product
Charge Sensitive Preamplifier-Discriminator
A101
Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.
-
product
Digital Multi Channel Analyzer
DT5770
The DT5770 is a compact portable 16k Digital MCA for Gamma Spectroscopy, integrating analog front-end with programmable gain and possible AC coupling. It is ideally suited for high energy resolution semiconductor detectors, like HPGe and Silicon, connected to a Charge Sensitive Preamplifier (CSP). The unit can also properly operate directly connected to a PMT with inorganic scintillators (e.g. Nal or Csl scintillators), provided exponential pulse shape and decay time above 200 ns.
-
product
Pre-Amplifiers
MPR, MDA series
MPR, MDR series provides low noise, high gain and wideband to improve dynamic range for emission testing. We also offer customized model for variable requirments.. Example 30M-1000MHz with band-pass filter Amprifier unit for connecting antenna directly
-
product
External Pre-amplifiers
Although all Spectrum A/D cards have a very powerful input section with a highly configurable input amplifier and a variety of input ranges it is sometimes necessary to have additional external amplifiers if the signal to acquire has an extremely low level. Spectrum offers a range of perfectly matching external amplifiers to cover such cases. These powerful amplifiers have been rated using the Spectrum cards and offer best performance together with high amplification rates.The amplifiers are simply connected between the signal source and the Spectrum A/D card input and can be manually switched between different settings using small lever keys. All amplifiers allow the offset compensation by using an adjustable screw.
-
product
Microphone Preamplifier
HT426E01
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
product
Microphone Preamplifier
426E01
Nominal Microphone Diameter: 1/2 Gain -0.05 dBFrequency Response (0.1 dB) (re 1 kHz)6.3 to 125000 HzFrequency Response (-3 dB) (re1 kHz) Phase Linearity (<1 )32 to 20000 Electrical Noise (A-weight)<2.8 V<2.8 V[1] Output Slew Rate 2 V/S[2]
-
product
Preamplifiers
LNA Series
Low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity of virtually all spectrum analyzers and other RF measuring instruments. All measuring instruments have a 'noise figure', which is a measure of how good the instrument is at measuring low level signals, the lower this figure, the better, although the lowest signal level will still be governed by the measurement bandwidth. A typical spectrum analyzer may have a noise figure of 20 dB or more, whereas a typical receiver may have a noise figure of 10 dB. The preamplifier has a noise figure of typically 4 dB, significantly enhancing the low level performance of such instruments, enabling signals that were previously masked by noise to be seen.
-
product
Preamplifiers
The primary function of a preamplifier is to extract the signal from the detector without significantly degrading the intrinsic signal-to noise ratio. Three basic types of preamplifiers are available: the current-sensitive preamplifier, the parasitic-capacitance preamplifier, and the charge-sensitive preamplifier. ORTEC manufactures a preamplifier to fit your detector, your application, and your budget.
-
product
Transformer Preamplifier
SR554
Stanford Research Systems, Inc.
The SR554 is a low-noise, transformer-coupled preamplifier optimized for source impedances between 0.05 Ω and 1 kΩ. With an input noise of only 0.1 nV/√Hz, the SR554 can be used in a wide range of low-noise applications.
-
product
Microphone Preamplifier
426A30
1/2-inch preamplifier with 7-pin LEMO connector (for externally polarized microphones)
-
product
Lock-In Voltage Preamplifier
SR550
Stanford Research Systems, Inc.
The SR550 Voltage Preamplifier is designed to work with any SRS lock-in amplifier. Preamplifiers provide gain close to the experimental detector, before the signal-to-noise ratio is permanently degraded by cable capacitance and pickup
-
product
Spectral Sensitivity Measurement
It is a device which measures the spectral sensitivity characteristics and quantum efficiency of various solar cells by irradiating solar cells with monochromatic light of constant energy and constant photon without wavelength dependence. We are constantly monitoring irradiation light quantity with our real real time light quantity monitor control system and are not influenced by fluctuation of light source, so it is a well-established control system with excellent measurement stability and measurement reproducibility.
-
product
Sensitivity Testing
Response Dynamics Vibration Engineering, Inc.
Sensitivity testing involves making predictions of system response to environmental disturbance. The significance and importance of the system sensitivity estimates is very often overlooked. This gets companies in trouble and is one of the top reasons why we are called upon to provide timely solutions. Most teams are focused on getting their product to work and get it out the door. An engineering team will often not know how to quantify what to expect in the customer environment and how to test for those expected disturbances. We design hundreds of sensitivity tests and can explain the important concepts to consider in designing the tests and making the right measurements that allow for sound estimates of system response. This is an important expertise we use in our vibration, acoustic and magnetic field consulting services.
-
product
EV Charging Station
Residentual
BENEFITS OF RESIDENTIAL CHARGING: *Charge up to 7x faster than the Level 1 cordset that came with your electric vehicle. *Level 2 (240V) charging stations are more affordable than ever – starting at just $379! *Tax incentives and rebates offset purchase and installation costs, up to 100% in some areas *It’s more convenient to charge at home than using a public station. *Indoor/Outdoor rated (fully sealed NEMA 4 enclosures) *The Level 1 cordset that came with your electric vehicle can be used as a portable charging station or for a second charging station when you have company with an EV.
-
product
Dual-Mode Charge Amplifiers
Dual-mode charge amplifiers represent a versatile solution for both piezoelectric charge mode and ICP® sensors. Among the advanced features offered by models 443B01, 443B02 and 2775C are an ultra-low noise floor, sensor fault detection, overload detection, a built-in calibration reference signal, and an RS-232 port for seamless computer control. Notably, model 443B02 features a long discharge time constant selection, ideal for capturing quasi-static events lasting several seconds, a capability particularly beneficial for ballistics and ammunition testing applications. Model 2775C features AC, DC, and servo outputs.
-
product
Vibration Sensitivity Tester
Vibratron II
The Vibratron II provides a non-invasive means of measuring the sensitivity to vibration of large nerve fibers of a patient's fingers and toes. Reliable quantitative measurements are achieved with a test that takes only minutes to administer. A two-alternative forced choice procedure is used to determine the degree of sensitivity for comparison to normals.
-
product
350 MHz Preamplifier
SIM914
Stanford Research Systems, Inc.
The SIM914 350 MHz Preamplifier contains two wide-bandwidth, DC-coupled amplifiers, each with a gain of 5 (14 dB). Its fast rise time, low noise and excellent DC accuracy make it an ideal instrument for amplifying signals like those from photomultiplier tubes and photodiodes.
-
product
20-50,000 Hz Charge Amplifier
203G8
The Trig-Tek™ 203G8 accepts pickupswith sensitivities varying from 1 to 110pC/g. It has three simultaneous outputs:Acceleration with a sensitivity of 100 mVrms/Pk g; Velocity with a sensitivity of 534mVrms/Pk/ips; and Displacement with asensitivity of 100 mV/mil DA.
-
product
DC/DC With UPS And Charge Controller
PCM-PS402-512
WINSYSTEMS’ PCM-PS402-512 is a wide input range, triple output PC104 DC/DC converter with a built-in battery charger and uninterruptable power supply (UPS) controller. Designed for harsh environments, the power supply operates from -40° to +85°C without a fan or heatsink making it ideal for industrial applications.
-
product
High Sensitive Radiometers for Plasma Diagnostics
ELVA-1 radiometers for plasma diagnostic are worldwide known product. The custom designed ECE radiometers have been installed at lots of Tokamaks
-
product
Charge System Safety
Renesas' charging system safety circuits are optimized to provide a redundant safety protection to an Li-ion battery charging system by monitoring input voltage, battery voltage and charge current.
-
product
High Sensitivity ICP® Accelerometers
High sensitivity ICP® accelerometers are specifically designed to enable the detection of ultra-low-level, low-frequency vibrations associated with very large structures, foundations, and earth tremors. These sensors typically possess exceptional measurement resolution as the result of its comparatively larger size, which furnishes a stronger output signal and a lower noise floor. All units are hermetically sealed in a titanium or stainless steel housing. Models that include a 2-pin, military style connector provide the added benefit of being electrically case isolated for superior RF and EMI protection.
-
product
Time Sensitive Networking Evaluation-Kit
The evaluation kit offers developers the possibility to test and evaluate Ethernet TSN for their own applications. It consists of either a Smartzync board (Xilinx) or a Netleap board (Intel/Altera) with an optionally implemented IPMS TSN-IP core for endpoint applications (TSN-EP), switched endpoint applications (TSN-SE) or switch applications (TSN- SW). Linux drivers with application examples, as well as RTOS test applications and TSN network configuration examples are also available.
-
product
Charge Amplfiers
Trik-TekTM Line
Astronics offers the Trik-TekTM line of charge amplifiers, available in a variety of configurations for your application.
-
product
DC to 350 MHz Preamplifier
SR240A
Stanford Research Systems, Inc.
The model SR240A 350 MHz Preamplifier is a 4-channel, DC-coupled instrument with a gain of 5 per channel. The amplifiers can be used independently or cascaded to provide gains of 5, 25, 125 or 625.
-
product
Test Accelerometer Sensitivity And Noise Test
Accelerometer Test Unit
*Quick and Accurate Accelerometer Test*Battery operation*All tests use 32-bit resolution A to D Converter*All data downloaded to PC via Ethernet link*Records all data to a flexible easy to use database*Records time and date of tests
-
product
EV& Charging Pile Test Set
DC Testing
With the development of Electric Vehicles in the world, more and more charging piles have been installed in different places. Due to the different understanding of the standards among EV manufacturers and charging piles suppliers, there may be hidden danger during the charging process.
-
product
Charge Amplifier
CH-1200A
CH-1200A is a high-performance charge amplifier to convert charge signal to voltage signal. Built-in integration function allows optimization of the signal which is input to the vibration data analyzer connected.Changing into a multi-channel amplifier is easy by connecting multiple units.
-
product
Repeated Charge Discharge Test Set
The IS 13341 : 1992 has laid down the requirements for Ageing Test, Self-Healing Test and Destruction Test on Shunt Capacitors of the self healing type for AC Power Systems. The Ageing Test is to be performed at a specified voltage of 1.25 times the rated voltage for 750 hours. The test is to be followed with a repeated discharge cycle test which involves charging of the capacitor to a DC voltage and discharge of the same through an Inductance. Sivananda Electronics has developed this equipment for the benefit of capacitor manufacturers, for the first time in India.
-
product
Low-Noise Voltage Preamplifier
SR560
Stanford Research Systems, Inc.
The SR560 is a high-performance, low-noise preamplifier that is ideal for a wide variety of applications including low-temperature measurements, optical detection, and audio engineering