product
DC Load Banks
Guangdong EMAX Electrical Co., Ltd.
DC load banks for all voltage levels and power test applications, available in a variety of models including portable and fixed models.
-
product
LOADpro Load Testers
LoadPro is an external Web load testing service. A LoadPro test simulates actual user traffic from outside your network, stressing your entire infrastructure in order to discover bottlenecks that impact performance under peak traffic.
-
product
PowerSync Programmable Load
Lower cost solutions for versatile 802.3at and 802.3bt Powered Device Emulation to support PSE system test and analysis
-
product
Cells and Electrodes
Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.
-
product
Electronic Loads
T3EL Series
The T3EL series is a family of single channel, 200 & 300 Watt Electronic Loads that are ideal for R&D, product validation and Q&A in a bench or automated environment for low to medium power applications starting from 60mA, such as electronic components, batteries, portable chargers and power products. Electronic Loads are typically used to provide a load to the outputs of a power supply, usually capable of dynamic loading, and are fully programmable. Electronic Loads help designers to test electronic power products and ensure quality, reliability, and performance.
-
product
Top Loading Industrial Ovens
Gruenberg manufactures two, specialty industrial top loading ovens that are designed for multiple processes, including annealing, preheating and baking. Their rugged durability are well suited for oil and gas applications. Standard and custom options accommodate a variety of processing applications including drying, curing, baking, aging and more.
-
product
Single Use Cells
S.U.C.
optek Single Use Cells have an integrated conductivity sensor and enable simultaneous electrochemical and optical measurements. Various options of line sizes and connections allow for a simple integration into bioprocessing systems from low volume research up to high volume biopharmaceutical manufacturing.
-
product
AeroEngine Test Cells
A tec is a leading provider of jet engine test cells and flight component support. We provide our customers with high quality, superior value maintenance facilities and equipment for the testing of all types of turbine engines. We excel in both the design and construction of new facilities and the technological refreshment and sustainment of legacy systems. The Atec companies operate worldwide with new test cells, test cell modifications, engine test adapters, ADAQ™ control systems, support equipment, test benches, utilities subsystems, site surveys, repairs and training, and Master Service Agreements (MSAs).
-
product
DC Electronic Load
EE30180A
The EE30180A DC Electronic Load / Works @ 0.0 Volts Input & real time I/O control. attach the electronic load block to a heat- sink and your up and running.
-
product
HDDH-3932 Single Cell Battery Activator
HD Power Test Equipment Co.ltd
HDDH-3932 Cell Activator is used to discharge and charge and activate for disable single cell battery, which is simple, safe and accurate test device.The instrument is with perfect protection function, sound and light alarm and clear interface tips.
-
product
Wafer and Cells PL System
HS-PL
Photoluminescence (PL) Imaging is a unique non-invasive inspection tool as it can be used in-line at many different steps of the cell manufacturing process. This facilitates the direct comparison of data obtained at one process step to data obtained at another. Additionally, PL imaging can be compared to electroluminescence (EL) imaging on finished cells using comparable equipment.
-
product
Flow Cell Kit
QCMT
The quartz crystal microbalance (QCM) technique under electrochemical frequency is very useful to determine many compounds such as metal proteins, metal ions and thiol-conjugated oligonucleotides.
-
product
Power Meters and Calibration Cells
The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.
-
product
Unclamped Inductive Load Tester
ITC75100
The ITC75100 is an enhanced unclamped inductive load (UIL) test system that builds on the success of ITC’s industry leading ITC55 series of testers by adding additional test and measurement capability.
-
product
Digital Battery Load Tester
DBT125
Battery load test. Depending on the size of the battery, this product adds a very high load to the battery (125 A). It enables the reading of battery condition by voltages and by its ability to maintain the load, thus determining levels of sulphation.
-
product
Load Support Unit
LSU220A
The LSU220A is a general purpose load support unit designed to act as a permanent power supply to maintain backup battery systems whilst alternative sources of power are either impractical or unavailable, such as running diesel engines during maintenance programs.
-
product
RLC Load Banks
Guangdong EMAX Electrical Co., Ltd.
Elevate your power testing capabilities with our RLC Load Banks. Engineered for precision and accuracy, these load banks deliver exceptional performance and control, ensuring the longevity of your power systems. Experience unmatched quality and reliability.
-
product
Programmable DC Electronic Loads
SDL1000X/X-E Series
SDL1000X/SDL1000X-E series Programmable DC Electronic Load has a 3.5 inch TFT-LCD display, a user-friendly interface and superb performance specifications. The SDL1020X/SDL1020X-E models feature an input range of 150 V/30 A 200 W while the SDL1030X/SDL1030X-E have an input range of 150 V/30 A 300 W. The SDL1000X series leads with measurement resolution of 0.1 mV/0.1 mA and the base SDL1000X-E series resolution is 1 mV/1 mA and adjustable current rise times from 0.001 A/μs~2.5 A/μs. For remote communication and control, the SDL series includes RS232/USB/LAN interface types. The SDL1000X series delivers stability over a wide range of applications and can meet all kinds of testing requirements. including: Power, battery/handheld device design, industry, LED lighting, automotive electronics, and aerospace.
-
product
Calibrated Solar Reference Cell
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
product
LOADED BOARD TEST PROBES
SERIES-70
ElectricalMAXIMUM CURRENT: 5 amps continuousat working travel, non-inductiveRESISTANCE: At 35mA test current70 18 mOhms mean73 60 mOhms mean74 40 mOhms meanMaterials and FinishesPLUNGER: Heat treated beryllium copperor steel hardened to 55-60RC70 24Kt gold plated over nickel73 24Kt gold plated over nickel74 Rhodium plated over nickelBARREL: Nickel silver70 24Kt gold plated ID and OD over nickel73 No Finish74 24Kt gold plated ID and OD over nickel
-
product
Combined Load Banks
C-Series
C-series combined load banks are devices which contain resistive and reactive loads, apply the load to an electrical power source and dissipate the power of the electrical power.
-
product
BIB Loading
FALCON Series
The Falcon Series is an automated BIB loading and unloading machine. It is designed to provide precise high-speed loading of DUTs from Trays/Tube to Burn-in boards and precise high-speed unloading of DUTs from Burn-in boards to Trays/Tube for different device packages. The Falcon Series also has a simple conversion kit which allows end-users to re-configure the equipment for different types of sockets and package combinations.
-
product
Auto Loading Durometer
P2 Auto Durometers maximize the repeatability of hardness tests. The P2 features digital speed control to ensure constant speed during hardness tests. The proprietary flexible coupling ensures perfect contact with test samples. All operation and program functions are controlled using the touch screen LCD panel or remotely using an Ethernet connection. Both automated or manual tests can be performed. Dual timers enable recording of the “creep phenomenon” or tendency of the reading to move back as time elapses from the moment the sensor makes full contact with the sample.
-
product
Single Cell Hardware
A Fuel Cell Hardware Assembly consists of a pair of Poco Graphite Blocks with a precision, machined flow-pattern (pattern is serpentine unless otherwise specified by the customer), and a pair of gold plated connectors fastened with aluminum end plates. Gas inputs and outputs are through Swagelok fittings. A thermocouple well and two cartridge heaters are also provided. A single Anode Reference Electrode may be added for an additional cost. The FCT Cell Hardware does not include a Membrane Electrode Assembly (MEA).
-
product
Regenerative DC Electronic Load
IT8000 Series
IT8000 series is a family of high power regenerative electronic loads with compact size. The highly integrated capability enables the e-load to simulate various e-load characteristics, and return the consumed energy back to the grid cleanly, saving costs related to energy consumption and cooling, meanwhile eco-friendly. With modular high power density design, IT8000 provide up to 18kW in 3U space.
-
product
Battery Cell Simulator
BCS-LABCAR
The ETAS Battery Cell Simulator (BCS-LABCAR) is a Hardware-in-the-Loop system which specifically targets the signal-level test, validation, and calibration of battery management systems (BMSs). The BCS-LABCAR is a high-precision Battery Cell Simulator that emulates the behavior of individual battery cells and packs across a wide range of challenging operating conditions, e.g. cell balancing over-charging, deep discharging, or pulse operation. The system is highly modular and thus scalable to emulate battery packs from a single cell all the way up to 200 cells.
-
product
Light I-V Testing for Solar Cells
FCT-650
Advanced analysis of solar cells including light I-V and Suns-Voc data.
-
product
Road Load Data / Durability
Vehicle Durability Testing and Road Load Data AcquisitionA road load data acquisition system from Dewesoft is a perfect vehicle durability testing solution for real-drive tests or tests on the road simulator test benches. Our advanced DAQ technologies will shorten time to test dramatically and make sure you get the correct measurements right the first time.
-
product
Load Simulator
The load system is intended for testing satellite power supply systems; due to the integration with a solar array simulator and a battery simulator, it can perform validation and commissioning of satellite power supplies. The system is equipped with regenerative electronic loads and customer-specific high-power switching matrices for routing the DUT channels to the relevant loads. The individual voltages and currents for each channel can be read back via a Keysight Technologies switch mainframe.The system is equipped with high electrical power; its loads are capable of feeding the energy back into the power grid.