Ground Fault
-
Product
Ground Fault Detectors
-
STB Electrical Test Equipment, Inc
STB's convenient Ground Fault Detectors may be operated with one hand and are ideal for preventative maintenance. Ground Fault Detectors indicate ground faults and electrical leakage while equipment is in operation.
-
Product
5mA High Accuracy Ground Fault Detector
HA-GFD
-
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
Product
Socket Tester
1945
-
Peaceful Thriving Enterprise Co Ltd
This is a portable 220VAC socket tester to inspect the wiring conditions. The tester also features current variation for simulation of different leaking current. With the current variation, technician is able to test the condition of Ground Fault Circuit Interrupter (GFCI) / Residual Current Device (RCD) easily.
-
Product
High Impedance Differential Module
HID
-
Use the HID module in conjunction with a high-speed overcurrent relay to provide three phase high impedance differential protection for substation busbars of any voltage level. Additionally, it can also be used to protect electrical machines like transformers, generators or motors against restricted ground faults.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Service Drop Locator
VM-560
-
The VM-560 is a general-purpose locator used to detect buried pipe and cable services in a variety of situations. With a 50/60Hz passive power locating frequency and three active frequencies, the VM-560 locator will meet the requirements of those wishing to detect the presence of active power cables and to trace short ranges. The VM-560 transmitter also has the additional frequency of 8kHz Fault-find so it can be used to detect the presence of ground to sheath faults on cable when used with the VM-510 Stand Alone A-Frame fault locator.
-
Product
Fault Locator
VM-510FFL+
-
Finding the location of an underground cable fault just became easier with the VM-510FFL+ Standalone A-frame locator. Now locating a suspect cable and finding the fault can be done with the VM-510FFL+ and a compatible transmitter. There is no longer a need for a separate utility locator with cables connecting to it. After connecting a compatible transmitter to the line and placing it in a Fault-Find mode, use the simple to operate four button controls of the VM-510FFL+ to locate and stay on the cable path while pinpointing the sheath or ground fault.
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
Fault Insertion Unit
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel
40-200-008
CAN Interface
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
Field Ground Module
SEL-2664
-
Schweitzer Engineering Laboratories, Inc.
Add the SEL-2664 Field Ground Module to the SEL-300G or SEL-700G to protect all the critical components in your generator with one comprehensive relay. Or, add the SEL-2664 to the SEL-2664S to complete ground fault protection on both the rotor and stator.
-
Product
Voltage-Pen-Detector
-
Are a relatively simple testing instrument that enables electricians and other uses tolocate, trace and identify common electrical problems. These testers can locate wires behind walls, underground,and inside junction boxes. Others are designed to find blown fuses or test light fixtures. Some testers can evenlocate neutrals, ground faults, and high voltage lines without interrupting power
-
Product
Electric Shock Protection Analysis
-
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
Product
Ground-Fault Location Products for Ungrounded Systems
-
When combined with Bender's ground-fault detectors and current transformers, EDS series modules provide fast, automatic ground-fault location in ungrounded systems. Fault location takes place while the system remains online without the need to open branch circuit breakers or disconnect equipment. Bender's fault location system works on both AC and DC systems, as well as systems with variable frequency drives. A standalone, portable fault location system is also available.
-
Product
Ground Fault Finder
FST-JD200 DC
-
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...
-
Product
Air Core Neutral Grounding Reactors
-
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
-
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.
-
Product
Portable Testing
-
Whether you need handheld testers, digital hydrometers, ground fault detectors or discharge testing equipment, we offer the cutting-edge technology you need to stay ahead in managing and maintaining your power systems.
-
Product
Ground Fault Monitor
IFT-120
-
Our ground fault monitors enable you to easily and quickly find the source of the fault before a major problem occurs and damages your equipment. This is the IFT-120, designed to assist you in rapid identification of ground faults.
-
Product
DC Earth Fault Locator
GFL-T + GFL-R
-
The DC Earth Fault locator is suitable to test the DC Battery System and Trace Ground Faults. The system is suitable for Power Plants, Sub-Stations upto 765KV and other industries. The system is highly capable in tracing and pin pointing the DC earth faults in a live system without requiring any shut downs. The receiver sensitivity of 1mA and better is capable to trace most complex fault.
-
Product
Variable Power Supply
VS3
-
The VS-3 power supply is a very convenient portable, non-isolated “variable source” from 0 volts to 150 Vac or 0 volts to 150 Vdc and rated for up to 3 amps, thus the name VS-3. It is comprised of an illuminated voltmeter that reads to the first significant digit, AC variable system output voltage, DC variable system output voltage, logic output voltage and one sense (continuity) contact monitoring points. Banana jacks for connection of test leads are spaced at intervals that allow the use of dual banana test plugs if desired. The VS-3 is protected by two levels of overcurrent protection; AC input, and ground fault protection by a GFCI. All circuitry is housed inside a custom designed case made from 16 gauge steel. An Internal fan dissipates heat buildup and exhaust through louvered side vents built into the case. The carrying handle is designed with a “spring return to rest” position and is padded for comfort. The case has been sized for optimum portability and is balanced from the handle during transportation. The case has a powder coated finish that is scratch, chemical and weather resistant. Rubber padded feet support the case when in the upright position and a convenience receptacle is located on the side of the case. A unique feature of the VS-3 is that it contains “Magnet Packs” on the back of the case. These “Magnet Packs” can support the VS-3 and allow it to “hang” from any magnetic metal surface. The VS-3 can be powered by our UPS system, eliminating the need for an extension cord. The ability to magnetically attach the VS-3 near the source of connection and eliminating the need for an extension cord makes the VS-3 a “must have tool” for technicians.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
40-204-001
Multiplexer Module
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
Product
Mobile Cable Fault Location System
BAUR Syscompact 4000
-
Fault location with Syscompact 4000. The Syscompact 4000 is a compact, fully enclosed fault location system for pre-location and pinpointing of high-resistive, low-resistive and intermittent faults on low- and medium-voltage cables. Easy operation and the use of latest fault location methods enable fast and safe fault location.* Location of low-resistive, high-resistive and intermittent cable faults* Efficient cable fault pre-location methods* Pinpointing according to the noise location method or acoustic propagation time measurement* (with Universal Locator and ground microphone)* Sheath fault location according to the step voltage method (with Universal Locator and two measurement probes)* Easy to handle
-
Product
Bus Bar Protection
BUS1000/2000
-
The BUS 1000/2000 is a solid state, high speed protectionsystem for the detection of phase-to-phase andphase-to-ground faults on bus bar installations. It can beused to protect high voltage bus bar installations of anyvoltage.
-
Product
Earth Fault Detector
K-3838
-
Kongter Test & Measurement Co., Limited
Kongter’s K-3838 earth fault detector is the updated model which is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems where electrical cables have breakage and current lost to ground. It will save you from long time unnecessary troubleshooting and helps to increase the reliability of your electrical equipments. Our unique technique makes it safe and fast to handle earth fault in DC systems that are working online.
-
Product
Relays, Switches, Sensors
-
CR Magnetics Sensing Relays and Switches provide a simple method of monitoring electrical properties and alerting a system to a fault or event condition. These products are available with a wide variety of configurations, including time delays, various output styles and logic. From simple proving switches, to fully featured high performance ground fault sensing.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Battery Ground Detector
BGD
-
Battery Ground Detectors supply contact closures for alarm indications at precise ground fault resistance settings.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-402
Fault Insertion Unit
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.