Automatic Calibration Module
ACM2506
-
ACM2506 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 6.5 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Automatic Calibration Module
ACM2509
-
ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process.
-
Product
Crossover Calibrator
CC-1
-
The purpose of this tool is to enable the installer to set the crossover frequency of an electronic crossover to the desired frequency, accurately and quickly. It can also be useful for matching gains on multiple amplifier competition type systems.
-
Product
Mask ventilation resistance and pressure differential tester
WKS-3102
-
Mask ventilation resistance and pressure differential tester is used to measure the inhalation and exhalation resistance of mask under specified conditions. Applicable to mask manufacturers, labor protection equipment inspection agencies to carry out related testing and inspection of mask products, mask breath resistance tester, breathing valve air tightness tester, breath resistance machine for measuring respirator and mask protection products in Inspiratory resistance and expiratory resistance under specified conditions.
-
Product
Conformance Calibration Standard Test Card for GS1-DataBar Symbol Verifiers
AI-CCS-DATABAR
-
This test card is ideal for testing verifiers, scanners, and other GS1-DataBar barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
Product
Electronic Resistance Store
MEMS5
-
Mezzanine MEMS5 is designed to reproduce the values of resistance to direct current through five channels independent and galvanically isolated from each other and from the case.
-
Product
3 Wire (Analogue) Earth Resistance Tester
ST-1505
-
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● The timer operates automatically for about three to five minutes when the “PUSH BUTTON SWITCH” and “TIMER ON BUTTON” are pressed together. ● This will keep test “ON” for the duration of the timer.● Battery check function.● Calibration performed with supplied test leads.
-
Product
Ground Resistance Clamp Meter
61-920
-
*Auto ranging*Auto power off*Hard case included*2-year warranty
-
Product
Open-Short-Load RF calibration kits
-
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
Product
Bench Power Supply, Calibrated, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL
-
The 72-2690 CAL from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
Product
10KV High Voltage Digital Insulation Resistance Tester
KM 6213AIN
-
Kusam Electrical Industries Limited
• The KM 6213A IN is the KUSAM-MECO premium model of High Voltage Digital Insulation Resistance Testers.• The KM 6213A IN has new added features with a low consumption High Performance processor.• It displays results much faster and has more advanced features.• The KM 6213A IN has Automatic Polarization Index and Dielectric Absorption Ratio Calculations.• Results are displayed on the new High Contrast LCD. It’s mounting angle makes it more readable for all users, in different working conditions.• The user’s manual reflects the new features and added benefits of this instrument.• It has Auto-Off, Auto-Stop, EnerSave™ and is a non destructive tester.• Once you start the tester, it waits for your selection. You can go up and down in voltage to select the voltage at which you want to test the insulation. Once you have selected that voltage, you need to connect the test leads to the Insulation Tester to measure. Then it measures voltage to ensure there is no voltage present on the equipment under test. If there is a voltage present, it will warn you to disconnect the circuit before proceeding. If it’s free of any voltage, then you can proceed with the testing. This ensures that no damage is done to the Insulation Tester KM 6213AIN.• One of the new innovation on this tester is also the way the new unique calibration process works. It’s fully digital, has no moving parts and does not require expensive and complicated jigs or computers systems to be calibrated. It’s cheaper to maintain than any other Digital HV Insulation tester on the market today. The KM 6213AIN is supplied standard with our Premium test Leads Kit, the AL-50.
-
Product
Calibration Devices For Spring Impact Hammer
CX-TF06A
-
Shenzhen Chuangxin Instruments Co., Ltd.
Calibration Devices for Spring Impact Hammer
-
Product
Electronic Store Of Resistances
PS8
-
The module is intended for use as part of information measuring systems based on the VXI bus for software setting of resistance values with a given step along three independent channels.
-
Product
Sphygmomanometer Calibrator
-
Huaxin Instrument (Beijing) Co., Ltd
Here at Huaxin, as an expert test equipment solution provider, we are proud to offer a selection of pressure calibrators for precise calibration of sphygmomanometer in laboratory and on site. Our sphygmomanometer calibrators find wide applications in metrology bodies, hospitals, university labs, etc.
-
Product
Zero Gas Generator - Calibration of Ambient Air Monitoring Systems
ZNV-7
-
HORIBA Europe’s Zero Gas Generator ZNV-7 has been developed to check the zero point and dilute the span gas sources in order to carry out the calibration of ambient air monitoring systems. The increasing sensitivity of ambient air analyzers is required by strict official guidelines, which demands pure and dry air in a sufficient quantity at constant pressure.
-
Product
Large Calibre Barrel Bore Gauge System
BG20
-
Aeronautical & General Instruments Ltd.
The BG20 has been specifically designed to modernise and improve the inspection routines of large calibre barrels. A two-point measuring head is supported in the barrel or chamber by a clear disk which facilitates the angular alignment of the head and the location of a suspected defect.
-
Product
Calibration Kit
N612
-
*N612 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
Product
Metal Alloy Low Resistance Chip Resistor
MR
-
*Low Resistance / TCR / Inductance*Excellent long term stability*RoHS compliant and halogen free*Lead free*High precision current sensing and voltage division
-
Product
Electrical Calibrators
-
An electrical calibrator, or dc calibrator from Fluke Calibration includes many innovative and multi-functional solutions to help laboratories operate efficiently, increase throughput, and comply with today’s quality standards. Versatile models and options provide a wide range of possibilities to match a variety of workloads and budgets. Electrical calibrators include: Multi-product calibrators; multifunction calibrators; oscilloscope calibrators; power calibrators; pressure/temperature calibrators.
-
Product
Fully Automatic Non-contact Sheet Resistance Measurement System For Flatpanel Display
NC-60F/RS-1300N
-
*Global standard for non-contact measurement of ITO film, Metal thin films on flat panel*Automatic X-Y and Z (eddy current probe head) axis moving mechanism*Compatible with Loading robot for fully automatic measurementOption :*Integlate to combined system (film thickness meter, etc)*Add 4 point probe measurement unit : RT-3000
-
Product
PLTS Measurement And Calibration
N19303B
-
The new Physical Layer Test System (PLTS) 2024 is the industry standard for signal integrity measurements and data post‑processing high-speed interconnects, such as cables, backplanes, PCBs, and connectors. Signal integrity laboratories worldwide have benefited from the power of PLTS in the R&D prototype test phase.
-
Product
Partial Discharge Measurement Calibrator
DAC-CP-2
-
DAC-CP-2 is a calibrator for partial discharge measurements. The electric charge enables to generate up to max 10000pC. It is battery-operated and can be charged by connecting to the measuring instrument (DAC-PD-3).
-
Product
Electronic Calibration Module, DC To 6.5 GHz, 2-Port
N7551A
-
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
Calibration
-
Calibration of a measuring tool is an operation that allows an assessment of the accuracy of the measurement, and the adjustment of the measuring tool so that it is more accurate. In scientific formulation, calibration makes it possible to evaluate the measurement error.
-
Product
Broadband Calibrated Noise Sources
-
Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.
-
Product
Microphone Calibration Workstation
9350C
-
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
Product
Single channel Memory Earth Resistivity and IP Meter
SuperSting R1 IP
-
The SuperSting R1 IP is a state-of-the-art single-channel portable memory earth resistivity meter with memory storage of readings and user defined measure cycles. It provides the highest accuracy and lowest noise levels in the industry.This new instrument is based on technology developed for the famous SuperSting R8/IP multi-channel instrument.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
-
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Calibrator, Calibrated w/D & U, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL DU
-
The 72-6694 CAL DU from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.