Frequency Calibrators
-
Product
130/180 MS/s Dual Channel PXI Express Digitizer for Frequencies up to 175 MHz
PXIe-1803
Digitizer
This 130/180 MS/s Dual Channel PXI Express digitizer provides the best speed and performance available for input frequencies up to 175 MHz.With exceptional signal integrity, high density and modularity, and channel synchronization options, this new digitizer provides massive functionality in a compact form factor.Key features include:Dual 14/16-bit digitizer configurable as separate or fully synchronized channelsWaveform bandwidths of 65-175 MHz (typical)64M words of waveform memory per channelExternal clock input for synchronization up to 180 MHz250 μV Measurement AccuracyNoise Floor and RelativeAccuracy as Precise as 0.006%
-
Product
Electromagnetic Resonance High Frequency Fatigue Testing Machine
PLG Series
-
Jinan Testing Equipment IE Corporation
The series of electromagnetic resonance fatigue testing machines are used for fatigue tests of metal materials and components under tension, compression or reversal loads. If relevant grips are provided, three-point bending test, four-point and circle test, gear wheat, bolt, connecting rod, roller chain, crackle expanding test can be available. The series of electromagnetic resonance fatigue testing machines feature an optimized design and a rational structure. The automatic controlled system adopts an advanced and wide-pulse-control system and a new-type of power amplifier to improve the reliability of the electric system. The electromagnetic resonance fatigue testing system is with high efficiency, easy and non-stop shake, low energy consuming, accurate control, and small fluctuation.
-
Product
Backflow Test Kit Repair Calibration & Certification
-
Meeting Water Safety regulations and standards has become a primary concern for all industries. Most municipal and state regulators demand that Backflow Prevention Testing be carried out no less than once per year and that testing devices be calibrated and if required, certified regularly.
-
Product
Portable Frequency Meter
SonicSniffer
-
SonicSniffer is a portable frequency meter for preventive maintenance of ultrasonic transducers and power ultrasonic stacks, primarily in cutting and ultrasonic welding fields. The SonicSniffer determines the work frequency of the ultrasonic stack analyzing the sound emitted by the equipment during operation. See in the back side of this sheet how to use this information.
-
Product
NIST Calibration for D610-A
D610-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Low Frequency RF Broadband Power Sources
-
Class A has RF power source, ideal for Industrial /Scientific / Medical applications. Class AS is a robust source of RF power for ultrasonic, laser modulation, RFI/EMI, plasma generation, general laboratory and industrial applications.
-
Product
Rubidium/GPS Frequency Standard
PXIe-3352
-
The Astronics Test Systems PXIe-3352 frequency standard module sets a new standard for high density functionality in a PXI module by combining a Rubidium oscillator with a GPS receiver into a single, compact instrument.
-
Product
8 Channel 1GHz High Frequency for SBDT Relay Module
DP-cPCI-4158
-
DP-cPCI-4158 is a 8 channel high frequency SPDT relay module. It provides for 1000V DC isolation between channels. This module is constructed using SPDT relays.
-
Product
Open-Short-Load RF calibration kits
-
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
Product
Digital/Analog Frequency Response Analyzer
8800 Series
-
The analyzer utilizes a digital “Sync” signal to provide synchronization between analog and digital hardware. The Model 8800 performs simultaneous analysis on both analog input channels and digital target processor, reliably capturing all data. Versatile by design, the Model 8800 digital interface can be disabled, via software, to use the analyzer in a standard 2-channel, analog-only configuration.
-
Product
Medical Device Calibration
-
Trescal provides full Medical Device Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Medical Device Calibration services can be delivered at your site or at our lab. Accreditations for our medical device calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Electrical Calibrators
-
An electrical calibrator, or dc calibrator from Fluke Calibration includes many innovative and multi-functional solutions to help laboratories operate efficiently, increase throughput, and comply with today’s quality standards. Versatile models and options provide a wide range of possibilities to match a variety of workloads and budgets. Electrical calibrators include: Multi-product calibrators; multifunction calibrators; oscilloscope calibrators; power calibrators; pressure/temperature calibrators.
-
Product
Mercury Argon Calibration Source
HG-1
-
The compact, low-cost HG-1 Mercury Argon Calibration Source is a spectral wavelength calibration source for UV-VIS-Shortwave NIR spectrophotometric systems.
-
Product
Sound Level Meters and Calibration
-
PeakTech Prüf- und Messtechnik GmbH
This digital sound level meter is designed for noise projects, quality control and all kinds of measurements of ambient sound, as well as for sound measurement in factories, schools, offices, in traffic , Household and much more used.
-
Product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
-
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
Product
Universal Solution for Model-based Calibration Software
INCA
-
INCA tools are used for ECU development and test as well as for validation and calibration of electronically controlled systems in the vehicle, on the test bench, or in a virtual environment on the PC. The tools are used worldwide in over 20,000 installations in development and production projects.
-
Product
Optical & RF Test Equipment Repair and Calibration
-
Custom Calibration Solutions, LLC
We are the only commercial repair lab in the country capable of fixing major problems with optical test equipment including OSA's, Tunable Lasers, Attenuators and Optical Wavelength meters.
-
Product
4-Port 9 GHz Analyzer, Frequency Extension Compatible
C4409
-
C4409 Vector Network Analyzer delivers industry-leading dynamic range and sweep speed, with all the features engineers have come to expect included standard in our software. This VNA is frequency extender compatible and is the anchor network analyzer for the CobaltFx frequency extender system.
-
Product
CableEye Tester Calibration Verification Board | Cable & Harness Tester
CB50
-
Populated with precision resistors, it allows users to determine empirically whether the tester requires calibration. The CB50 may be used on all CableEye models. The CB50 is intended for periodic verification of tester calibration. To ensure that resistance measurements remain accurate, CAMI recommends yearly calibration. However, depending on environmental conditions and usage, testers may need calibrating more or less frequently.
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Frequency Meters
-
Passive frequency meters are intended for moderate (±0.05%) accuracy applications in microwave measuring setups. Keysight's meters feature broadband coupling loops that provide flat power transmission off-frequency.
-
Product
Air Pollution Multigas Calibrator
APMC-370
-
Dilution of gases with high accuracy and precision requires high quality MFC’s, especially for high dilution ratios and ranges. Consequently HORIBA’s APMC-370 is equipped with digital MFC’s. These MFC’s are factory calibrated, optional also with a special Polynomial Calibration. HORIBA Europe‘s APMC-370 is designed to calibrate gas analyzers manually, remotely controlled or automatically. It is installed in air pollution monitoring stations for quality assurance in the laboratory and also in the production of gas analyzers.
-
Product
C Series Frequency Input Module
Input/Output Module
The C Series Frequency Input Module is designed to acquire isolated frequency inputs from magnetic pickup sensors, variable reluctance sensors, Hall effect sensors, and other transducers with a frequency output. Additionally, the C Series Frequency Input Module provides isolation, configurable thresholds, selectable filtering, and embedded counter measurement logic. These measurements can be synchronized with other frequency, analog, digital, and counter measurements in a single acquisition.
-
Product
Multifunction Field Calibrator & Communicator
MC6-Ex
-
The MC6-Ex is an intrinsically safe field calibrator and communicator. It is ATEX and IECEx certified and can be used in all hazardous zones / divisions. The MC6-Ex includes a field communicator for HART, FOUNDATION Fieldbus and Profibus protocols. Each calibrator is delivered with a traceable, accredited calibration certificate as a standard. t is a documenting, multifunction calibrator and communicator that offers calibration capabilities for pressure, temperature and various electrical signals.
-
Product
Infrared Calibration
-
Optical pyrometers can be calibrated from 800 to 2300C using NIST certified ribbon filament lamps and temperatures up to 3500C using a graphite arc furnace. Infrared thermometers can be calibrated from -30C to 2300C utilizing state-of-the-art blackbody sources and transfer standards.
-
Product
Frequency Family 0.01 – 250 MHz
-
A broadband amplifier that covers the 0.01-230 MHz frequency range. This amplifier utilizes Class A linear power devices that provide an excellent 3rd order intercept point, high gain, and a wide dynamic range
-
Product
Field Calibrator of Three Phase Energy Meter
SY3640
-
Hong Kong Songyang Industrial Ltd.
SY3640 three phase energy meter field calibrator is a high precious three phase energy reference meter; it uses the advanced technology and latest electronic components available in the world, and use high speed DSP as the main processor to ensure the accuracy and long time stability.
-
Product
Calibrator Process
VA70034
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Loop calibrator This Calibrator is use to measure or output 0 to 24 mA DC current loop, and 0 to 20 V DC voltage.
-
Product
Industrial Pressure Calibrator
2271A
-
The Fluke Calibration 2271A Industrial Pressure Calibrator provides a complete, automated solution for calibrating a wide variety of pressure gauges and sensors. Thanks to its modular design, it can be configured to meet different needs and budgets, and expanded to cover a broad workload. The 2271A is ideal for calibration laboratories starting out in pressure calibration because it offers wide pressure measurement capabilities in a single instrument. Everything you need for calibrating pressure is included; just connect supply pressure. And your investment will stand the test of time: as your workload grows and changes, the 2271A can grow and change too. Just add measurement modules.