Product
Test Port Adapter Set, 3.5 Mm (Test Port) To Type-N
85130C
-
The Keysight 85130C test port adapter is designed to protect the test set port when it would be directly connected to the device under test. These adapters have a special rugged female connector designed for connecting to the network analyzer test port. This special connector will not mate with a standard male connector, but converts the rugged test set port to a connection that can be mated with the device under test. The set contains a 3.5 mm to type-N male adapter and a 3.5 mm to type-N female adapter. The frequency range for these adapters is dc to 18 GHz with a return loss of 28 dB or better.
-
Product
PXI-2549, 2.7 GHz, 50 Ω, Dual-Terminated SPDT PXI RF Relay Module
778572-49
Relay
2.7 GHz, 50 Ω, Dual-Terminated SPDT PXI RF Relay Module - The PXI‑2549 is a general-purpose single‑pole double‑throw (SPDT) switch module. You can use it to add flexibility to your switch network or to maintain uniform signal paths across multiple channels when building high‑channel‑count multiplexers. The PXI‑2549 termination resistors minimize reflections on open channels and protect your source or device under test from damage. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use its onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
Regenerative Power System, 500 V, 20 A, 5 kW, 200/208 VAC
RP7951A
DC Power Supply
The RP7951A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test. The regenerative capability enables the energy normally consumed to be returned to the grid cleanly, saving costs associated with energy consumption and cooling.
-
Product
Regenerative Power System, 20 V, ±800 A, 10 KW, 200/208 VAC
RP7933A
DC Power Supply
The Keysight RP7933A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test.
-
Product
Power/Voltage Rail Probe. 4 GHz Bandwidth, 1.2x Attenuation, +/-30V Offset, +/-800mV
RP4030
-
The Teledyne LeCroy RP4030 Power Rail Probe meets the specific requirements of those who need to acquire a low-voltage DC signal as part of a:-Comprehensive power integrity, digital power management IC (PMIC), voltage regulator module (VMR), point-of-load (POL) switching regulator, or low-dropout regulator testing- Complete embedded power management system that includes PMICs, VRMs, POLs, and LDOsThe RP4030 will faithfully acquire a low-impedance, low-voltage DC power/voltage rail signal without unduly loading the device under test (DUT), while providing high offset to allow DC power/voltage rail signal display on an oscilloscope with high gain.
-
Product
PXI Power & Sense Multiplexer, 2-Pole, 18-Channel
40-658A-002
Multiplexer Module
The 40-658-002 is a PXI multiplexer combining a 2-pole 18-way power distribution MUX with a second lower power 2-pole 18-way MUX in a convenient single slot PXI module. It is ideal for power distribution where power and sense signals are required to be connected to an array of devices under test.
-
Product
RF Shielded Test Enclosure, Largest Rack Mountable Enclosure
JRE 1724
-
Originally designed for testing wide screen laptops, the rack-mountable JRE1724 is ideal for large wireless devices such as; Mesh Network AP's, Cellular/LTE/4G Base Stations, and other large RF devices. Featuring rugged welded aluminum construction, you can be assured of its tight RF shielding effectiveness. Long life door gasket material along with double edge engagement not only provides solid RF shielding, but smooth trouble free operation over its lifespan. Internal struts keep the lid open for easy internal access when connecting the device under test.
-
Product
Mobile Communications DC Sources (45 W, 100 W):
663xx Series
-
Use this family of specialized DC power sources to test your digital wireless appliances. All models offer DC sourcing, current sinking, fast transient response, GPIB, and measurement capabilities to help you with the unique challenges of simulating batteries and battery packs and measuring the current drawn by your device under test.
-
Product
1kV, 120 MHz High Voltage Differential Probe Without Tip Accessories and with Auto Zero Disconnect
HVD3106A-NOACC
-
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
Product
PXIe-4112, 2-Channel, 60 V, 1 A PXI Programmable Power Supply
782857-01
Programmable Power Supply
The PXIe‑4112 is a programmable DC power supply with isolated outputs. It helps simplify the task of designing automated test systems for a wide range of applications—from aerospace and defense to automotive and component test—by eliminating the need to mix multiple instrumentation form factors in a given test rack. It also has standard output disconnect functionality that allows isolation from the device under test (DUT) when not in use, and remote sense to correct for losses in system wiring.
-
Product
PXIe-4143, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit
782431-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA Precision PXI Source Measure Unit - The PXIe-4143 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4143 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4143 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
RF / MW switch
-
The RF / MW switch includes a variety of RF and microwave switch modules - RF multiplexers, which are available for use in the 34980A multifunction switch / measurement unit, providing broadband switching from DC to 20GHz . Use these modules to route test signals between your device under test and a signal source, oscilloscope, spectrum analyzer, or other instrument. The switch / attenuator driver module also controls the external switches and attenuators of the 34980A.
-
Product
Frequency Response Analyzer
-
A frequency response analyzer measures the gain and phase response characteristics with respect to frequency of the device or system under test, by applying a frequency swept sine wave to it and examining its response signal.Featured wide dynamic range realizes high precise measurement, and also ultra low frequency measurement.
-
Product
PXIe-4154, 2-Channel, 8 V, 3 A PXI Programmable Power Supply
781155-01
Programmable Power Supply
2-Channel, 8 V, ±3 A PXI Programmable Power Supply—The PXIe‑4154 is a specialized programmable power supply for battery simulation. It is designed to simulate a lithium‑ion battery cell’s transient speed, output resistance, and 2‑quadrant operation (source/sink). Critical to many RF and wireless applications, the simulator’s fast transient response time allows it to rapidly respond to changes in load current with minimal voltage dip, which makes the PXIe‑4154 ideal for powering devices under test (DUTs) such as RF power amplifiers, cellular handsets, and a variety of other mobile devices. To model the behavior of a battery more accurately, you can use the onboard programmable output resistance to simulate a battery’s internal resistance. For quiescent and standby current measurements, the PXIe‑4154 features integrated current measurement.
-
Product
Pulse Function Arbitrary Noise Generator
81160A
Arbitrary Waveform Generator
Generation of 330-MHz pulses and 500-MHz function/arbitrary waveforms with a 2.5-GSa/s sample rate and 14-bit vertical resolution; Selectable crest factors for white Gaussian noise lets engineers determine how much distortion to apply to a device during stress testing to meet various serial bus standards; Glitch-free timing parameter changes allow engineers to change the frequency without drop-outs or glitches and enable continuous operation without rebooting or resetting the device under test; and Arbitrary bit patterns show capacitive load of the channels using simple pattern settings. Complex measurement setups are no longer necessary to test designs to their limits. Pulses 330 MHz, 500 MHz sine waves, 660 Mbit pattern
-
Product
PXI 18 Channel Data Comms MUX, 96-pin SCSI
40-735-902
Multiplexer Module
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
Product
PXIe-2748, 3 GHz, 16x1 PXI RF Multiplexer Switch Module
780587-48
Multiplexer Module
PXIe, 3 GHz, 16x1 PXI RF Multiplexer Switch Module—The PXIe‑2748 is a PXI RF multiplexer switch module that is ideal for switching RF signals up to 3 GHz in production test applications. The high channel count of the PXIe‑2748 makes it well-suited for test systems that require switching a large number of RF signals, such as switching several devices under test to a single channel on the RF analyzer. It also features onboard relay counting for relay monitoring.
-
Product
Regenerative Power System, 80 V, ±250 A, 10 KW, 200/208 VAC
RP7935A
DC Power Supply
The Keysight RP7935A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test.
-
Product
Nonlinear Component Characterization 10 MHz - 50 GHz (Export Control)
S94511B
-
The S94511B Nonlinear Component Characterization provides strong insight into the nonlinear behavior of your device under test (DUT).
-
Product
12-Ch 10A-250VAC RCV Power Distribution Unit
YAVAR438
Switch Module
- Hardware controlled Enable Input- 12 Power relays up to 10A 250VAC/DC and 300W or 2.700VA switching power- 12 10-mOhm shunt resistors.- 6 Switched 2-Pole sense channels- Single phase isolated or 3-Phases non-isolated switching capabilities, to or from the device under test (power or load)- VPC TriPaddle 96 pins connector.- NI LabView & TestStand driver.- .NET, C/C++, VB driver.- Soft Front panel for direct interface.- CAN Control or Ethernet (with Ethernet to CAN Gateway).- Self-test module available.- Form A
-
Product
3-Axis Motion Simulators
-
When a device under test needs to be stimulated with simultaneous movements around three axes, then a product from the ACUTRONIC three-axis motion simulator range is the right choice. Independent motion simulation in three axes makes them very versatile: they are used as Inertial Guidance Test Systems (IGTS), for HardWare-In-the-Loop (HWIL) testing, for the test of optronic pointing devices, and many more applications.
-
Product
BERT Measurement Solutions
-
Bit error rate testers (BERTs) are usually the initial step for communications testing. These instruments generate digital test patterns, typically pseudorandom binary sequences (PRBSs), that drive devices under test (DUTs). Following the transmission of the signal through the link, the receiver in the BERT captures the signal. This setup can be used for multiple testing purposes, such as to evaluate the performance of a transmitter, a receiver, or an optical link.
-
Product
2 GHz Dual 1:4 RF Mux, 50 Ohm Module for 34970A/34972A
34905A
Multiplexer Module
The Keysight 34905A RF multiplexer module for the 34970A/34972A Data Acquisition/Switch Unit offers broadband switching capabilities for high-frequency and pulsed signals. Use it to route test signals between your device under test and your signal generator, oscilloscope, spectrum analyzer, or other instrumentation.
-
Product
4x8 2 Wire USB Modular Switch Matrix
U2751A
Switch Module
The U2751A USB Modular Switch Matrix offers a flexible connection path between the device under test and the test equipment, thus allowing different instruments to be connected to multiple points on the device under test at the same time. This instrument is able to support measurements at a high bandwidth of up to 45MHz. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity
-
Product
Artificial Power Supply Network
KH3760
-
Beijing KeHuan Century EMC Technology Co,.LTD
The artificial power supply network (also called the power supply impedance stabilization network) should be able to provide a stable impedance to the device under test in the radio frequency range, isolate the device under test from high-frequency interference on the power grid, and then couple the interference voltage to the receiver.
-
Product
Kelvin Test Contactor/Probe Head
Gemini
-
At 3.22 mm test height, the Gemini™ Kelvin test contactor is an excellent all-around spring probe with low inductance, high bandwidth, and excellent current-carrying capacity. The device under test (DUT) side tip design accurately maintains its 100 µm spacing for the life of the probe. Customers report typical probe life of 500 k to 800 k package insertions, or over 2M touchdowns at wafer-level test. The offset tip allows manageable board layout with a board-side spacing of 0.4 mm.Gemini Kelvin probes and contactors provide a first-rate solution that effortlessly makes reliable, true Kelvin contact for high-volume final test of both singulated packages and wafer-level devices. Gemini Kelvin is an ideal solution for devices such as power controllers, A-D and D-A converters, power amplifiers and audio and video circuits.
-
Product
Artificial Power Supply Network
KH3763
-
Beijing KeHuan Century EMC Technology Co,.LTD
The artificial power supply network (also called the power supply impedance stabilization network) should be able to provide a stable impedance to the device under test in the radio frequency range, isolate the device under test from high-frequency interference on the power grid, and then couple the interference voltage to the receiver.
-
Product
Accessory EFT/Burst generators IEC 61000-4-4
-
The field sources and the burst transformer are used to harden the device under test. They are powered by an EFT/burst generator.
-
Product
Regenerative Power System, 950 V, 20 A, 10 kW, 400/480 VAC
RP7963A
DC Power Supply
The RP7963A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test. The regenerative capability enables the energy normally consumed to be returned to the grid cleanly, saving costs associated with energy consumption and cooling.
-
Product
Qualification Tester
LQ402
-
Computer Gesteuerte Systeme GmbH
The qualification tester LQ402 is designed to support up to 6 DUTs (Device under Test), for which the loads are installed in separate load boxes. The system consists out of 2 cabinets. One is for the electronic components with the primary measurement devices and the other one holds the 6 load boxes.