Current Clamps
measure AC or AC-DC amperage without contacting conductors.
-
Product
AC/DC Split Core Current Sensor CT1000S
-
This AC/DC split core current sensor is designed for measuring large DC and AC currents in applications such as electric vehicles, renewable energy systems, inverters, and motors. It facilitates high-current measurements by clamping around existing current connections. With its voltage output, this sensor is compatible with power analyzers (WT series and PX8000) and waveform measurement instruments (ScopeCorders and DLM series), making it a versatile tool for various high-current measurements.
-
Product
SpikeSafe DC / Continuous Pulsed Current Sources
-
The Vektrex SpikeSafe™ DC / Continuous Pulse (DCP) Current Sources provide reliable DC or pulsed drive for LED or laser diode reliability testing, IESNA LM-80 maintenance testing, and other test applications requiring DC or continuous pulse current. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, accurate pulsing over long output cables, precise current, precision pulsing for improved measurement repeatability, and high power density — typically 6.4kW-8kW.
-
Product
Integrated Current Sensors
HMSR series
-
The HMSR is a new generation of high insulated Integrated Current Sensor from LEM. These product family provides a robust, compact and very accurate solution for measuring DC and AC currents in all highly demanding, switching power applications for commercial, industrial. HMSR is a micro core based open loop sensor with a reinforced insulation and overcurrent detections (user configurable and factory set). These features make the device suitable for high voltage applications requiring high precision and strong immunity against external field. The primary conductor (pins 1 and 8) has very low electrical resistance and dedicated pads d
-
Product
Split type Pulse Current Sensor
CTF-03
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Suitable for the operation and cable continuity check of the equipment by pulse current detection method. Wide AC current range from 0.1mA to 8A. Ultra compact and light weight. High sensitivity and least affection from external magnetic field.
-
Product
Through Hole Type AC Current Sensor
CT-13K
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*For AC current and power measurements.*High accuracy and compact size.*Measuring range:AC 1A~50A.
-
Product
Current Measurements of PWM or Inverter, AC/DC 5~100A, φ16mm
CTF-100DC
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 5~100A*For current measurements for PWM or inverter
-
Product
Current Transformers Test Set
-
Supreme Instrument Laboratories
The basic unit is sensitive magnetic comparator and also it incorporates electronic null detector to facilitate the balance. The reference Current 5A. or IA. obtained from Standard Current Transformer and in comparison to that the vector length and phase displacement is measured. The ratio error in percentage and phase displacement in minutes are directly compared and indicated on dials.
-
Product
3-Phase Current Meter With 3 X 75A Clamp-On CT
EVA-2210
-
LoRaWAN® wireless connectivity3 x 75A Clamp-On CTBattery life up till 3.5 years@25 °C, 60 mins interval settingEasy to deploy and maintain
-
Product
Mini Digital Clamp Tester (CE)
M-2020
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*40mmφCT window and ultra compact size.*Low cost and multi-function clamp tester.*Data hold function and auto power off.*Conform to IEC safety requirements.
-
Product
16 SE Or 8 Diff. Input Channels, 4 Analog Current Output Channels, PCI Express
APCIE-3121-16-4C
-
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
Product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-45NK
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement*DC leakage current measurement*Least affection from the magnetization of core and temperature fluctuation*Convenient +24V single polarity power supply
-
Product
Primary & Secondary Current Injection Testing Sets
-
Primary current injection kits are used to test and commission Circuit Breakers, Bus Bars, CTs, Relays, MCCs, PCCs etc. These are also used for high current injection and simultaneously measuring voltage drops and hot spots in bus-bar joints, Circuit Breaker Contacts etc.
-
Product
Metra ACDC Clamp
300A
-
Metra Clamp 1000A /300A measures important electrical parameters like AC Current, AC Voltage, DC Voltage. It also features Capacitance, Ohm & Continuity, frequency, Duty cycle and temperature meas-urement.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 12-Channel, 1-Pole
40-514-107
-
The 40-514-107 (PXI) and 42-514-107 (PXIe) are low density multiplexers in dual 12-channel, 1-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Self Testing Clamps with Visual Indication
Bond-Rite REMOTE
-
As an alternative to the standard Bond-Rite, a ?remote? version is also available. In this configuration, the Intrinsically Safe monitoring electronics, flashing green LED and battery power supply are housed inside a tough, corrosion resistant stainless steel enclosure, designed for wall mounting. An insulated stowage point, for the safe return of the clamp when not in use, is included.
-
Product
AC Digital Clamp Meter
SK-7601
-
Up to 300A AC., Conductor dia. : Φ27mm max., Compact size clamp neatly fit in your hand., Twist-resistant beaked clamp head., Auto power off., Display hold.
-
Product
Resistive Current Tester
-
Weshine Electric Manufacturing Co., Ltd
Long Distance Digital Zinc Oxide Arrester Resistive Current Safety Testing Set
-
Product
PXI/PXIe Wide Current Range Matrix Module, 6x4, 2-Pole, X & Y Loop-thru
42-514-002
-
The 40-514-002 (PXI) and 42-514-002 (PXIe) are low density matrices in 6x4 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
DC/AC Earth Leakage Current Measurement
FDAZCT-11L-0.4
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Bipolar ±15V Power Supply.*Output ±5V at primary nominal current.*Applicable Frequency DC-18kHz.*Inside Diameter:φ11mm
-
Product
Auxiliary Current Transformers
-
Osborne Auxiliary Current Transformers are often used to reduce system currents to lower values appropriate for instrumentation and/or protection circuits. The Aux CT’s are designed for specific current ratios and burden impedance with a known transformation error. Osborne’s units are built for high performance and longevity in the most demanding environments.
-
Product
Clamp type AC Current Sensor/for Low Leakage Current Measurements(ZCT Series)
ZCT-22F
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Best sensor for leakage current measurements*Ultra compact size*AC 1mA~100A
-
Product
Lightning Current Generator
-
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.
-
Product
Leakage Clamp Meters
3920 CL
-
Standard Electric Works Co., Ltd
● Designed for testing AC current and AC voltage. ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Low battery indication.
-
Product
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 Meter Cable
CP150-6M
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.
72-7226 CAL
-
The 72-7226 CAL from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.
-
Product
AC/DC Clamp Meter
3810 CL
-
Standard Electric Works Co., Ltd
● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
-
Product
Voltage And Current Amplifier
KINGSINE KA30 / KA60
-
KINGSINE Electric Automation Co., Ltd.
KINGSINE's KA30 / KA60 voltage and current amplifier is high accuracy, high power, Panel-mounted type real time simulation power amplifier with four-phase voltage and three-phase current.
-
Product
MCB Tripping Current Characteristic Test Bench
-
The SCR Elektroniks 12 station MCB Tripping Characteristics Test Bench is optimally designed to verify the Tripping Characteristic of MCBs as per clause 9.10.1 of IEC 60898 (Also mentioned in Indian Standards IS 8828). The bench essentially comprises of Servo Controlled mechanism to set and maintain desired current (against incoming mains fluctuation) and a Micro controller based master controller unit plus timer, which governs the entire sequence of operation making it a stand-alone system once the user connects the MCB and configures the test parameters.
-
Product
Integrated Two-Stage Current Sensors
-
If ultra-low noise performance is required, our integrated two stage devices are the number one choice. With input inductances from 24 nH to 1.8 µH and a flux-noise level as low as 0.8 µPhi0/sqrt(Hz) an energy resolution of about 45 h is attained. The devices consist of a 16 SQUID series array as amplifier stage and a single front-end SQUID.