PXI Multiplexers
-
Product
PXI Single 4 to 1 RF Multiplexer 2GHz 50 Ohm SMB Terminated
40-740-511
-
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
Product
PCI Very High Density Multiplexer, 24-Channel, 4-Pole
50-670C-021-24/4
-
The 50-670C-021-24/4 is a 24-channel, 4-pole MUX and is part of a series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.The 50-670C shares exactly the same architecture as the established 40-670 range of PXI modules.
-
Product
PXI 2 Banks of 80 Channel 1 Pole MUX
40-615-022-2/80/1
-
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration. Connections are made via a front panel 200-pin connector.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 26.5 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-785C-531-TE
-
The 40-785C-531-TE (PXI) and 42-785C-531-TE (PXIe) are single failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP4T, 26.5GHz, 50Ω, SMA, Terminated, Remote Mount
40-785C-433-TE
-
The 40-785C-433-TE (PXI) and 42-785C-433-TE (PXIe) are triple SP4T 26.5GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI High Voltage Power Multiplexer, Dual 12:1
40-331A-002
-
The 40-331A-002 dual 12:1 MUX is part of our range of 40-331A/332 High Voltage Power Multiplexer and Matrix Modules and is suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching.
-
Product
LXI Microwave Multiplexer, SP6T, 8-Bank, 18GHz, 50Ω, SMA
60-800-108
-
Our 60-800-108 is a 8 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
LXI Microwave Multiplexer, SP6T, 4-Bank, 50GHz, 50Ω, SMA-2.4
60-800-604
-
Our 60-800-604 is a 4 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI 2 Amp Multiplexer, Dual 4-Channel, 4-Pole
40-635A-107
-
The 40-635A-107 is a dual 4-channel, 4-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI 8-slot BRIC Multiplexer, 96-Channel, 10-Pole (8 Sub-cards)
40-570A-416
-
The 40-570A-416 is a 96-channel, 10-pole High-Density Multiplexer and is part of our BRIC family. The 40-570A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
Product
PXI/PXIe High Density 2A Multiplexer, 10-Bank, 4-Channel, 3-Pole
42-614D-022
-
The 40-614D-022 (PXI) and 42-614D-022 (PXIe) 10-bank, 4-channel, 3-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above).
-
Product
PXI/PXIe High Density 2A Multiplexer, 1-Bank, 16-Channel, 8-Pole
42-614D-018
-
The 40-614D-018 (PXI) and 42-614D-018 (PXIe) 1-bank, 16-channel, 8-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber
40-852A-018-M62.5-HI
-
The 40/42-852A-018-M62.5-HI is a PXI/PXIe 8-channel multiplexer with FC/APC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP12T, 18 GHz, 50 Ω, SMA, Remote Mount, Failsafe
40-788-222-E
-
The 40-788-222-E (PXI) and 42-788-222-E (PXIe) are dual failsafe SP12T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI Solid State MUX, 1 bank, 160 channel
40-680-006
-
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 50/125 Fiber
40-850A-514-M50-HI
-
The 40/42-850A-514-M50-HI is a PXI/PXIe 4-channel multiplexer with ST connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI/PXIe High Voltage Multiplexer, Dual 4-Channel, 2-Pole
42-321-120-HI
-
The 40-321-120-HI (PXI) and 42-321-120-HI (PXIe) are dual 4-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 18 GHz, 50 Ω, SMA, Failsafe
42-785C-422
-
The 40-785C-422 (PXI) and 42-785C-422 (PXIe) are dual failsafe SP4T 18 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 12-Bank 18GHz SMA
60-801-212
-
The 60-801-212 is a 6-channel, 12-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe Very High Density Multiplexer, 99-Channel, 2-Pole
42-675B-002-99/2
-
The 40-675B-002-99/2 (PXI) and the 42-675B-002-99/2 (PXIe) are 99-channel, 2-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems.
-
Product
LXI Microwave Multiplexer, SP6T, 12-Bank, 50GHz, 50Ω, SMA-2.4
60-800-612
-
Our 60-800-612 is a 12 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber, FC/APC Connectors
42-852A-018-M50
-
The 40/42-852A-018-M50 is a PXI/PXIe 8-channel multiplexer with FC/APC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber, FC/APC Connectors, With Interlock
42-852A-018-HI
-
The 40/42-852A-018-M50-HI is a PXI/PXIe 8-channel multiplexer with FC/APC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 67 GHz, 50 Ω, SMA-1.85, Terminated, Failsafe
40-785C-472-T
-
The 40-785C-472-T (PXI) and 42-785C-472-T (PXIe) are dual failsafe SP4T 67 GHz with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe USB Data Comms Multiplexer, 16-Channel
42-737A-001
-
The 40-737A-001 (PXI) and 42-737A-001 (PXIe) are 16:1 USB data communications multiplexers suitable for switching USB1 and USB2 data and power connections using a 78 way D-Type connector. The data signal paths are 2-pole arranged as differential pairs as defined by the USB standard.
-
Product
PXI/PXIe High Voltage Multiplexer, Single 9-Channel, 2-Pole
42-321-124-HI
-
The 40-321-124-HI (PXI) and 42-321-124-HI (PXIe) are single 9-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
Dual 16 to 1 Terminated 50Ω 600MHz PXI RF Multiplexer
40-765A-002
-
The 40-765A-002 terminated dual 16 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
PXI/PXIe MEMS Optical Switch, Quad Insert/Bypass
40-860A-342
-
The 40/42-860A-342 is a PXI/PXIe quad insert/bypass switch with MU connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
LXI High Voltage Switching - 3-Bank, 1-Pole, 12:1 Multiplexer Plugin Module
65-231-905
-
The 65-231-905 plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 9 kV.
-
Product
High Performance LXI RF & Microwave Multiplexers
-
Our standard microwave multiplexers offer the highest density configurations available, packaging up to 16 SPnT switches into a 2U high rack-mount enclosure. Standard microwave multiplexer systems include 50Ω Versions up to 67 GHz and 75ΩVersions up to 2.5 GHz. Alternatively, you can use our Microwave Switch Design Tool to mount any combination of our wide range of transfer and SPnT relays onto your own front panel design.