Partial Discharge
voltage discharge within an insulator causing dielectric breakdown.
See Also: Partial Discharge Detection, Partial Discharge Monitors, PD, PD Test, Partial Discharge Test
-
Product
Portable Partial Discharge/ Detection
AE-150
-
The AE-150 is designed to detect and localize Partial Discharge activity inside oil-insulated power transformers. This instrument is a powerful diagnostic tool that combines electric and acoustic sensing technologies to perform partial discharge pinpointing.
-
Product
Partial-discharge Detection System
GDYT Series
-
GDYT series include partial discharge power frequency testing transformer(YDTW),partial discharge detector(GDJF2008),Isolation filter frequency doubling power device(GDSF-81G) and power frequency withstand voltage control table(GDYD table).It widely used in electrical manufacturing,power operation departments, research institutes and universities.
-
Product
Partial Discharge Pulse Calibrator
TPK
-
Partial discharge puls calibrator TPK is a battery-powered handheld device for determining the correction factor in a Partial Discharge test circuit and to verify the Partial Discharge measurement.
-
Product
Handheld PD Tester
-
Weshine Electric Manufacturing Co., Ltd
TEV partial discharge inspection instrument uses two emerging technologies, transient-to-ground voltage (TEV) measurement and ultrasonic (US) measurement, to detect faults in switchgear. The equipment is portable and easy to operate. The TEV sensor is attached to the wall of the box, and the US sensor scans and detects along the gap on the switch cabinet.
-
Product
AC Insulation Testing
-
Weshine Electric Manufacturing Co., Ltd
High-voltage Dividers (High Potential Divider) are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they are used to measure alternating voltage (AC), direct voltage (DC), lightning impulse voltage (LI), and switching impulse voltage (SI) systems. High-voltage dividers by HIGHVOLT comply with the relevant IEC standards. The systems are available for both indoor and outdoor use.
-
Product
Sensor Technology
-
Power Monitoring and Diagnostic Technology Ltd.
PMDT is the only manufacturer to utilize all 5 types of online partial discharge sensor technology. Using multiple sensing methods ensures that PD activity is always discovered, located, and characterized. PMDT's handheld PDetector and PDStar units have more capability than the high-end diagnostic equipment of the past. The small handheld, battery powered unit can completely perform the test and analysis without the need of a PC. PDetector, PDStar, and PDiagnostic instruments feature high-resolution phase-resolved analysis of PD signals (PRPD and PRPS) in real time, so you get your test results instantly!
-
Product
Substation Series Testers
GTPD-92
-
Partial discharge(PD) is a pulsed discharge that produces a series of physical phenomena and chemical changes such as light, sound, electrical and mechanical vibrations in and around electrical equipment.
-
Product
Online Partial Discharge Alarm System
PD Annunciator™
-
The PD Annunciator™ unique design consists of a three channels acquisition module paired with sensors of your choice, most commonly TEV and Acoustic or HFCT. With many advancements and innovations, the PD Annunciator™ handles partial discharge monitoring on metallic cabinets using our proven and advanced technologies.
-
Product
Qualification and Quality Control Tests
Techsquare
-
New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.
-
Product
Horn Antenna
-
Horn antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in electric assets like GIS and GIL or MV and HV power transformers. It is a broadband antenna with a flat response which makes Horn antenna suitable in a number of different applications. It has been optimized to operate in a frequency range suitable for PD activity monitoring and it was designed to provide maximum sensitivity and high gain.
-
Product
Transformer Testing And Monitoring
-
Can detect the symptoms of transformer failure by monitoring the cooling system, load tap changer, dissolved gas, bushing power factor and capacitance, partial discharge, oil levels, pressure, temperatures and more.
-
Product
TEV Antenna
-
TEV sensor is a partial discharge sensor whose working principle is based on a direct Capacitive coupling with a Switchgears earthed metal case. The two ends of TEV sensor can be coupled magnetically to virtually any opening on a metal Surface. It picks up the electric signal given by PD activity onto the two metallic surfaces. Thanks to its special design has high sensitivity, larger than other single ended TEV sensors. His compact and robust design (passive sensor) makes the TEV the optimal sensor for direct installation on medium voltage Switchgears.
-
Product
Compact Ultrasonic Testing Device
SONAPHONE® Pocket
-
With the SONAPHONE Pocket you identify problems even before they arise and create value at all levels of your company. Just by detecting and eliminating leaks you can reduce the energy costs for your compressed air system up to 30 percent. This also has positive effects on your operational safety and system productivity through early warning of bearing failure and evidence of partial electrical discharges.
-
Product
Multi-Channel PD System Locator
PDiagnostic Series
-
Power Monitoring and Diagnostic Technology Ltd.
The PDiagnostic is a portable system that utilizes Ultra-High Frequency (UHF), Acoustic Emissions (AE), High-Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV) sensors to detect, analyze, and locate the PD signals in real time for a multitude of medium and high voltage electric power equipment.The multi-channel PDiagnostic system locates PD on power equipment down to a meter by utilizing Acoustic-Electromagnetic Combination Location Technique, Time Difference of Signals’ Arrival (TDOA), Partial Discharge Signals Separation (PDSS), and 3D Positioning Technology with PC software included.The system features advanced PD diagnostic capabilities, automatic PD type pattern recognition, and accurate PD location capabilities. The PDiagnostic is an ideal trouble-shooting tool for your PD programs. Severity is determined and maintenance suggestions are provided accordingly.
-
Product
Partial Discharge Testing Equipment
PD-Analyser
-
This is an ‘All in One’ solution for testing and analysing partial discharges in the insulation of high-voltage transformers, cables, GIS and electric machines. The DIMRUS ‘PD Analyser’ help diagnose their insulation state and find any type of defects very effectively.It can be used for temporary or constant monitoring of partial discharge in medium and high voltage systems and cables of any rated voltage.The PD Analyser is the most useful device for condition estimation of high-voltage insulation. This multipurpose device is designed for -Partial discharge measuring in high-voltage insulation at a high noise level.Fast detecting of the defects in different high-voltage equipment and identifying how dangerous they are.
-
Product
Dielectric Loss Tangent Testing Instruments
-
Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.
-
Product
Cable Diagnostic Tools
-
For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.
-
Product
Partial Discharge Detector
APD-ANNUNCIATOR
-
The APD-ANNUNCIATOR is a remote partial discharge detection equipment inside any energized cabinet. The probe is installed in the unit under test, instantly reporting its status. This equipment gives a great benefit because it avoids long term damage to the switching equipment.
-
Product
Flexible Magnetic Coupler
FMC
-
The FMC (Flexible Magnetic Coupler) is a partial discharge sensor whose working principle is based on a direct magnetic coupling with the cable conductor and shield.It picks up a magnetic signal given by PD activity. His compact and robust design makes the FMC the optimal sensor for direct installation on cables and accessories such as joints and termination.This sensor has a sensitive side which has to face to the object under test, while the other side (shielded) reject the noise from the environment.
-
Product
Insulation Resistance Meter
AMIC-15k1
-
The partial discharge indicator PDI. Diagnosis of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD. Allows to test the electrical durability of the tested object - indication of breaking voltage. The high resistance to electromagnetic interference ensures uninterrupted operation in power plants and near high-voltage transmission lines up to 1200 kV AC and 500 kV DC.
-
Product
PD Measuring System
TEM
-
Partial discharge test system for laboratory or on-site measurement according to VDE 0434, IEC 60270 and EN50178 consisting of:*Partial discharge meter TMG*High-voltage coupling capacitors for decoupling of the PD pulses*Partial discharge calibrator TPK for determining the correction factor in the PD test circuit
-
Product
Partial Discharge Testing
-
Weshine Electric Manufacturing Co., Ltd
Using the Windows system operating platform, you can freely choose ellipse, straight line, sine wave display, two-dimensional, three-dimensional graphic analysis mode, spectrum window, Q-V-F three-dimensional characteristic window, and static detailed measurement, observation and analysis of partial discharge pulse of one-cycle test voltage .
-
Product
Shielded Rooms
-
HIGHVOLT Prüftechnik Dresden GmbH
Electromagetic field and line-conducted interference needs to be eliminated in order to measure low-intensity partial discharges with a PD background noise level (≤ 1 pC) in accordance with IEC 60270.
-
Product
Electrical Safety Multi-Analyzer
TOS9300 Series
-
The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
Product
Partial Discharge Tester
GTPD-2C
-
GTPD-2C Digital partial discharge tester is the digital partial discharge measuring and analyzer adopting the complete new generation technology. It is suitable for partial discharge detection in manufacturing factory and field handover test of transformers, generators, CT/PT, bushings, GIS, capacitors, power cables, switches and other high-voltage electrical equipment with various voltage levels and capacities.
-
Product
HV Coupling Capacitors
-
Our high-voltage coupling capacitors are a main component of our partial discharge test stations. They serve to decouple the partial discharge impulses and act as a voltage divider, the output voltage of which is matched to our partial discharge measuring devices (with integrated voltage measurement) and peak voltage measuring devices. These high-voltage components are also available separately in their various designs, sizes, capacities and voltage ranges.
-
Product
Spiral Antenna UHF Trafo
-
UHF Spiral antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset. It is a broadband antenna with a flat response which makes Spiral antenna suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes Spiral antenna the optimal sensor for direct installation on high voltage Transformers. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces. Contact our sales department for consulting.
-
Product
Partial Discharge Calibrator
TPK-H
-
The high voltage-resistant Partial Discharge calibrator is used to determine the correction factor in the PD test circui.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).