Load Tester is professionally designed to test the top load resistance, container body side load resistance of the PET container.
-
Product
RC-50 Artificial Phantom Load with Power Factor
480
-
The RC-50 Artificial Phantom Load with Power Factor (Catalog No. 480) has been re-designed to meet the most exacting requirements. It operates from a single phase source and will deliver current at either unity or 50% power factor at all full load ranges.
-
Product
500 AMP Carbon Pile Load Tester
710
-
The #710 will perform variable load testing on 12 volt batteries rated as high as 1000 Cold Cranking Amps. Use this battery tester to simulate actual cranking loads. Also tests alternator charging voltage and relative starter current draw. The #710 features large dual meters to display the battery voltage and load current simultaneously, during the test.
-
Product
AC Load Bank (Rack Mounted)
K-1000 Rack Mounted
-
Kongter Test & Measurement Co., Limited
Rack mounted resistive load bank is widely used in data center to simulate electric loads and dissipation of IT systems. These load banks are controlled by sectional steps with customized setting. Users could set power and time as per their needs with easy operation.
-
Product
110V / 100 Amp Load
BD12-110P-48/24
-
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with 110V battery systems and is extremely costeffective.
-
Product
Low Capacity Single Point Bending Beam Load Cells
LSP SERIES
-
The LSP Series is a low capacity, low cost, high accurate single point bending beam load cell. It is ideal for OEM applications such as electronic scales and weighing machines. The single point design is highly resistant to eccentric loading allowing direct mounting to the scale base and weighing platform. The LSP Series features a moisture proof sealant.
-
Product
Load Pins, Tension Load Links, And Load Shackles
-
Interface’s wide range of load pins are designed for the measurement of tensile and compressive forces across a wide variety of applications, including crane/lifting, industrial, marine, offshore, and civil engineering. Machined from high tensile stainless steel, our load pins are suitable for use in exposed situations including prolonged immersion in seawater. Interface’s tension load links are designed for lifting and weighing applications in harsh environments and manufactured from high tensile aluminum and stainless steel. Interface’s load shackles are manufactured from high tensile carbon steel and the basic shackle uses the renowned Crosby G2130, G2140, and G2150 series (depending on the load rating).
-
Product
DC Electronic Load
-
Siglent SDL1000X series Programmable DC Electronic Load features an input range up to 150V/30A/300W. CC Dynamic mode frequency is up to 25 kHz. It delivers stability over a wide range of applications and can meet all kinds of testing requirements including: Power, battery/handheld device design, industry, LED lighting, automotive electronics, and aerospace.
-
Product
Oscilloscope, 100 MHz, 2 GS/s interleaved, 4 CH, 200 Mpts/Ch DSO, Fully Loaded with 10.1" Color Display
T3DSO2104HD
Oscilloscope
The T3DSO2000HD series of Bench Oscilloscopes feature 4-channel models with analog bandwidth options of 100 MHz, 200MHz and 350 MHz. The T3DSO2000HD Oscilloscopes use 12-bit high resolution ADCs and a low noise front end which provides an impressive noise performance to cover a wide range of measurement applications. Each model offers a maximum sample rate of 2 GSa/s (interleaved) and a maximum memory depth of 200 Mpts in interleave mode. The MS configured models also include a 16 channel logic probe as standard.
-
Product
Multi-channel DC Electronic Load
IT8700 Series
-
IT8700 series programmable DC electronic load adopts removable modules design, supports up to 16 channels with mainframe extension transient mode up to 25 kHz, which improves your test efficiency, with high resolution and accuracy. Users can freely choose in the 8 load modules according to the number of channels and power requirements, controlled by mainframe control panel, or controlled by host computer software via built-in LAN / RS232 /USB / GPIB interface.
-
Product
Battery Load Bank
-
Foresight Electronics Co., Ltd.
Utility is used for battery systems range from 21-30V, if higher current is needed, two or more FST-24V units can be linked together. Discharge to Battery string voltage as 24V, Cell voltage as 1.2V/2V/6V/12V adjustable stop points and multiple alarm designs to control the discharge process intelligently 7inch LCD touch screen for easy operation and showing various parameters real time Support RS232 real time monitoring by PC or SD Card download data after discharge
-
Product
Signal, Module, Receiver, QuadraPaddle, iCon Series, 160 Position, loaded w/ Twin Female Contacts and Round Posts
510160122
Receiver Module
Fully Loaded with Twin Female Contacts and Round Posts (Adapter Pins) (p/n's 610138200 and 610138117).Primary mating module 510161101. (May mate with other ITA modules, as well.)
-
Product
Thermocouple, Insert, ITA, SIM, 8 Pos, 3 Slot (not loaded)
510181111
SIM Insert
Thermocouple, Insert, ITA, SIM, 8 Pos, 3 Slot (not loaded)Compatible with 410130116, ITA, i2 MX, 22 Slot VTAC/SIM Insert, EMI, and XL version 410130133Not loaded. Thermocouple patchcords need to be purchased separately.
-
Product
Rod End Load Cells
-
Our rod-end load cells are designed for integration into tension measurement. They are versatile, durable, and fit easily into small spaces such as inline with vehicle tie rods.
-
Product
Oscilloscope, 100 MHz, 2 GS/s interleaved, 4 CH, 200 Mpts/Ch interleaved, Fully Loaded DSO with 16 Dig Ch MSO
T3DSO2104HD-MS
Oscilloscope
The T3DSO2000HD series of Bench Oscilloscopes feature 4-channel models with analog bandwidth options of 100 MHz, 200MHz and 350 MHz. The T3DSO2000HD Oscilloscopes use 12-bit high resolution ADCs and a low noise front end which provides an impressive noise performance to cover a wide range of measurement applications. Each model offers a maximum sample rate of 2 GSa/s (interleaved) and a maximum memory depth of 200 Mpts in interleave mode. The MS configured models also include a 16 channel logic probe as standard.
-
Product
Load Cell Power Supply
MODEL PSMR
-
The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.
-
Product
SIM, Module, Receiver, 90 Series, Fully Loaded with pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106)
510170102
Receiver Module
This fully loaded SIM module kit comes with 34 pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106). This kit also includes two PCB brackets for securing module to PCB.
-
Product
Portable Load Cell System
-
Load Cell is designed by Seismic Source Company to measure the Hold Down weight and the output force of the Servo Hydraulic Vibrator unit. The output of the Load Cells can be recorded with any accurate seismic recording system.
-
Product
Regenerative DC Electronic Load
IT8000 Series
-
IT8000 series is a family of high power regenerative electronic loads with compact size. The highly integrated capability enables the e-load to simulate various e-load characteristics, and return the consumed energy back to the grid cleanly, saving costs related to energy consumption and cooling, meanwhile eco-friendly. With modular high power density design, IT8000 provide up to 18kW in 3U space.
-
Product
LED Load Simulator
63110A/ 63113A/63115A
Simulator
As shown on the V-I curve in figure 1, the LED has a forward voltage VF and a operating resistance (Rd). When using a resistor as loading, the V-I curve of the resistor is not able to simulate the V-I curve of the LED as shown in blue on figure 1. This may cause the LED driver to not start up due to the difference in V-I characteristic between the resistors and the LEDs. When using Electronic Loads, the CR and CV mode settings are set for when the LED is under stable operation and therefore, is unable to simulate turn on or PWM brightness control characteristics. This may cause the LED driver to function improperly or trigger it’s protection circuits. These testing requirements can be achieved when using a LEDs as a load; however, issues regarding the LED aging as well as different LED drivers may require different types of LEDs or a number of LEDs. This makes it inconvenient for mass production testing.
-
Product
Load Cell Measurement
-
Designed specifically as a single-board solution for material testing system (MTS) applications, the PCI-9524 combines a high 24-bit resolution with 1/200,000 count accuracy to provide the most precise load cell measurement PCI board available in the market today.
-
Product
Digital Roller Brake Tester for Cars and Vans up wot 3.5 T Axle Load with 2 x 3 kW Drive Motors and Max. Track Width of 2,200 mm
C_MBT C 3.5 W220 | VP 210152
-
Maschinenbau Haldenwang GmbH & Co. KG.
Digital roller brake tester for cars and vans up to 3.5 t axle load with 2 x 3 kW drive motors and a max. track width of 2,200 mm.Particularly suitable as stand-alone tester or as part of car reception and diagnostic test lanes.
-
Product
1800 Watt DC Electronic Load Mainframe
N3300A
Mainframe
The Keysight N3300A is a full-rack width mainframe with 6-slots that accepts combinations of N330x user-installable load modules (150 W to 600 W) for easy system configuration and future reconfiguration. The N3300A holds up to six N3302A, N3303A, N3304A, N3307A load modules, or three N3305A, N3306A double-wide modules, allowing a total up to 1,800 watts of maximum power.
-
Product
Load Banks
-
The only way to be certain that your stationary batteries will perform to specification is to test the batteries’ capacity with a DC load bank / portable battery discharge tester.
-
Product
Dummy Test Wafers/Chips
-
Advanced Dummy Test Wafers/Chips available with over 35 different chip designs and choices of 11 different material configurations as well as kits complete with test vehicles. Custom-make test production of TEG wafer/glass (TEG=Test Element Group). Design and provide custom-make test kit.
-
Product
Channel Load Generator
802.11p
-
Qosmotec Software Solutions GmbH
When many cars are equipped with 802.11p communication technology, high traffic density will also cause significant load on the radio channel. From normal wireless communication systems it is a known problem, that many users can cause a complete breakdown of the network. Car-to-X communication technology tries to protect itself against those kind of breakdown by a carrier sensing mechanism: Each communication device has to check first, if the radio channel is busy. In that case, it waits for a random delay to avoid packet collision on the radio channel, which causes a loss of both collided packets.