Voltage
The tension of an electromotive force.
-
product
PS/2 Type; ATX 400W
PS400-XP2
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 20A (0.5A min)**+3.3V, 20A (0.3A min)**+12V1, 16A (1A min)**+12V2, 16A (1A min)**-12V, 0.5A**+5Vsb, 2.5A (1A min)*MTBF(hours): At 25°C, 100,000h*Safety: TUV, CS22.2 NO.60950-1, IEC, UL, NEMKO+CB, CE*Dimensions: 150 x 140 x 74 mm*Compatible with Axiomtek products: AX61221/AX61222/AX60501/AX60551/AX60552/AX61400/AX6145/AX6156/AX61492/AX61220
-
product
Optical Detector
LG-9200
The LG-9200 is a non-contact type optical detector which emits red visible light and detects the reflected light from the rotating shaft. The reflection mark is used for the detection by affixing it on the rotating shaft. It enables detection at an angle. (reflective mark: HT-011 by Ono Sokki)The LG-9200 has a built-in compact amplifier and outputs the square wave (voltage) after waveform shaping.With a compact and light weight body, performances are upgraded compared to the previous model LG-916.(LG-9200 detection distance: up to 40 mm, response speed: up to 40 m/s)
-
product
High-Voltage Test Device
PGK 150 / 5 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK H. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing of medium- and high-voltage cables* DC voltage testing of up to 150 kV output voltage with positive or negative polarity* AC voltage testing - up to 110 kV for switchgear, busbars and insulating elements* Easy-to-maintain 2-piece design
-
product
MOTORIZED VARIABLE TRANSFORMER CONTROLLED POWER SUPPLY
Motorized Variable Transformer Controlled Power Supply, P/N 18534PSInput: 460 VAC, 3 PH, 60 HzOutput: 0 to 250 VDC, 200 Amp max.Variable Transformer is used to vary the output. SCR controller is not used, as it generates harmonics.Input control is 0 to 3.6 VDC.Indoor enclosure.Output voltage and current feedback as 4/20 mA for PLC interface.All input/output connections are inside the enclosure
-
product
Coaxial Power Detector
RF Lambda’s coaxial power detectors are used to convert the RF power level to a DC voltage for signal power measurement. They offer wide band operation, fast response time and compact size.
-
product
TightSight™ Clamp Meter, 1000A AC/DC W/TRMS
61-775
*TightSight™ second display*Tapered jaws with hook tip*True RMS current and voltage*AC/DC voltage*Audible continuity*High frequency rejection**Peak hold*Max/min hold*Data hold*Selectable audible and visual alerts when potentially hazardous voltages are detected at the probe terminals*Selectable auto power off*Backlit display*Low battery indicator*Reads accurately on noisy electrical circuits
-
product
Single Channel Potentiostats
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
product
High Voltage Film Capacitors
High Voltage Pulse Capacitors, High Voltage Energy Discharge Capacitors, High Voltage Filter Capacitors and Customized High Voltage Capacitors
-
product
Optical Delay
ODL
The Peregrine Optical Delay Line (ODL) provides an exceptional combination of precision, speed, and optical stability at a low price. It is ideally suited for pump-probe experiments and autocorrelation measurements (both interferometric and intensity methods). Advanced voice coil technology allows the ODL to be positioned anywhere in its travel range to within 150 nm. That’s 1 fs for a double-pass configuration. The response time is as short as 1 ms. Our 1-cm-travel ODL is interferometrically stable (measured using a 650 nm laser). No backlash, no hysteresis and no drive trains to wear out as with stepper motors. It’s convenient–the ODL can be positioned using digital commands, an analog voltage or a combination of the two. Two 16-bit on-board analog-to-digital converters simplify data collection. Digital inputs and outputs allow master or slave clocking. An executable Windows application is provided to get you up and running in minutes. In addition, DLLs and LabVIEW Vis for integration into your software are also included.
-
product
25-Pin D-Type Female Straight PCB Mount
40-963-025-SF
Accessory allows a user to create their own PCB based termination solution mounted directly on the front of the product or on the end of a cable. Interfacing PCBs should be designed with suitable clearances for the voltage the application requires. 25-Pin Female connectors can be directly mated to a corresponding Pickering Switching Module while Male versions can be used to interface to a Female cable assembly termination.
-
product
DC Power Supplies
XG 850
AMETEK Programmable Power, Inc.
The Sorensen XG Series is an 850 Watt, 1U half-rack DC power supply. The XG Series is the new standard for powerful, programmable DC power systems. Designed for test, production, laboratory, OEM and quality assurance applications, the XG Series provides a wealth of features to ensure accuracy and greater efficiency. It puts clean, reliable power at your disposal and delivers stable, variable output voltage and current for a broad range of development, test and system requirements.
-
product
Digital (1kV up) H.V. Insulation Tester
4103 IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV)
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Measures insulation time test.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.
-
product
Power Quality Analyser
PM1000
The PowerMaster 1000 Single Phase Logger is a 3-channel data logging system built into an easy to carry housing. It is ideal for responding to residential voltage complaints and power consumption problems. It is particularly useful for troubleshooting.
-
product
Open Source Logic Analyzer
Logic Pirate
8 channels 256,000 Samples recording size 20 MHz sampling speed, can potentially be overclocked to 60 MHz No compromise on sample size when combining different speeds or number of channels Simple configurable edge detection triggers on all inputs (simple OR trigger) Configurable ratio of samples from before and after the trigger (rolling sample buffer) 5 V tolerant inputs (LOW-level voltage < 0.8 V, HIGH-level voltage > 2.0 V) About 500 kB/s transfer speed to the PC (256 kSamples take about 0.5 seconds) Data capturing can be stopped from the host software anytime Cross platform host software for Windows, OS X, and Linux DIY-friendly 0603 parts and SOIC packages used on a 2-layer board On board 3.3 V regulator can supply up to 400 mA to an external circuit Tiny 3cm x 3cm PCB Firmware updates via built-in USB bootloader Probe cables and acrylic case available from Seeed Studio Open source PCB (EAGLE) and firmware files
-
product
Digital Earth Resistance Tester
ERT-1501
Electronic Digital Earth Resistance Tester is direct replacement of the conventional hand generator type tester. It is designed for measurement of the resistance of earthing used in the electrical equipment as well as for measurement of ground resistivity. It can be used for measurements of the other low regular and liquid resistances. It can also be used for measurement of voltage AC, voltage DC and resistance. This instrument finds wide application for testing earthing installation in power based industries, telecommunication networks and electrical traction systems etc.
-
product
Auto-Ranging Digital Clamp Meter
DCM401
Expert Quality, auto and manual ranging clamp meter capable of voltage, current, resistance, diode, continuity, capacitance, frequency, duty cycle and temperature testing. Maximum jaw - opening diameter of 36mm, backlit LCD screen, auto power off and a useful inspection light. Supplied with test leads, temp probe, case and 3 x AAA batteries.
-
product
Temperature/Process Controller
4B
The Series 4B 1/4 DIN Temperature/Process Controller is designed to accept thermocouple, RTD, current or voltage input and provide dual outputs for control. Available outputs include relay/relay, voltage pulse/relay, current/relay, or linear voltage/relay
-
product
DC System Power Supply, 80V, 9.5A, 760W
N5748A
The single output, 760W N5748A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current.
-
product
Functional Test
For a functional test the WEETECH test systems simulate reality and enforce switching operations that can only be tested in an embedded condition. In doing so voltages, currents, time intervals and other measurement categories are adjusted and switching sequences are processed in a way, it would happen in reality.
-
product
C Series Strain/Bridge Input Module
The C Series Strain/Bridge Input Module works with higher-channel-count, dynamic strain measurement systems. Modules can acquire measurements from up to eight channels, with compatibility options for quarter-, half-, and full-bridge sensors. The C Series Strain/Bridge Input Module is ideal for application channels requiring measurements at particular times, such as impact tests. It includes built-in voltage excitation, as well as transient isolation for high-common-mode noise rejection and improved safety.The C Series Strain/Bridge Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
NI-9218, 51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module
783367-01
51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module - The NI‑9218 is designed for multipurpose measurements. It offers built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. Each channel is individually selectable, so you can perform different measurements on each channel. The NI‑9218 is ideal for creating universal test systems for automotive, off-highway, and data-logging systems.
-
product
50-Pin D-Type Connector, Right Angle PCB
40-963-050-RF
Accessory allows a user to create their own PCB based termination solution mounted directly on the front of the product or on the end of a cable. Interfacing PCBs should be designed with suitable clearances for the voltage the application requires.
-
product
Triple Output Power Supply
E36300 Series
The E36300 Series triple output power supply is ready for your bench application. With low output ripple/noise and accurate voltage/current measurements, you can test with confidence. Power multiple voltage buses with clean, reliable power, view voltage and current on all outputs simultaneously. You have access to advanced features such as data logging, output sequencing, list mode, and output coupling.
-
product
PXI 2A Multiplexer, 1-Bank, 64-Channel 2-Pole
40-614-016
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
product
Power Supply 650W
UEP10M52-53 / CEP10M52-53
The UEP10M52 series is a UEP10M variation with a maximum current output on +6V or -6V (asymmetric) and without +/-12V for use in CERN type CAMAC crates with a maximum 650W power output. The power supply has all the standard features of the UEP10 family as high precision and lowest noise DC outputs and a cut-off protection for overload, over- / and under voltage and over temperature failures.
-
product
PXI 19 x DPST Reed Relay 2 Amp
40-136-212
The 40-136-212 19xDPST reed relay module is part of our range of medium power, general purpose relay modules which are capable of switching voltages up to 200V and current up to 2A.
-
product
Field Strength Meter
FIM-72A UHF
The Model FIM-72A is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-72A is suitable for practically all types of RF emission measurements in the 450 MHz to 960 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and meter dynamic range of either 20 dB or 60 dB. A dc analog voltage, proportional to meter indication, is provided for driving a chart recorder or similar device. A leveled output from the calibrating generator is available for measuring cable insertion loss, filter response, amplifier gain, VSWR, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.
-
product
PCI-5122, 100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device
778758-01
100 MHz Bandwidth, 100 MS/s, 14-Bit PCI Oscilloscope Device—The PCI‑5122 high-resolution oscilloscope device has two channels with greater than 75 dBc spurious‑free dynamic range (SFDR) and flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for both time-domain and frequency-domain applications that require high-resolution, low-noise measurements with up to 100 MS/s and 100 MHz of analog bandwidth.
-
product
Battery Simulator
1200
The Battery Simulator 1200 provides isolated channels to simulate battery sink and source characteristics often used for testing a Battery Management System (BMS). The instrument can be used standalone with the soft front panel, or integrated into a larger test system. Its proper industrial cooling and cell channel isolation allows units to be easily stacked, providing solutions with over 200 channels of simulation capability. The built-in channel voltage and current readback reduces the need for external monitoring equipment.
-
product
Electrochemistry
Modular Line
The Modular Line of instruments consists of a range of instruments to suit any requirements in electrochemical research, from low to high voltage and from low to high current.