Radiated Immunity
See Also: Immunity, Immunity Test
-
Product
Radiated Immunity Test System
-
Beijing KeHuan Century EMC Technology Co,.LTD
Radiation Immunity Test System.
-
Product
Immunity DC
PGA 1240
-
The power generator PGA 1240 is suitable for EMC testing in accordance with standard IEC / EN 61000-4-16 in the frequency range from DC to 300 kHz.
-
Product
Immunity
RF coupling
-
is used for the conducted measurement of the immunity according to IEC 62132-4.
-
Product
Immunity
EFT coupling
-
s used for direct-contact measurements of impulse immunity in IC pins, according to IEC 62215-3 and IEC 61000-4-4.
-
Product
Radiation Detectors
-
A radiation detector is a device for measuring nuclear, electromagnetic or light radiation. A nuclear radiation detector identifies nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a geiger counter, a nuclear radiation detector consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or nuclear radiation detector.
-
Product
Radiation Detectors
-
High Purity Germanium (HPGe) DetectorsSilicon Charged Particle DetectorsScintillation DetectorsORTEC is a leading supplier of solid-state, high resolution, semiconductor radiation detectors. These radiation detectors are used in research, commercial industry, environmental protection, health and medical physics, as well as homeland security to detect gamma-rays, X-rays, and charged particles.
-
Product
Immunity
ESD coupling
-
is used for conducted coupling of Langer ESD pulses (200ps rise time) into ICs.
-
Product
Electromagnetic Immunity Scanner
SmartScan BASIC
-
The BASIC is manually operated system for performing susceptibility scanning at the system level with minimal data storage capability. This system includes:1. Up to 8kV (optional. 4kV base) pulse generator for ESD susceptibility testing- Camera and camera shutter to take DUT picture and failing spots- Control computer2. Up to 8kV Probe Sets:- 1mm Hx/y Field Probe- 5mm Hx/y Field Probe- D=8mm Hz Field Probe- D=8mm Ez Field Probe- Contact API for custom design probes3. Manual input of testing location and failing condition over the DUT to be included in final report.
-
Product
Radiated Emission
-
High accuracy CISPR 16-1-1 EMI receivers and high precision calibrated antennas for radiated emission measurements.
-
Product
Solar Radiation Sensors
-
The solar radiation sensors that Campbell Scientific offers come in a variety of designs: pyranometers, net radiometers, quantum sensors, and pyrheliometers. These sensors measure various aspects of the energy imparted by the sun on the Earth’s surface. A leveling fixture fitted with a bubble level may be required to accurately install solar radiation sensors.
-
Product
Optical Radiation Meter
ORM400
-
The ORM400 Optical Radiation Meter has a USB 2.0 interface and is supplied with powerful calibration features and data display functions. It is ideally suited to display the measurements from the DH400 range of detectors as well as third party current generating detectors.
-
Product
Immunity Testing Systems
CIS Series
-
The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes an ACS series power amplifier, coupling/decoupling Network (CDN), directional coupler, 150Ω to 50Ω adapters, power attenuators, cables and [optional] CSAT software. These systems, when properly configured, are capable of testing your products to all levels given in IEC 61000-4-6 up to 230 MHz. You can choose from three systems. Follow the links below for detailed information, including a comprehensive datasheet listing system specs.
-
Product
Radiation Meters
-
A radiation meters is a device designed for measuring varying types of radiation. These devices are portable and are used to inspect personnel, equipment, and facilities for radioactive contamination by measuring the emission of certain radiation particles. They are used to measure external or ambient ionizing radiation field to assess the direct exposure hazard.
-
Product
Radiation Resistant Resolver
-
Computer Conversions Corporation
Computer Conversions GT Transducers are brushless, Electromagnetic, Rotary Sensors used to provide Precise Absolute or Incremental Position, and Velocity feedback in harsh environments. All Computer Conversions Transducers are continuous rotation, bidirectional, and electronically passive devices (no electronic components to degrade or fail), that require zero maintenance, and may be installed in virtually inaccessible locations.
-
Product
RF swept immunity package
EMiSweep
-
This is a flexible Windows immunity package which provides the utilmate flexible Graphical User interface. Other visual aids provides a swept as well as spot frequency assessment.
-
Product
Radiation Dose Testers
-
Handheld Radiation Dose Tester with high sensitive GM counter sensor, combined Beta(β ), Gamma(γ), and X-ray radiation detection. It is widely used in home decoration, radiation processing enterprise, health and epidemic prevention, radiation therapy, import and export inspection, building materials, petrochemical, geological survey, scrap steel, industrial nondestructive testing and other environments existing ionizing radiation, personal radiation dose supervision and protection occasions.
-
Product
Radiating Loops
-
The magnetic, handheld coil was designed to generate defined mag-netic fieldstrength in the frequency range from DC up to 5 (7) MHz. The main application is immunity testing against magnetic fields.
-
Product
Optical Radiation Safety Test
EN62471-C
-
IEC62471-2006(CIE S009) Photobiological Safety of Lamps and Lamp System and IEC TR62471-2(2009) Guidance on Manufacturing Requirements Relating to Non-laser Optical Radiation Safety have be published addressing hazard to human (mostly eye and skin), and are completely suitable to assess the optical radiation safety of non-laser sources, such as LED products, UV radiation in general lighting products and etc.
-
Product
The Modern Personal Radiation Detector
D3S PRD
-
The D3S PRD personal radiation detector is a high-speed PRD or SPRD replacement that is a cost-effective radiation detection and preliminary identification device for first-line users. It fits on your belt or even in your pocket giving you radiation alerts for gamma and neutron radiation plus the ability to identify what isotopes have been found. It is the only PRD that detects the presence of radiation and also displays the isotope identified and it does all this in seconds.
-
Product
Radiator Mounted Load Banks
RD-Series
-
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
Product
Gamma Radiation Detector
PocketGeiger
-
Yaguchi Denshi Kogyo Co., Ltd.
Pocket Geiger is a smartphone-connected radiation detector. We have three product types on PocketGeiger series to support various devices you have.; iOS, USB and Embedded ( for ARDUINO, PIC, Edison).
-
Product
Nuclear Radiation Detector
-
Henan Bosean Electronic CO.,Ltd.
A small and medium-high range radiation dose alarm instrument, with the main function of monitoring X-ray, γ-ray and β-ray. We provide nuclear radiation detector OEM/ODM service.
-
Product
Solar Radiation (Sunshine) Test
-
This test determines the effects of direct solar radiation on components and material. The heating effects of solar radiation differ from those of high air temperature in that the amount of heat absorbed depends on the roughness and color of the surface on which the radiation is incident and the angle of incidence to the sun. Variations in the intensity of solar radiation over the surface of the component, may cause components to expand or contract at different rates, which can lead to severe stresses and loss of structural integrity. In addition, degradation due to photo-chemical changes can occur such as fading of color, deterioration of natural and synthetic elastomers and polymers. The test items that are subjected to solar radiation testing are those that are exposed to solar radiation during its life cycle, in the open, in warm climates.
-
Product
Space Radiation Tolerant 4GB DDR4
-
This 4GB Radiation Tolerant DDR4 Memory Multi-Chip Package (MCP) is a Ultra High Density Memory Solution, targeting Space Embedded Systems & Applications.
-
Product
Reference Radiators / Comb Generators
-
The Spectrum Generator is a family member of the Schwarzbeck pulse generators, which are used as pulsestandard world wide. Whilst the latter one uses a bounce free relay contact to discharge a coaxial lineto the load resistor, it uses a special avalanche transistor instead of the relay contact.
-
Product
600MHz To 4GHz Radiation Measurement System
RMS-0640
-
The MegiQ Radiation Measurement System (RMS) is a compact test system that performs 3-axis radiation pattern measurement in non-anechoic spaces.
-
Product
Human Radiation Spectrometers
-
Human radiation spectrometer is designed for express control and measurement of the activity of 137 Cs and 134 Cs gamma-emitting radionuclides in the human body, as well as for assessing the internal radiation dose (“sitting in a chair” geometry).
-
Product
RF Conducted Immunity Test System
RFCI61000-4-6
-
RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.
-
Product
Silicon Charged Particle Radiation Detectors
-
ORTEC introduced the first silicon surface barrier detectors for charged particle spectroscopy in the early 1960’s. Since then, ORTEC has expanded the product line with more than ten different options to choose from.





























