Thermocouple Calibrators
-
Product
Calibration
-
Calibration of a measuring tool is an operation that allows an assessment of the accuracy of the measurement, and the adjustment of the measuring tool so that it is more accurate. In scientific formulation, calibration makes it possible to evaluate the measurement error.
-
Product
Broadband Calibrated Noise Sources
-
Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.
-
Product
Microphone Calibration Workstation
9350C
-
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
-
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Calibrator, Calibrated w/D & U, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL DU
-
The 72-6694 CAL DU from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Basic Quad K-Type Analog Thermocouple Amplifier
SEN-30103-K1
-
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036E
Mechanical Calibration Kit
The Keysight 85036E economy calibration kit contains precision 75 ohm type-N male fixed termination and a one-piece 75 ohm type-N open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. The kit is specified from dc to 3 GHz.
-
Product
J-Type Thermocouples Wire, Fiberglass (32 deg F to 900 deg F) 1 m
745690-J001
Thermocouple Contact (ITA)
J-Type Thermocouple, 32°F to 900°F Temperature Sensor - The J-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the J-Type Thermocouple and acquire synchronized temperature data in units of degrees. The J-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Compensation Block for Thermocouple Simulator Modules
40-965-912
-
The Compensation Block is a accessory specifically designed for the 41-760 and 41-761 Millivolt Thermocouple Simulator modules. This block will give the user the temperature of the front panel junction of the module to cabling. This data can then be combined with other factors, temperature on the other end of the cable for example, to compensate the thermocouple hence increase the accuracy.
-
Product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm
CK521A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Calibration & Maintenance
-
Dou Yee Enterprises (S) Pte Ltd
The need and importance of regular maintenance of your equipment and test instruments is critical in ensuring continuous productivity, production of high quality products.With this in mind, we take pride in providing efficient after sales maintenance, repair, calibration service and product support to all our valuable customers to minimize equipment down time.Apart from having a team of consistently well-trained service engineers, our fully equipped laboratory are located in various parts of the world, such as Singapore, Taiwan, China etc. All service and calibration procedures are adhere strictly to manufacturer’s specifications and international standard.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
-
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Cable Assy 78-Pin D-Type Female to 16 x Mini Thermocouple Plugs, 1m
A078DFR-16M002T5A100
Cable Assembly
This 78-pin D-type thermocouple cable assembly is terminated with 16 male mini thermocouple plugs. It is constructed from 7/0.15 (26AWG) silver plated copper wire and screwlocks are provided to secure the D-type to its associated products.
-
Product
Electrical Calibration
-
Trescal provides full Electrical Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Electrical Calibration services can be delivered at your site or at our lab. Accreditations for our electrical calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Relative Humidity Calibration Services
-
PST have calibration laboratories offering Relative Humidity calibrations in six locations across the globe.
-
Product
Gauge Type T Thermocouple Wire
W-TW-30
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
EMC Calibration
-
Trescal provides full EMC Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. EMC Calibration services can be delivered at your site or at our lab. Accreditations for our emc calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
(94dB & 114dB)Sound Calibrator
AWA6221A
-
Hangzhou Aihua Instruments Co., Ltd.
*Comply with IEC 60942 class 1*Pocket size, portable unit *Frequency 1000 Hz, give independence of weighting*Sound pressure independent of microphone equivalent volume
-
Product
Horizontal Calibration Instruments (Lab)
Labconcept Nano
-
The Labconcept Nano is a new reference in the field of dimensional metrology. It integrates 40 years of knowledge and continuous improvement. It is a remarkable instrument for all measuring tasks that require extremely high accuracy.
-
Product
Dry Block And Bath Calibrators
-
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
Product
E-Type Thermocouple, 32°F to 900°F Temperature Sensor
745690-E001
Thermocouple Contact (ITA)
E-Type Thermocouple, 32°F to 900°F Temperature Sensor - The E-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the E-Type Thermocouple and acquire synchronized temperature data in units of degrees. The E-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
DC/10 MHz – 18 GHz USB Thermocouple Power Sensor
U8481A
Power Sensor
The U8480 series is the fastest USB thermocouple sensor in the world without compromising the best in class linearity of the legacy 8480/N8480 series thermocouple sensors, all in a compact USB based form factor
-
Product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
-
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Calibration & Repair Services for Instruments in Process Control
-
Meeting customer needs is our number one priority. Hastings Instruments offers free technical support as well as personalized one-on-one customer service through a diverse organization of field Customer Service Representatives and Distributors. We have more than 50 field Customer Service Representatives that are situated to provide local support throughout the world.Additionally, reaching our Customer Service Department is only a toll-free number away (USA) and is available for your convenience. Faxing or E-mailing your question first will assure that it is reviewed before you speak to a Customer Service Representative. Also, following the steps listed in our trouble shooting guides (included in each product instruction manual) may help direct you to the appropriate department before you pick up the phone to call.
-
Product
Automatic Calibration Module
ACM2509
-
ACM2509 is an automatic calibration module that can be used with all CMT Vector Network Analyzers operating in frequency range up to 9 GHz. It is a fully automatic USB-controlled and powered electronic calibration module. Minimizing the number of steps required by technicians reduces the risk of human error and expedites the calibration process. Automating the calibration routine also reduces wear and tear on the analyzer and RF cables. To perform full two-port calibration, each end of the ACM need only be connected to the analyzer once, as opposed to seven connections with a traditional calibration. The ACM also contains a factory characterized 20dB in-line attenuator which acts as a simulated device under test (DUT). The confidence check feature loads the factory stored DUT into memory so proper calibration can be verified.
-
Product
Temperature Calibration
-
In our temperature lab we have the capability calibrate a wide range of temperature products such as catering food probes from deli to restaurant, industrial systems for manufacturing and quality checks using thermocouples surface probes or insertion probes we also calibrate IR (Infrared) thermometers.
-
Product
Calibration Substrates
-
The GGB Industries, Inc., line of CALIBRATION SUBSTRATES allows the user to calibrate any GGB Industries, Inc., microwave Picoprobe® at the probe tip. The underlying principal of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected
-
Product
Photometric Ozone Calibrator
Model T703
-
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
Product
Calibration Services
-
Your CLIO hardware can be furnished with (or be submitted for) a SIT Certificate of Calibration. This document, produced by a laboratory accredited by the Italian Calibration Service, reports measurement data of the primary quantities generated and analyzed by the instrument (AC Voltages) traceable to National and International Standards. This document is usually requested for ISO compliance.





























