Voltage Standards
-
Product
NI-9262, 1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module
785503-02
Voltage Output Module
1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module - The NI-9262 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. The NI-9262 module includes a channel-to-earth ground isolation barrier for safety and noise immunity.
-
Product
High Voltage EMC Surge Generator
TM510
-
TM510 Surge Generator is mainly used for testing power cable high-resistance and arc-over fault whose grade range is 0-10kV, co-operating with cable fault tester and locating devices to test and locate faults. If the user choose the professional digital milli-ampere-meter, as for cable with grade range about 0- 6kV, the instrument can also be used to do DC&voltage resistance test and current leakage test after the fault is repaired. The instrument is internally equipped with voltage-rise rectifying and discharging device, has complete functions, and is also convenient and safe to be wired and operated.
-
Product
Series II Standard Mass Flow Controller
-
Our Series II mass flow controllers & meters offer outstanding value in a wide range of applications. Exceptional accuracy for flow ranges from 0.014 sccm to 1,670 slpm, all with optional multi-gas and multi-range capability for maximum flexibility
-
Product
Voltage and Continuity Testers
-
Amprobe voltage and continuity testers have built-in shakers for fast, easy troubleshooting with CAT IV 600V/CAT III 1000V input protection. To safely detect voltages up to 122kV without contact to the current carrying conductor, choose an Amprobe high-voltage tester. These intrinsically safe tools are ideal for industrial, utility, and mine applications.
-
Product
RF Voltage Probe
P-20 Series
-
The P-20A is a PASSIVE 10:1 RF VOLTAGE PROBE with a 50 Volt DC BLOCK built in. It has been designed to allow users of RF test equipment to use standard signal tracing techniques. The P-20A makes it possible to conveniently and accurately monitor or inject signals up to 3 GHz into RF circuits without significantly loading or detuning them.
-
Product
Digital Impulse Voltage Measuring System
TR-AS
-
The well-established Impulse Voltage Measuring Systems TR-AS, including the digital recorders from our own development and manufacturing, where further developed consequently and now feature improved sampling rates up to 200 MS/s in real-time with 14 Bit resolution simultaneouly in up to 16 measuring channels.
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Cables - Connector to Connector
-
The connector to connector cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Voltage Controlled GUNN Oscillators
GV-8 / GV-6
-
Voltage controlled GUNN oscillators provide optimal electronic tuning by coupling GUNN with tuning varactor. Oscillators provide low AM and FM noise, making them suitable as local oscillators or transmitters.
-
Product
Standard Test Finger
SMT-1
-
It with Protection against electric shock device. It according to IEC60335, IEC60884, IEC61032, IEC60529, IEC60065, IEC60035, IEC60950, EN60529, EN60950, GB4706, GB7000, GB9706, UL507, VDE0470, etc.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4C
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Clamping Voltage Tester
MIG0603CLV1
-
The MIG0603CLV1 is a generator for testing varistors. It has circuits with three different source impedances and up to 11 different measurement ranges. The instrument is used to perform varistor clamping voltage tests on up to 1000 V varistor types. The test impulse is a 8/20µs current waveform up to 200A which is maintained over the entire load range.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
AC Voltage Detector
-
Triplett Test Equipment & Tools
high performance AC Voltage detector with adjustable sensitivity that has a wide measurement range of 25 to 1000ACV, Dual Color Tip to indicate low/high voltage, built-in flashlight and durable overmold. The high sensitivity allows it to detect low voltage AC wiring commonly found in doorbell circuits, thermostats, control circuits, and video surveillance camera power. The Sniff-It 3 is designed for industrial applications with its impact and drop resistance in a sleek ergonomic design, and the easy to use thumb wheel helps dial-in detection range. Includes (2) AAA batteries. CAT III safety rating.
-
Product
USB Voltage Measurement Bundle
-
The USB Voltage Measurement Bundle provides a portable, USB-based sensor measurement system that helps you measure input voltage signals while providing isolation and overcurrent protection for high-voltage applications.
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF120
-
Lifasa - International Capacitors, SA
Accessories: Differential protection
-
Product
High Voltage Amplifier
HA-205
-
*2500V/uS Super High Speed Model *170Vp-p (±85V DC) *900mAp-p (±450mA DC) *Bandwidth: 3MHz / 100Vp-p *Gain (AMPL): 0~35 (10 Turn VR+SW) *Microprocess Control Protection
-
Product
Oil Breakdown Voltage Tester
DTA IL
-
Insulating oil testing with the BAUR DTA IL. The BAUR DTA Inline is a high performance and reliable oil tester for continuous testing of the breakdown strength of insulating oils during production (inline tests). The combination of extremely short switch-off times during breakdowns and the easy oil sample handling facilitate high quality statements and conclusions on the insulating oil quality.
-
Product
Xytronic Three-Phase Site Analyzing Standard
RADIAN RX-3X-A
-
The RX-3X-A Xytronic Three-Phase Site Analyzing Standard brings precision measurements, normally associated with laboratories, to the meter site at a surprisingly affordable price. How is this possible? Radian has always designed state of the art precision measurement equipment with extreme high and low operating temperatures in mind – all site analyzers are tested at -20C to +70C. Couple precision measurement with ruggedness, throw PCSuite software automation into the mix, you have the premier RX Site Analyzing solution to meet the most demanding site measurement challenges
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25HL-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4J
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3T
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Non-Contact Voltage Tester
NT-303
-
Contact - free electrical socket indication at AC voltages between 90V-240V. Clear alarm system: flashing LED with beeper alarm.. Quick and accurate detection of circuit breaks.. Includes a small screwdriver for easy batteries replacement.. Pocket pen-type design, easy to carry and store.
-
Product
Electrical Tester For Voltage
PDT35
-
Automatically Selects VAC, VDC, or Continuity TestComplies with EN 61010-1 For Use in CATIII 600 V Environments1999 Count LCD DisplayAuto Power On/OffHigh Input Impedance -- 400 kVoltage AC: Max Range 600 V, Accuracy +/- 1.5%Voltage DC: Max Range 600 V, Accuracy +/- 3.0%Continuity TestAccessories Included: Test Leads, 2 'AA' BatteriesDimensions: 8.46' H x 2.83' W x 1.44' DWeight: 8.29 oz.Sold as : Unit
-
Product
Working Standard Shunts
CSW
-
CSW shunts are rated to 100 % continuous current with no loss of accuracy. They are largely immune from connection errors common to many shunts. All CSW shunts include ISO17025 accredited calibration through full current range.
-
Product
Standard Ratio Box For Calibration
ST-105
-
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
Product
Voltage Sag Generator
SKS-1120GTB
-
Shanghai Sanki Electronic Industries Co., Ltd.
The cycle drop simulator is used to reproduce the voltage fluctuation phenomenon of commercial power supplies. Simulate the grid voltage drop and short-term interruption caused by the accident or the sudden change of the large load in the low-voltage power grid, or the grid voltage change caused by the continuous change of the load. Used to evaluate the performance of the equipment under these voltage changes.
-
Product
DC Voltage Detector
ENVIROMUX-S60VDC
-
Monitors up to two DC voltages: -60VDC ~ 0VDC or 0VDC ~ 60VDC. Connector: Screw Terminal, 5-position. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Includes Mounting Hardware. Operating temperature: 32 to 158°F (0 to 70°C). Regulatory approvals: CE, RoHS.
-
Product
Oil Immersed Transfer Standard
esi SR1030 Series
-
The esi SR1030 transfer standards consist of 12 equal steps. These steps are available in increments of 1 (SR1030-1), 10 (SR1030-10), 100 (SR1030-100), 1k (SR1030-1k), 10k (SR1030-10k) and 100k (SR1030-100k). The esi SR1030 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature. The esi SR1010 and esi SR1030 are used for the same applications and are alike in configuration. The esi SR1030 differs from the esi SR1010 in that it is specially sealed, and values below 100 k are filled with oil to improve changes due to thermal variations.