Filter Results By:
Products
Applications
Manufacturers
-
product
Oil Tan Delta Tester
Weshine Electric Manufacturing Co., Ltd
The Oil Tan Delta Tester (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. WESHINE has developed features of the OTD to ensure that productivity levels within laboratories are maximised.
-
product
Surface Quality Measurement System
SQM-500W
SQM-500 Surface quality Measurement system is used for the surface cleanness testing and analyze of sample. SQM provide a quantitative analysis of the cleanness of the surface, which was the first announced by us. The system can be used to non-contract detect the contamination of the surface and provide an accurate result immediately. The result can provide a powerful and real data for analyze, which is the insurance for the quality.
-
product
Sindie Online
Sindie Online is an industrial-grade process analyzer delivering continuous sulfur detection to monitor fuel streams and help to prevent tank contamination. It has many advantages over competing technologies: Powered by MWDXRF, Sindie Online has an exceptional signal-to-noise ratio using monochromatic excitation of the X-ray source characteristic line – a technique that is faster, safer and cleaner than UVF.
-
product
Health Physics Systems
Detection and quantification of radioactive material within the body is a key factor in determining internal personnel contamination and dose assessment. These measurements can be made on body fluid samples using lab instrumentation or through direct measurement of personnel. The measurement of body fluids is generally less attractive due to the bio-hazards and lack of immediate results unless non-gamma emitting nuclide measurements are required. The direct measurement of personnel for gamma emitting radioactive material provides rapid results, can determine where the material may be located within the body, and does not require mobility of the material through body fluids for detection.
-
product
PicoClean MTP/MPO One-Click Cleaner
MTC-12
Shanghai Fibretool Technology Co.,Ltd.
Many troubles in optical communications equipment are caused by contamination on the optical connector end face.The MPO/MTP connector cleaner, employs microfibers designed specifically for optical connectors to remove even the smallest contamination not visible to the naked eye.
-
product
Smoke Detector Tester
Solo 365
The fire industry’s most popular range of detector test equipment is about to get even better. Solo, the test equipment used world-wide to functionally test fire detectors has a new tester in its range – Solo 365. This exciting innovation provides fire safety professionals with an array of stand-out features which make for faster, simpler and cleaner functional testing of smoke detectors. Key features include automatic generation of smoke which ensures only the amount of smoke needed to activate the detector is produced – minimizing smoke wastage and eliminating the risk of detector contamination. In addition, Solo 365 is light in weight and has a slim-line design which allows easy access into tight spaces – making it possible to test detectors which are hard to access with other portable testers. In response to market feedback, Solo 365 features an LED torch which automatically illuminates when light levels drop, making for easy detector alignment and testing in dark environments. Smoke is generated via newly designed smoke cartridges which fit neatly into the rear of the tester. With no reliance on pressurised aerosol cans, the cartridges can be easily shipped and stored and are unaffected by new regulations, set for 2018, which will affect availability of some pressurised smoke aerosols.
-
product
Digital Dailysate Meter
Digital Dialysate Meter™ D4 & D6
The DIGITAL DIALYSATE METER is specifically designed to test both acetate and bicarbonate dialysate quality. Measure Conductivity, pH and Temperature to ensure proper mixing during dialysate preparation and as a final check of dialysate quality before hemodialysis treatment. There are no strips or reagents that expire or subjective interpretation of results. Internal sensors require the user to place the sample in the instrument, preventing contamination of dialysate by the measurement device.
-
product
Surface Contamination Monitor
IMI Inspector Alert™ V2
The IMI Inspector Alert™ V2 measures alpha, beta, gamma and x-radiation using a 2-inch “pancake” GM detector with high sensitivity to common beta and alpha sources. The easy-to-read digital display shows readings in your choice of µSv/hr, mR/hr, CPM, or CPS. The Total/Timer feature allows timed readings from one minute to 40 hours for precise measurement of low level contamination. An audible alert sounds when the radiation reaches a user-adjustable level.
-
product
Abrasive & Blast Inspection
Blasting parameters: A number of important parameters need to be monitored during the blasting or water jetting process, these include: air pressure (at the nozzle), nozzle diameter, blast media contamination & pH values in order to avoid recontamination of the substrate during blasting.
-
product
Optical 12,000 Meter Connector
Teledyne Impulse-PDM’s 5135/5175 optical connectors utilize proven standard ferrule technology and are available for multi-mode or single-mode operation.The connectors are manufactured in Titanium Ti 6Al-4V, which is electro-polished to remove surface contamination, thus improving resistance to corrosion. The engaging nuts are also manufactured in the same grade of Titanium and the threads are coated with a Nickel/PTFE composite coating to prevent galling. The connectors have been qualifi ed to 12,000 meter operating depth.
-
product
Root Cause Failure Analysis
Maintenance Reliability Group, LLC
Root Cause Analysis of Grease Lubricated Components: Root cause analysis includes a complete root-cause failure report and recommendations for further monitoring and corrective actions. MRG will test for grease consistency, oxidation, product contamination and wear metals utilizing Grease Thief® Analyzer die extrusion test, FTIR, RULER and RDE Spectroscopy. Testing includes Analytical Ferrography and Rheometer testing. Testing can include the submission of a failed component for extraction of grease from failed component and visual inspection for Root Cause Analysis.Root Cause Analysis of Grease Lubricated Components: Root cause analysis includes a complete root-cause failure report and recommendations for further monitoring and corrective actions. MRG will test for grease consistency, oxidation, product contamination and wear metals utilizing Grease Thief® Analyzer die extrusion test, FTIR, RULER and RDE Spectroscopy. Testing includes Analytical Ferrography and Rheometer testing. Testing can include the submission of a failed component for extraction of grease from failed component and visual inspection for Root Cause Analysis.
-
product
Metal Detector
Safeline Profile Advantage
For challenging inspection applications where a product is wet, hot, chilled or cooling Profile Advantage technology provides the ultimate in metal contaminant detection capability. All metal contamination including ferrous, non-ferrous and even the most difficult to detect non-magnetic stainless steels are readily detected enabling them to be removed effectively from the manufacturing process.
-
product
AOI Handlings System
The AOI handling system is a compact facility with various test units. Via an ionization cleaning station the ceramics are transferred to the contacting station. There, the resistance values of the substrates are tested with a rigid needle adapter. Afterward, the ceramics are further conveyed to the three (optionally four) AOI test stations (for automatic optical inspection) and are tested for cracks, unevenness, faulty imprints, contamination, etc. The poorly evaluated ceramics arrive at a review station where the operator can assess and evaluate the errors on the monitor. If the operator is uncertain about a fault, the ceramic in question can be positioned under the microscope position and inspected by eye. Poorly defined ceramics are marked accordingly with an ink pen.
-
product
Dial Indicators
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
product
Surface Quality Monitors
PET manufactures and markets non-destructive, non-contact surface contamination and thin film detection models and automated systems (surface quality monitoring system) capable of detecting thin layer contamination, thin films and coating down to the Angstrom level. These systems represent a major breakthrough by providing, for the first time, a quantitative measure of surface cleanliness. As surface cleanliness verification instruments, in a part cleaning environment, these products are capable of validating the cleaning quality of all the part cleaning equipment available in the market. Any of SQM model series is capable of verifying metal contamination; monitoring absence/presence of organic and/or inorganic on virtually on surfaces of all metals. They are, price/performance, the most sufficient product available for testing surface of metals for surface cleanliness. These systems operate in an ambient environment, require no sample preparation or deposit of any agents on the surface. In any parts cleaning environment where the quality and efficiency of part cleaning equipment for removal of surface contamination is highly desired, these systems provide a scientific solution by quantitatively measuring the surface cleanliness. The SQM series has the sensitivity and operational simplicity required to provide fast and cost effective surface evaluation for all metals.
-
product
Safety Proximity Sensors
Leuze electronic GmbH + Co. KG
With their encapsulated and contactless design, safety proximity sensors are insensitive to contamination and humidity. They operate free from wear and also have a long life expectancy, even with frequent operating cycles. They are also used wherever it is difficult to precisely guide the moveable protective device. All devices feature a high-strength plastic housing. Furthermore, the devices with RFID transponder provide maximum protection against tampering.
-
product
Pollution Monitoring/ Water Quality Sensing
PickMol
Detect organic contamination in water faster, cheaper and on the spot. Patented and validated solution that brings a new quality of pollution monitoring / fresh water sensing.
-
product
Fluid Contamination Test
Fluid contamination testing determines the abilities of materials to withstand the contaminating fluids, to which they are exposed in service.
-
product
Silver Ball Matrix Sockets
SM Contact is a unique contact that has precise silver balls held together by a proprietary conductive formulation. These conductive columns (diameter optimized for 50 ohm impedance) are suspended in a non-conductive flexible elastomer substrate with a patented solid core for enhanced durability and reliable performance over time, temperature and cycles. This flexible substrate is very compliant and resilient and enables the conductive columns to revert back to original shape when the force is removed. Solutions are available for 0.25mm to 1.27mm LGA, BGA, QFN, CSP, POP, WLP and other packages. The silver ball matrix contact technology is also available with a protective plunger matrix (a gold plated copper cylinder) that sits on top of the conductive columns. This plunger matrix protects the conductive column from contamination from various solder ball interfaces. A quickly replaceable plunger matrix enables minimal downtime during final production test. The product family code for this line of sockets is SMP.
-
product
Air Samplers
Coriolis Air samplers are dedicated to the collect of biological particles in the air which bring new perspectives for the control of airborne contamination thanks to its liquid sample.
-
product
Integrated Displacement Sensing
IDS3010
With its slim size, the IDS can be directly integrated into machines for free-beam operation and is the product of choice for challenging OEM & synchrotron applications. A passively cooled housing prevents contamination of optical and electrical components.
-
product
Analytical Techniques
Anderson Materials Evaluation, Inc.
Our numerous analytical techniques, we tackle a wide range of materials challenges and commonly combines several analytical techniques to fully address complex and multi-dimensional materials issues. Our materials analysis laboratory provides XPS surface analysis, thermal analysis (TGA, DSC, TMA), FTIR infrared spectroscopy, UV-Vis spectrophotometry and reflectivity measurements, gas chromatography – mass spectroscopy (GC-MS), SEM/EDX, optical microscopy, mechanical testing, electrochemistry and corrosion analyses, residual gas mass spectroscopy, contact angle measurements, surface contamination measurements, adhesive bonding failure analysis, facility testing for silicone contamination, mechanical testing, metallography and fractography, density and porosity measurements, volatile organic component testing, friction, and other analytical capabilities. We continue to upgrade and expand our arsenal of analytical techniques and custom analytical methods to support our customers’ needs.
-
product
Airborne Particle Counters
Complete contamination control solution including cleanroom certification and clean area monitoring, while meeting global requirements for data integrity.
-
product
SOLUBLE SALT TESTER
The PosiTector SST Soluble Salt Tester measures the concentration of soluble salts (salt contamination) on metal surfaces in accordance with ISO 8502-6, 8502-9. View Video
-
product
PXI Dual 8 Channel Switch Simulator
40-485-121
Designed to simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. It allows automotive I/O devices to be tested for correct operation under adverse conditions.
-
product
Pulse AC Method Area Ionizers
ER-X Series
Panasonic Industrial Devices Sales Company of America
The ER-X Series Area Ionizers utilize the pulse AC ionization design to achieve high-speed charge removal of wide surface areas for high-volume production lines. In addition to supporting compressed air ionization, the ER-X also features both airless and low-pressure ionization modes for applications where tiny workpieces can be easily blown away. Additional features include automatic ion balance and discharge frequency control (manual control is also possible), flat discharge surface for easy cleaning, discharge needle air barrier design to reduce contamination of the needles, replaceable discharge needle unit for easy maintenance, and a dual head configuration for enhanced charge area and layout (2 different ionizer heads can be connected to a single controller).
-
product
Portable Particle Monitor
iCountOS
The iCountOS is a highly rugged portable particle size monitor that can be used for measuring contamination levels in fuels and/or hydraulic fluids. Capable of operation online (direct connection to system) or offline (sampling from tank or reservoir).
-
product
Straightness and Squareness Carrying Case
10787A
The Keysight 10787A carrying case is included with the Keysight 55283A Straightness Measurement Kit and protects the optical equipment from shock, vibration, moisture, impact, and contamination. It also serves as a secure enclosure for storage, shipping, or for transport between operating locations.
-
product
Hot Blocks for Acid Digestion
QBlock Series
QBlock series provides wide selection to choose appropriate hot block to increase efficiency of digestion and through put. Teflon coated graphite block and enclosure provides ability to produce contamination free results. Modular approach for Commander, touch screen base temperature controller helps increase life span of system and provides total control over 4 QBlock simultaneously.
-
product
Contamination Detection and Analysis
Contamination testing, detection, analysis, troubleshooting and resolution expertise to minimise downtime, maintain customer confidence, for quality & safety