Thermocouple Calibrators
-
Product
DC/10 MHz 50 GHz USB Thermocouple Power Sensor
U8487A
Power Sensor
The U8480 series is Keysight's first power sensor with the capability to measure down to DC (only applicable for U8481A/85A). Now, with an expanded frequency range up to 50 and 67 GHz, the U8480 series allows you to make fast and accurate high frequency power measurements in applications ranging from PNA/MXG calibration to high volume manufacturing.
-
Product
Optical Calibration
-
PIMACS which acquired the Korean Laboratory Accreditation Scheme(KOLAS) provides calibration service for your developments & products with a wide range of light measurements, traceable to international standards. We also supply the various optical calibration systems to the customers who want to acquire the qualifications of an optical testing laboratory.
-
Product
Acoustic Emission Calibrator
-
AE calibrator is similar to a simple signal generator, it can generate a variety of controlled waveform signal, different types, different amplitude and different frequency. It can help users calibrate acoustic emission detection equipment before acoustic emission detection.
-
Product
MAX31855 K-Type Thermocouple Sensor Breakout
SEN-30001-KDP
-
Breakout board for the MAX31855K digital thermocouple interface IC. Measured temperature range is -270C-1372C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 1x5 pin header and four mounting holes for standoffs and 4-40 screws. It does not contain a mini thermocouple connector.
-
Product
Thermocouple Power Sensors
N8488A
Power Sensor
N8488A power sensor has the widest frequency range among N8480 power sensors offering from Keysight.
-
Product
Argon Calibration Source
AR-1
-
The AR-1 produces low-pressure argon emission lines from 696-1704 nm for use in performing fast, reliable spectrometer wavelength calibrations.
-
Product
Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
SEM1605/P -
-
SEM1605/P - Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
-
Product
Trace-Level Dilution Calibrator
Model T700U
-
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
Product
100-Amp Current Calibrator And AC/DC Transconductance Amplifier
2555A
-
World’s Leading Precision 100-Amp AC/DC Current Standard - For 30 years Valhalla Scientific’s design has proven rock-solid reliability in metrology labs worldwide. The 2555A is a calibration powerhouse with wide-ranging applications and unsurpassed quality.
-
Product
Differential Calibration Substrates
-
The GGB Industries, Inc., line of DIFFERENTIAL CALIBRATION SUBSTRATES allows the user to calibrate any GGB Industries, Inc., microwave Picoprobe at the probe tip. The underlying principal of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected.
-
Product
Mineral Insulated Thermocouples IEC
-
Durable Mineral Insulated type thermocouples to suit a wide range of temperature measurement. Various probe types, lengths and diameters available.
-
Product
Calibrator
-
Sanwa Electric Instrument Co., Ltd
Is an equipment used to adjust an instrument accuracy, often associated with a specific application: temperature, pressure, weight.
-
Product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (m) 50 Ohm
CK518A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Calibration Services
-
API Measurement Services offer on-site machine tool and industrial robot calibration and volumetric error correction services. Laser trackers can be calibrated at our calibration laboratories or accuracy certified in the field. A2LA ISO 17025 certified.
-
Product
Calibration Hand Pumps
-
Nagman Instruments & Electronics Pvt. Ltd
Calibration hand pumps are the most cost-effective way to calibrate pressure devices. At Nagman, you can find Calibration hand pumps that are the best in the industry. Calibration hand pumps are used to generate pressure. Which can be hydraulic, pneumatic, or vacuum. This kind of pressure generation is done during testing and calibration applications. We also offer calibration pumps that can help in high pressure to low pressure calibrations. Visit Nagman website and browse through the range of calibration hand pumps to find the right device for your calibration needs.
-
Product
Standard Ratio Box For Calibration
ST-105
-
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
Product
6-Ch Thermocouple Input EtherCAT Slice IO Module
AMAX-5018
-
Channels: 6 differentialInput Type: V, mV, ThermocoupleInput Impedance: >2MΩVoltage Range: ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 VResolution: 16-bitFSR accuracy: 16-bit with ±0.1% @25°CSample Rage: 100 Sample/Second (per channel)
-
Product
MAX31856 Thermocouple Sensor Arduino Shield
SEN-30007-K
-
Quad channel thermocouple Arduino shield based on the MAX31856 universal digital thermocouple interface IC. This is an exciting update of the MAX31855, with improvements in resolution (19 vs 14 bits), on-board temperature reference (6 vs 4 bits), and compensation (fully compensated vs nonlinear correction required). The MAX31856 is interfaced via 4-wire SPI with options for interrupt triggering. An LDO and a high-speed level shifter are included on ALL device pins to allow interfacing with to any Arduino - both 3.3V and 5.0V variants - without sacrificing device performance in any operating condition.
-
Product
Blackbody Calibrators
-
Omega offers a diverse portfolio of blackbody calibrators used to calibrate infrared pyrometers. Blackbody calibrators use a high emissivity target plate or target cavity to minimize error.
-
Product
Volume Calibration
-
Trescal provides full Volume Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Volume Calibration services can be delivered at your site or at our lab. Accreditations for our volume calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
4-in-1 OSLT Calibration Kit, DC to 70 GHz, Type-1.85 mm (m)
CK058M
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
3.5mm Short Open Load Thru 4-in-1 Analyzer Calibration Kit
-
Fairview Microwave’s portable calibration kits consist of two models, both with a compact, lightweight, 4-in-1 design package. These short-open-load-through (SOLT) calibration kits feature precision 3.5mm connectors, have a 26.5 GHz calibration capability, gold plated short-open-load-thru and include a handy lanyard. These SOLT calibration kits have a phase deviation of +/-2 degrees maximum and return loss of 30 dB minimum and feature an impedance level of 50 Ohms nominal. They are ideal for telecommunications, military electronics, automotive, medical, aerospace and consumer electronics industries.
-
Product
7-Ch Thermocouple Input Module With Independent Input Range
ADAM-5018P
-
Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 HzSampling Rate: 10 samples/sec. (total)High Common Mode: 2000 VDCIsolation Voltage: 3,000 VDCFault and Overvoltage Protection: Withstands over voltage up to ±35 VCMR @ 50/60 Hz: 92 dB minInput Impedance: 20 MΩ. (Build-in 120 Ω Register for Current Input)Built-in TVS/ESD ProtectionFilter function: YesChannels: 7 differential with Independent Input Range
-
Product
Coaxial Calibration Kits
-
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Rosenberger offers the following types of calibration kits with a range of coaxial connector series for vector network analyzers (VNAs). All Rosenberger calibration kits can be used from DC to their maximum frequency. Full version with adaptors and sliding loads for variable measurements Industrial version for standard measurements LRL and TRL version
-
Product
Calibration Kit
FMCK1000
-
Designed to withstand daily use in high-traffic environments such as in the testing lab or on the production floor. This cost effective calibration kit provides reliable and accurate instrument tuning for all of your test and measurement requirements. Applications: VNA, Full 2-Port CAL VNA, Thru CAL VNA, Substitution CAL method Test & Measurement Lab Equipment Accessories Engineering Test and Evaluation General Purpose Test and evaluation.
-
Product
Balance Thermocouple Power Sensor, DC To 18 GHz
N8481S
Power Sensor
The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.
-
Product
Mercury Argon Calibration Source
HG-1
-
The compact, low-cost HG-1 Mercury Argon Calibration Source is a spectral wavelength calibration source for UV-VIS-Shortwave NIR spectrophotometric systems.
-
Product
OTDR Training & Calibration Solution
-
In addition to network simulation applications, the Fiber Lab 800HE from M2 Optics is a professional optical fiber platform that enables technicians to practice using an OTDR to find splices, faults, or bad connections in a length of optical fiber. In addition to training, it can also be used by equipment servicing teams to calibrate OTDRs with fiber that includes pre-determined events at known points.
-
Product
Thermocouple Simulator Module for SLSC
Simulator
Bloomy’s 8-Channel Thermocouple Simulator Module provides eight channels of galvanically-isolated thermocouple simulation and simulates types E, J, K, M, N, and T thermocouples. High-precision digital-to-analog converters which are isolated from each other and from system power provide sub-microvolt resolution and accuracy. Built-in switching provides open-circuit faults as well as switching to system calibration resources.





























