Product
Portable Three-Phase Meter Site Analyzer
RW-30X / RW-31X
-
RADIAN RW-30/31X Meter Site Analyzers deliver comprehensive three-phase field testing and site analysis utilizing the Radian Research RX Xytronic series reference standard as its measurement engine. The RW-30/31X provides for testing meters with integrated, precision, true three-phase voltage and current sources or using customer’s load. Choose the RW-30/31X NS (no source) model to test using customer’s load only.
-
Product
C Series Relay Output Module
Input/Output Module
The C Series Relay Output Module enables you to switch up to eight signals at 60 V maximum DC switching voltage and up to 250 V of maximum AC switching current. For quick reference, every channel features an LED to indicate the state of that channel. The C Series Relay Output Module allows for direct connection to a wide array of industrial devices such as motors, actuators, and DC devices.The C Series Relay Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
Product
68-Pin D-SUB Female to 68-Pin D-SUB Female, Twisted Pair, Shielded Multifunction Cable
199006-0R35
Multifunction Cable
The SH68F-68F-EPM Cable, sometimes referred to as SH68-68-EPM, connects NI DAQ 68-pin devices to 68-pin accessories. The SH68F-68F-EPM Cable features D-type connectors and it is available in different lengths.
-
Product
Reference Meter
ST1000
-
Shenzhen Star Instrument Co., Ltd.
The ST1000 three-phase reference meter incorporates high-precision A/D converter, DSP, wide-range measuring and embedding industrial PC technologies. It has a high accuracy of class 0.01. The voltage measuring range (phase voltage): 1V~480V, current measuring range: 1mA~120A.
-
Product
Cyber Security Testing Services
-
Cyber security testing is often also referred to as pen testing or penetration testing. Such tests validate the cyber security defences of your applications, network infrastructure and even your team members. Our cyber security testers are highly trained and certified ethical hackers.
-
Product
Meter test station
TS23
-
Calmet Smart Calibration Devices
Three phase reference standard of accuracy 0.02% (or 0.04%). It makes possible electricity meters testing on the site or in the laboratory up to 3x120A/600V
-
Product
3207a GPS/GNS Frequency and Time Reference
GlobalTyme2
-
Precise Time and Frequency, Inc.
The ptf 3207A GlobalTyme2 GNS Receiver introduces a new level of advanced capability from a second generation, based on the highly successful ptf 3203A and ptf 3204A GlobalTyme receivers.The unit is both a frequency standard and a time standard and has been used as a precision frequency reference with low phase noise, in satellite communications applications around the world.
-
Product
8-Ch 1.25 GHz, 16-bit D/A with DUC, Extended Interpolation, Virtex-6 - 6U VPX
Model 58671
-
- Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Eight 1.25 GHz 16-bit D/As- Eight digital upconverters- Extended interpolation range from 2x to 1,048,576x- Programmable output levels- 250 MHz max. output bandwidth- 4 GB of DDR3 SDRAM- PCI Express (Gen. 1 & 2) interface up to x8- Sample clock synchronization to an external system reference- Quad µSync clock/sync bus for multiboard synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount
-
Product
On-Line Gas Analysis System
Titan-OL
-
The Titan-OL is a turnkey, process-ready gas analysis system. The analyzer and sample handling hardware can be wall or frame mounted in a NEMA enclosure suitable for use in production environments, including Class I, Div. 1. The integrated sampling system is fully purgeable and can handle multiple sample and reference lines.
-
Product
Gas Filter Correlation Carbon Monoxide Analyzer
Model T300
-
The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Single Phase Reference Standard Meter
-
Signals & Systems India Private Limited
The Single Phase Portable Reference Standard (SPRS-1102) from SANDS is a portable meter test equipment that helps to calibrate the error present in the single-phase energy meter i.e. the meter under test (MUT). The SPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, phase angle etc of the meter under test. It has an LCD display and an alphanumeric keypad to suit the user. It can be interfaced with the PC for analysis. It has the capability of storing 1000 test results.
-
Product
General Performance Differential Pressure Transducers
-
These general performance Baratron® differential capacitance manometers measure the difference in pressure between the inlet tube and the reference cavity. The reference cavity can be connected to any pressure or vacuum source, or be open to local atmosphere.
-
Product
Precision Chilled Mirror Reference Hygrometers
-
Chilled mirror dew-point hygrometers provide highly accurate and stable measurements of trace moisture and humidity. The precision chilled-mirror reference hygrometers are sensitive to changes in very low moisture concentrations (less than 5 ppbV).
-
Product
Time Code Generators
-
Masterclock's time code generators provide a source of very stable time code and accurate time and date information. The GPS500 extracts timing reference from GPS satellite signals and generate time code synchronized to within less than 10 microseconds of UTC (Universal Coordinated Time). It can output IRIG-B with and without IEEE 1344 date encoding, SMPTE/EBU, NMEA 0183, Kinemetrics/Truetime, and 1PPS.
-
Product
Power Meters andCalibration Cells
-
The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.
-
Product
Hydrophone
RESON TC 4038
-
The TC4038 is a miniature probe hydrophone, specifically designed as a standard reference hydrophone for high frequencies in the range: 100kHz to 1.2MHz. The TC4038 provides a flat frequency response and omnidirectional characteristics in the specified frequency range. The sensor element has excellent stability, which ensures reliable sensitivity over long periods of time.
-
Product
Reference Grade Compact Audio Interface
Lyra 1
-
Lyra represents the pinnacle of compact audio interfaces. Packing Prism Sounds trusted, uncompromising AD/DA conversion into a compact chassis perfect for use in the studio or on the road.
-
Product
VoLTE Battery Test, Reference Solution
-
The VoLTE Battery Test, Reference Solution is a fully automated test solution for chipset vendors and device makers who need to follow operators’ VoLTE battery acceptance test plans.
-
Product
SP2T RF Pin Diode Switches To 18 GHz
-
Pulsar Microwave's 2-way switches are available in absorptive and reflective designs from 20 MHz to 18 GHz. They are also referred to as single pole, double throw and abbreviated SPDT or SP2T. These switches have a typical VSWR performance of 1.6:1 or better and input power handling of 200 milliwatts maximum. Switching time is 100 nanoseconds, and isolation of 60 dB or greater for most models. Supply voltages are +5V and -5V, with TTL logic control voltage of 0 to 5 volts.Both absorptive and reflective SPDT switches are packaged into Pulsar Microwave's SW2 outline. Configuration is standard with SMA female connectors. Voltage is applied with wire wrap feed thru terminals. The housing serves as electrical ground, and two turret terminals are installed for wiring.
-
Product
Sensor Solutions for IoT
-
Imec is a reference in the design of ultra-low power electronics, low-power algorithms to increase intelligence and data security, and in all aspects of data science. Our multi-sensor environmental monitoring platform features sensors for temperature, relative humidity, NO2, CO2, VOC (volatile organic compounds), particle matter, ambient light, sound, vibrations and presence detection. Our test platform is suitable for indoor and outdoor air quality monitoring and control, and can be used in smart buildings, smart cities and more.
-
Product
Model PS-1
16820-100
-
The Model PS1 under tank probe is designed to be used in conjunction with customer-supplied ¾” National Pipe Thread (NPT) PVC piping and the product has a ¾” (NPT) threaded end that accepts a standard coupling. Any number of pipe pieces can be combined via couplings to provide the required probe insertion length under a tank. The probe can be combined with any standard reference electrode with a ¼ x 20 threaded fitting, including the RE-5, RE-5C and RE-7 portable reference electrodes. Reference electrodes are sold separately. The sealed cable to be fed through a customer-supplied PVC pipe comprises #16 AWG wire with red colored PVC insulation and the wire length can be selected via the radio buttons in the field below.
-
Product
High-Temperature and High-PressurepH Electrodes
UltraDeg
-
Corr Instruments offers a full range of exceptionally high performance, high-temperature and/or high-pressure UltraDeg probes, including pH electrodes, reference electrodes, platinum conductivity probes, and ORP(redox) electrodes, for temperatures up to 650F (343C) and pressures up to 5100 psi (35 MPa). These probes are ideal tools for corrosion monitoring, thermodynamic or electrochemical studies in harsh environments such as steam generators, nuclear power reactors, geothermal systems, deep oil/gas wells, and super critical water systems. Many of these UltraDeg probes are built upon our innovative sealing compound, Queon, which is the only known material in the world for sealing electrical conductors in metal sealing glands or compression feedthroughs that are operable at temperatures between 400F (200C) and 650F (343C).
-
Product
Paramagnetic O2 Analyzer Optional CO2 Sensor
Model T802
-
Teledyne Advanced Pollution Instrumentation
The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time. The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases. The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points. There is no requirement for a reference gas during operation.
-
Product
T7 Fiber-Optic Cable Assembly for GPIB-140, 100 m
182805-100
Cable Assembly
2-Pin Male to 2-Pin Male, Core/Clad 62.5/125 um, 850 nm Wavelength Fiber-Optic Cable for GPIB-140A Extender - The GPIB T7 Cable, sometimes referred to as GPIB Cable, connects your system to high-speed GPIB-140A extender devices. You can use the GPIB T7 Cable with a GPIB extender to increase the cable length of your system up to 1 km without comprising the integrity of your GPIB system or requiring any application modifications. The GPIB T7 Cable is offered in different lengths.
-
Product
Saturable Spectroscopy Laser Lock Module
-
A compact, mechanically-robust laser frequency reference.
-
Product
16 Bit DDS Generator Up To 200 MHz
96xx series
-
The 96xx series DDS generators deliver the highest performance in both speed and resolution. The series includes produts between one and 24 synchronous channels. DDS – Direct Digital Synthesis – is a method for generating sine waves from a single, fixed-frequency reference clock and is widely used in signal generation applications. The DDS functionality implemented on Spectrum Instrumentation’s AWG platform is based on the principle of adding multiple “DDS cores” to generate a mul?ti-carrier (multi-tone) signal, with each carrier having its own well-defined frequency, amplitude and phase. In addition to these static parameters, there are also build in dynamic parameters like frequency slope and amplitude slope to allow for intrinsic linear changes for multiple cores.
-
Product
Source Systems AC
-
The power sources of MTS-series based on digital amplifier modules combined with frequency generator and reference device are the MTS source system. Single-phase systems (MTS1xx) or three-phase systems (MTS3xx) from 1 to more than 40 test positions are available.
-
Product
IPv6 to IPv4 Converter
-
An IPv6 to IPv4 Gateway is known by many names, including IPv4 IPv6 converter, IPv6 to IPv4 gateway, IPv6 to IPv4 network gateway, IPv6 converter, IPv6 gateway, or IPv4 converter. Some people refer to these solutions as IPv6 Compatibility tool, IPv6 compatibility appliance, IPv6 compatibility device, IPv6 transition mechanism or IPv4 to IPv6 tool.
-
Product
Complete Field Meter Site Testing Solution
7 Series
-
We raised the industry standard by introducing the PowerMaster 7 Series as a true 3-phase analyzing reference standard with internal 3-phase current and voltage source capability. The innovative design of the PowerMaster® 7 Series allows utilities to fully test a metering installation with one piece of equipment. Customer load meter testing, phantom load meter testing, CT burden and ratio testing, CT de-magnetization, PT ratio testing, and transducer testing can all be performed with one solution. In addition, vector diagrams, voltage and current waveforms, and harmonics data up to the 100th harmonic can all be analyzed to complete a true wiring verification.
-
Product
Scanning Mobility Particle Sizer Spectrometer
3938
-
TSI''s newest Scanning Mobility Particle Sizer SMPS™ spectrometer is widely used as the standard for measuring airborne particle size distributions. This system is also routinely used to make accurate nanoparticle size measurements of particles suspended in liquids. The National Institute of Standards and Technology (NIST) uses a TSI DMA to size 60 nm and 100 nm standard size reference materials.