Thermocouple Calibrators
-
Product
Microwave Measurements & VNA Calibrations
-
Rosenberger Hochfrequenztechnik GmbH & Co. KG
For microwave measurements and VNA calibrations, Rosenberger develops, manufactures, and provides test & measurement products which meet the highest demands of industrial test applications. These include high-performance VNA test cableswith outstanding phase and amplitude stability, a variety of test port adaptors for VNA applications up to 110 GHz, very robust interchangeable high mating cycle port connector systems, and test devices – from low-frequency devices for simple measurements to components permitting high-precision broadband measurements.
-
Product
Ice Point Calibrators
-
These ice point calibrators are designed to accurately calibrate probes at the freezing point of water. These devices have multiple thermowells to calibrate multiple sensors simultaneously.
-
Product
Transducer Calibration
m+p SensCal
-
Regular transducer calibration is an essential requirement for maintaining the accuracy, reliability and repeatability of the results obtained from a measurement system. m+p international’s m+p SensCal program provides a quick and simple process for calibrating accelerometers (piezo-electric with charge output or IEPE, piezo-resistive, capacitive) in your laboratory, as well as velocity or displacement transducers.
-
Product
Pressure Calibration
-
We make pressure calibration easy! All you have to do is hand us over your gauge or meter! We’ll look after the rest, half inch, quarter inch, brass or steel fitting, we have the adapters to make it work.
-
Product
Electrical Calibration
-
Beijing GFUVE Electronics Co.,Ltd.
Checking condition , performance , sensitivity and accuracy of any electrical device.
-
Product
Process Calibrators
-
AMETEK Sensors, Test & Calibration
Our process calibrators include innovative handheld multifunction calibrators, multi-channel scanners, and handheld loop calibrators and power sources. Our multifunction calibrators feature a new large full color display with an advanced simplicity, easy-to-use interface. The multi-scanner is perfect when there is a need to create traceable documents for sensor calibrations. Calibrate 16 types of RTDs, and 13 types of thermocouples with our handheld calibrators.
-
Product
Power Measurement And Calibration
-
Portable, rugged and battery operated, Arbiter Systems® Power System Analyzers are revolutionizing measurements of instrumentation, relaying and metering circuits. Built with safety-first in mind, all products include multiple grounding technologies to protect against shock. Software and firmware is available to manage and analyze the data in real-time or post-analysis via computer.
-
Product
Open-Short-Load RF calibration kits
-
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
Product
Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit
72-7755 CAL
-
The 72-7755 CAL from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.
-
Product
Test & Calibration
-
Gamma Scientific is ISO/IEC 17025 accredited by NVLAP (NVLAP lab code 200823-0). In addition to assurance of measurement accuracy, accreditation ensures traceability to known standards, provides international acceptance of measured values, and is important for compliance purposes for your own ISO/IEC certifications. Our state-of-the-art, ISO 17025 accredited calibration laboratories in San Diego, California offer a range of test and calibration services including:
-
Product
Pressure Calibration Custom Systems
-
Our custom systems integrate standard Fluke Calibration products, pressure generation and control accessories and/or data acquisition hardware to meet customer requirements. Systems may be mobile calibration carts or rack mounted instrument panels or benches. 7250-sys Ruska gas pressure controller system, and engineered systems customized to fit your application needs.
-
Product
RF Calibration Equipment
-
Bird’s legacy in RF calibration runs deep—dating back to our early days supplying calorimeters for high-power applications. Today, that expertise lives on in our advanced calibration equipment, trusted by labs, manufacturers, and service providers around the world.
-
Product
Multifunction Calibrator 15 ppm Basic Accuracy
MC142
-
Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.
-
Product
Hydraulic Calibration for Load Cell
HLCS-10000
-
Jinan Testing Equipment IE Corporation
The Hydraulic Calibration System is specially designed for the calibration of load cells with higher capacity. The Calibration for Load Cell can calibrate the load cell within +/-1%.
-
Product
Calibration Modules and Kits
-
Keysight Calibration Modules achieve more precise and accurate measurements for your testing needs. Regular calibration is required to ensure your high-performance measurement equipment is operating to its specified performance, and our Calibration Modules and Kits make the calibration of your equipment fast, easy, and accurate.
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
Power and energy calibrators
-
Three or single phase electric power/energy calibrator with power quality functions for calibration and testing of grid measuring appliance like power meters, power transducers or power quality analysers.
-
Product
Calibration Standards
-
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.
-
Product
DC/10 MHz 67 GHz USB Thermocouple Power Sensor
U8488A
Power Sensor
The U8480 series is Keysight's first power sensor with the capability to measure down to DC (only applicable for U8481A/85A). Now, with an expanded frequency range up to 50 and 67 GHz, the U8480 series allows you to make fast and accurate high frequency power measurements in applications ranging from PNA/MXG calibration to high volume manufacturing.
-
Product
Thermocouple Temperature Data Logger
TCTemp2000
-
The TCTemp2000 is a thermocouple temperature data logger perfect for applications requiring instant remote readings of temperature. The 8-button keypad and large LCD provide convenient access to current data and data logger setup. This data logger has an internal temperature sensor and one external input for J, K, T, E, R, S, B and N type thermocouples. Additionally, memory and battery levels, external power status, sampling and recording status are shown on the LCD.
-
Product
30:1 Spot IR Thermometer with Type K Thermocouple
FLIR TG56
-
The FLIR TG56 provides non-contact surface temperature readings so you can quickly and easily take measurements in places that are out of reach. Providing a distance-to-spot ratio of 30:1, the TG56 can measure smaller targets from a safer distance. The thermometer gives you control to view your current reading and last two temperature readings simultaneously, and the color screen makes it easy to navigate and select settings.
-
Product
Calibration Lead - Precision Resistor Modules
40-975-037-02-1m
Cable Assembly
The cable assembly is specifically designed to connect to the 37-Pin D-Type calibration port located on the front panel of Pickering Interfaces Precision Programmable Resistor Modules 40-293 and 50-293 enabling calibration via an external DMM.
-
Product
16 Channel Isolated Thermocouple And Voltage Measurement Instrument
EX1401
-
The EX1401 delivers accuracies of ±0.20°C, 1000 V channel-channel isolation, built-in self-test capabilities, and independent 24-bit ADC’s per channel. Its ability to acquire data at 20K samples/second/channel allows its usage in high-speed temperature transient applications. Deploy it in a variety of applications, including automotive and battery testing, jet engine testing, highly accelerated life test/highly accelerated stress screening (HALT/HASS), and health monitoring. It can be used in any test environment that requires accurate temperature measurement and repeatability. Parallel data storage and standalone autonomous operating modes further expand the utility of this versatile instrument.
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
Product
3.5mm Short Open Load Thru 4-in-1 Analyzer Calibration Kit
-
Fairview Microwave’s portable calibration kits consist of two models, both with a compact, lightweight, 4-in-1 design package. These short-open-load-through (SOLT) calibration kits feature precision 3.5mm connectors, have a 26.5 GHz calibration capability, gold plated short-open-load-thru and include a handy lanyard. These SOLT calibration kits have a phase deviation of +/-2 degrees maximum and return loss of 30 dB minimum and feature an impedance level of 50 Ohms nominal. They are ideal for telecommunications, military electronics, automotive, medical, aerospace and consumer electronics industries.
-
Product
Thermocouple Data Logger
TGU-4550
-
The Tinytag Ultra 2 Thermocouple data logger uses a thermocouple sensor for the cost-effective monitoring of temperature in a wide variety of applications.
-
Product
Thermocouple Contact, ITA, Constantan, Type T(°C)
610113149
Thermocouple Contact (ITA)
Primary mating contact 610113148.
-
Product
Light / Lux Meter, Calibrated w/D & U, 50000 lx, 100 lx, 4 %, 185 mm, 78 mm, 38 mm
72-7250 CAL DU
-
The 72-7250 CAL DU from Tenma is a digital light meter with RS232 capability. It has custom one-chip microprocessor LSI circuit which ensures high accuracy. The meter features 13mm (0.5”) super large LCD display with contrast adjustment for best viewing angle, data hold and auto power off. It records maximum, minimum and average readings with RECALL facility. The 72-7250 has RS-232 PC serial interface, user selectable lighting type (tungsten, fluorescent, sodium or mercury, daylight) and zero adjustment by push button. The meter operates from 9V battery.
-
Product
Calibration Services
-
Mors Smitt has a professional calibration center. All electrical measurement equipment can be calibrated (for example; multimeters, current clamps, temperature meters, installation testers, power meters, safety testers, etc.).
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, Type-N, 50 Ohm
85032F
-
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.