PXI Multiplexers
-
Product
LXI Microwave Multiplexer, SP6T, 11-Bank, 18GHz, 50Ω, SMA
60-800-111
Microwave Multiplexer
Our 60-800-111 is a 11 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Single 8 to 1 Terminated 50 600MHz PXI RF Multiplexer
40-763-001
Multiplexer Module
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
LXI Microwave Multiplexer, SP6T, 16-Bank, 67GHz, 50Ω, SMA-1.85
60-800-816
Multiplexer Module
Our 60-800-816 is a 16 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 67GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXIe Microwave Multiplexer, Single SP6T, 26.5 GHz, 50 Ω, SMA, Failsafe
42-785C-531
Microwave Multiplexer
The 40-785C-531 (PXI) and 42-785C-531 (PXIe) are single failsafe SP6T 26.5 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe High Density 2A Multiplexer, 8-Bank, 16-Channel, 1-Pole
42-614D-003
Multiplexer Module
The 40-614D-003 (PXI) and 42-614D-003 (PXIe) 8-bank, 16-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe High Density 2A Multiplexer, 2-Bank, 32-Channel, 2-Pole
42-614D-011
Multiplexer Module
The 40-614D-011 (PXI) and 42-614D-011 (PXIe) 2-bank, 32-channel, 2-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
1x4 Multiplexer Plug-In
1260-134
Multiplexer Module
The Astronics1260-134 is a sixteen 1x4 multiplexer plug-in card for the Adapt-a-Switch® platform. It installs, easily and directly from the front panel, into the Adapt-a-Switch VXI Carrier, 1260-100.
-
Product
PXI High Density MUX BRIC, 2-Chan, 160-Pole
40-570-012
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
PXI/PXIe RF Multiplexer, Single 4-Channel, Terminated Common, 3GHz, 50Ω, SMB
40-876A-001
Multiplexer Module
The 40-876A-001 (PXI) and 42-876A-001 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
PCI Very High Density Multiplexer, 99-Channel, 2-Pole
50-670C-022-99/2
Multiplexer Module
The 50-670C-022-99/2 is a 99-channel, 2-pole MUX and is part of a series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
LXI Microwave Multiplexer, SP4T, 8-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-803-508
Multiplexer Module
Our 60-803-508 is a 8 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI Single 4 to 1 RF Multiplexer 2GHz 50 Ohm SMB Terminated
40-740-511
Multiplexer Module
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
Product
PXI Hex 4:1 High Voltage Power MUX
40-331-004
Multiplexer Module
The Pickering Interfaces 40-331/332 High Voltage Power Multiplexer and Matrix Modules are suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VDC peak cold switching and 110VDC/250VAC hot switching. The 40-331 is available as a single 24:1, dual 12:1, quad 6:1, hex 4:1, octal 3:1 or twelve 2:1 multiplexer, and the 40-332 is available in 12x2 or 6x4 matrix configurations. Connections are made via a front panel mounted 37 pin high voltage D-Type connector.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber, FC/PC Connectors
42-852A-118-M62.5
Multiplexer Module
The 40/42-852A-118-M62.5 is a PXI/PXIe 8-channel multiplexer with FC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
Product
PXI/PXIe RF Multiplexer, Single 4-Channel, Terminated Common, 3GHz, 50Ω, MCX
40-876A-101
Multiplexer Module
The 40-876A-101 (PXI) and 42-876A-101 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
PXI 2 Amp Multiplexer, 2-Bank, 32-Channel, 1-Pole
40-657A-001-2/32/1
Multiplexer Module
The 40-657A-001-2/32/1 is a 2-bank, 32-channel, 1-pole MUX and is part of our range of High Density 2 Amp Power Multiplexer Modules available in a choice of configurations, containing up to 8 separate multiplexers, all 1-pole switching. They are suitable for switching signals to 110VDC/250VAC at 2Amps, 90W.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 18 GHz, 50 Ω, SMA, Failsafe
42-788-021
Multiplexer Module
The 40-788-021 (PXI) and 42-788-021 (PXIe) are single failsafe SP8T 18 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T configurations with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 67 GHz, 50 Ω, SMA-1.85, Terminated, Remote Mount, Failsafe
42-785C-572-TE
Multiplexer Module
The 40-785C-572-TE (PXI) and 42-785C-572-TE (PXIe) are dual failsafe SP6T 67 GHz with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI Dual 4 to 1 RF Multiplexer 3GHz 50 Ohm MCX Terminated
40-876-102
Multiplexer Module
The 40-876-102 is a 50 Ohm 4 to 1 RF multiplexer with 2 banks in a single PXI slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40-876 has been minimized by careful attention to the mechanical and electrical design.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Single-Mode, 9/125 Fiber, FC/APC Connectors, With Interlock
42-850A-014-HI
Multiplexer Module
The 40/42-850A-014-HI is a PXI/PXIe 4-channel multiplexer with FC/APC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 3 GHz, 50 Ω, N-Type, Remote Mount, Failsafe
42-785C-562-E
Multiplexer Module
The 40-785C-562-E (PXI) and 42-785C-562-E (PXIe) are dual failsafe SP6T 3 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
Combination SPDT/Multiplexer Module
1260-37
Multiplexer Module
The Astronics 1260-37 contains 40 Form C (SPDT) switches and eight 1x6 multiplexers. The multiplexers can be expanded using the on-board jumpers to four 1x12, two 1x24 or one 1x48 two-wire channel.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 18GHz, 50Ω, SMA, Remote Mount
40-784B-122-E
Multiplexer Module
The 40-784B-122-E (PXI) and 42-784B-122-E (PXIe) are dual SP4T 18GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 50 GHz, 50 Ω, SMA-2.4, Failsafe
42-785C-451
Multiplexer Module
The 40-785C-451 (PXI) and 42-785C-451 (PXIe) are single failsafe SP4T 50 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 6 GHz, 50 Ω, SMA, Failsafe
42-784B-002
Multiplexer Module
The 40-784B-002 (PXI) and 42-784B-002 (PXIe) are dual failsafe SP6T 6 GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode
40-850A-014-M62.5-HI
Multiplexer Module
The 40/42-850A-014-M62.5-HI is a PXI/PXIe 4-channel multiplexer with FC/APC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
LXI Microwave Multiplexer, 50Ω 36-Channel 1-Bank 4GHz BNC
60-891-001-002
Multiplexer Module
The multiplexer has an extremely high level of performance with low VSWR, very high isolation, low loss and high power handling. It is ideal for switching 50Ω systems for HF up to microwave frequencies. It occupies 2U of rack space, providing a compact switching solution.
-
Product
LXI Microwave Multiplexer, SP6T, 8-Bank, 50GHz, 50Ω, SMA-2.4
60-800-608
Microwave Multiplexer
Our 60-800-608 is a 8 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
Keysight 70-Channel Reed Multiplexer for 34980A
34924A
Multiplexer Module
The Keysight 34924A module for the 34980A Multifunction Switch/Measure Unit is a high-density, high-speed multiplexer for general purpose scanning. It uses reed relays to achieve scan rates up to 500 channels-per-second. Use this module for high-throughput automated test applications as well as high-speed data logging and monitoring tasks.
-
Product
PXI MUX 4 Bank 0f 16 Channel 1 Pole
40-610-021-4/16/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer





























