ICP Microphones
measure acoustic frequency, time and noise levels.
-
product
Microphone Preamplifier
426E01
Nominal Microphone Diameter: 1/2 Gain -0.05 dBFrequency Response (0.1 dB) (re 1 kHz)6.3 to 125000 HzFrequency Response (-3 dB) (re1 kHz) Phase Linearity (<1 )32 to 20000 Electrical Noise (A-weight)<2.8 V<2.8 V[1] Output Slew Rate 2 V/S[2]
-
product
SparkFun Analog MEMS Microphone Breakout
SPH8878LR5H-1
The SparkFun Analog MEMS Microphone Breakout makes it easy to work with the SPH8878LR5H-1 analog microphone from Knowles. This board features an OpAmp to bring the output of the microphone to a usable level, allowing you to plug directly into an ADC on a microcontroller or something like the SparkFun Spectrum Shield.
-
product
Precision Condenser Microphone
377C10
Performance:Nominal Microphone Diameter:1/4"CharacteristicPressure Open Circuit Sensitivity1.0 mV/Pa1.0 mV/PaFrequency Range (2 dB)4 to 70000 Hz4 to 70000 Hz Lower Limiting Frequency (-3 dB)0.25 to 3.0 Hz0.25 to 3.0 Hz Resonant Frequency (90 Phase Shift)65000 Hz65000 HzHumidity Coefficient of Sensitivity (0 to 100%, non-condensing)0.0012 dB/%RH0.0012 dB/%
-
product
In-line ICP® Charge Converters
In-line ICP® charge converters play a vital role in converting high impedance charge mode piezoelectric sensor signals into low impedance voltage signals, facilitating input to readout, recording, and analysis instruments. Specifically engineered for compatibility with high temperature piezoelectric sensors, these units are capable of operation in environments reaching up to 500°F (260°C). The series boasts ±2.5V or ±5.0 V output, offering a range of gain options, all packaged within a compact and durable casing. As a cost-effective alternative to laboratory charge amplifiers, in-line ICP® charge converters present an appealing choice for multi-channel applications.
-
product
Microphone Arrays
One of the most important parts of an Acoustic Camera is the microphone array. It determines the spatial distribution of the acoustic microphones and therefore measurement performance of the whole system. In order to achieve the maximum possible performance in any given application, we offer a wide variety of microphone arrays. No matter if the measurement is beamforming, intensity or holography ... we have the right microphone array. For special applications we can design and build custom made microphone arrays according to the requirements of the application.
-
product
IDevice Calibrated Measurement Microphone
IMM-6
The Dayton Audio IMM-6 is a professional-quality measurement and recording microphone that is designed to work with the entire suite of Apple “iDevices” – iPad, iPhone, and iPod. The rugged construction and compact size make it the perfect companion for audio professionals who must work on-location performing acoustic analysis, monitoring audio levels, or recording. Each IMM-6 is individually hand-calibrated using a laboratory-standard measurement microphone, for consistent, repeatable measurements that match the level of precision previously offered only by expensive stand-alone microphones.
-
product
Modern Prepolarized Precision Condenser Microphones & Preamplifiers
Modern prepolarized microphones are designed with newer technology than traditional externally polarized microphones. Prepolarized microphones have many advantages over the externally polarized models. They use ICP® power circuitry invented for sensors by PCB®. By applying a polymer coating to the top of the backplate and embedding a charge on it, expensive 200V power supplies can be eliminated and 2-20 mA constant current supplies or signal conditioners can be used as the power source.
-
product
Measurement Microphone Cartridges
G.R.A.S. Sound & Vibration A/S
Measurement microphones are available in many types covering various frequency ranges, dynamic ranges and application situations. Selecting a microphone involves a number of choices, which can be summarized as:
-
product
Phantom Powered Measurement Microphone System
7052PH
The 7052PH Type 1.5TM phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Type 1.5TM - a superior Type 2. Frequency Response: <3 Hz to > 20kHz typ.(capsule). Sensitivity: 22 mV/Pa (-33 dBV/Pa)typ. Dynamic Range (capsule) 1% THD: <20dBA-150dBSPL (Capsule).
-
product
ICP Plasma System
The AXIC IsoLok® Inductively Coupled Plasma (ICP) Load-Locked Processing System from AXIC, Inc. defines a new concept in Deep Reactive Ion Etch (DRIE) and low temperature-low damage Plasma Enhanced Chemical Vapor Deposition (ICP-PECVD) plasma processing. The system is based on a modular design starting with a universal chamber and cabinet unit with ICP etch or deposition bottom electrodes available for easy installation into the chamber unit combined with a load-lock. We are confident you will find the ease of use, variety of plasma processes, serviceability and attractive pricing unsurpassed by any other plasma product in the market.
-
product
Multitype ICP Emission Spectrometers
ICPE-9800 Series
Due to their high detection sensitivity down to ppb levels, ability to analyze a broad 5 to 6-digit range of concentrations, and ability to measure multiple elements simultaneously, ICP emission spectrometers are used in a broad range of fields, such as environmental testing, pharmaceuticals, foods, chemicals, and metals. ICPE-9800 Series of simultaneous ICP atomic emission spectrometers are next-generation systems that offer the superior accuracy necessary to simultaneously and quickly analyze multiple elements regardless of their concentration levels. They also feature user-friendly software that makes analysis easy. Furthermore, the systems reduce analysis costs while providing the highest performance levels in the industry. ICPE-9800 Series systems represent the ultimate in ICP atomic emission spectrometry for environmental, pharmaceutical, food, chemical, metal, and other fields.
-
product
Precision Condenser Microphone
377C01
Performance:Nominal Microphone Diameter:1/4"Open Circuit Sensitivity 2.0 Open Circuit Sensitivity (3 dB)-54 dB re 1 V/PaFrequency Range Inherent Noise<35 Temperature Coefficient of Sensitivity (+14 to +122FHousing Material: Stainless Alloy
-
product
Inductively Coupled Plasma Spectroscopy (ICP-OES/MS), ICP Analysis Services
ICP-OES measures the light emitted at element-specific characteristic wavelengths from thermally excited analyte ions . This light emitted is separated and measured in a spectrometer, yielding an intensity measurement that can be converted to an elemental concentration by comparison with calibration standards. ICP-MS (ICP-Mass Spec) measures the masses of the element ions generated by the high temperature argon plasma. The ions created in the plasma are separated by their mass to charge ratios, enabling the identifcation and quantitation of unknown materials. ICP-MS offers extremely high sensitivity (i.e. low detection limits) for a wide range of elements
-
product
Measurement Microphone System
MK224SYS
The MK224SYS Type 1 measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 8 Hz to 18 kHz response, 50 mV/Pa sensitivity and a "A" weighted noise floor less than 14 dBA.
-
product
Structural Test ICP® Accelerometers
Conventional structural test data systems use few to several hundred sensors. Cables bundles can be complex and confusing resulting in setup errors. Sensors with TEDS (Transducer Electronic Data Sheet) allow for an internal sensor digital chip to store sensor information. This information contains descriptive identifiers that when connected to a TEDS compatible signal conditioner or data system, reads the descriptive information and automatically aligns the data system. Human error is minimized, reducing time consuming data verification or re-test. The Series 333 ICP® accelerometers, and their accessories, are designed to address the needs of multi-point modal and structural test measurement applications. This equipment was developed in conjunction with the world renowned University of Cincinnati Structural Dynamics Research Laboratory and proven in real-world testing situations. The PCB 333 Series accelerometers delivers rapid system setup, reduces human documentation errors, maintains calibration data of each sensor, allows for “Plug-and-Play” installation, reduces overall test time lowering project test costs.
-
product
Omni Measuring Microphone
PVR™ 2
Omni-directional microphone for free-field measurement. With a highly reliable circuit and a 1/4" pre-polarized condenser capsule, it boasts high stability, low distortion and low noise in performance. Its excellent flat frequency response makes it ideal for sonic analysis systems and recording.
-
product
complete 1/2 inch Type 1 Measurement Microphone System
PS9200KIT
A complete 1/2 inch Type 1 measurement microphone system. Available in 1 Inch and 1/4 Inch versions. The heart of the KIT is the 1/2 inch Type 1 measurement microphone. A selection of 4 different 1/2 inch capsules is offered. These include models with frequency responses to 40 kHz, noise floors of 12 dBA in both free field and pressure versions. Microphone sensitivities range from 12 to 50 mV/Pa.
-
product
Microphone Preamplifier
426B31
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
product
Measurement Microphones
SCM
The SCM measurement microphone is a robust, free- field microphone designed for the rigorous environment of a production line without compromising the accuracy, precision, and stability required for R&D.
-
product
Microphone Preamps
Applied Research and Technolgy
Unlock your mic's full potential with advanced features like variable impedance, mid-side processing, and real tube warmth.
-
product
Externally Polarized Precision Condenser Microphones & Preamplifiers
Externally polarized microphones set the initial standard for all acoustic test and measurement applications. They rely on a dedicated 200V power supply and specialized cables with 7-pin LEMO® connectors. Their straightforward design supports a wide product range. Often chosen as replacements for existing models or when prepolarized alternatives are unavailable.
-
product
Microphone Calibration Workstation
9350C
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
product
Microphone Pre-Amp Audio Interfaces
Analog Devices mic pre-amp audio interfaces provide a high fidelity, high performance solution for audio products. Specifications for this family include ultralow 1.5 dB noise figures, 140 dB gain range, and high gain capability. Operating in an extended industrial temperature range of –40°C to +85°C, this portfolio of mic pre-amp audio interfaces supports many applications, including precision instrumentation, active filters, low noise amplifier front ends, surveillance systems, computerized voice recognition, and a variety of other industrial and consumer products. As the first choice for serious audio engineers, Analog Devices mic pre-amp audio interfaces can give your applications the performance needed to meet the most demanding specifications.
-
product
Low Noise Prepolarized Microphone
378A04
The 378A04 is a matched system that is comprised of a high sensitivity microphone and a low noise preamplifier that contains a built-in filter that enables the free-field response to remain flat over a wide frequency range. The system requires a minimum of 4 mA and measures to 6.5 dBA (5.5 dBA typical) within a cost efficient, prepolarized (0V) design. PCB's model 378A04, the industry's first prepolarized low noise microphone and preamplifier system allows you to measure extremely low amplitudes. In the past this was only possible with externally polarized solutions. With a typical noise floor of 5.5dBA, this microphone system delivers all of the benefits commonly associated with prepolarized systems.
-
product
Quartz ICP® Links
Link-style sensors measure dynamic compression and tension. They are constructed using a force ring that is under compressive pre-load between threaded mounting hardware. The threaded mounting on both ends of the sensor supports integrated link-style installations. Versions offering full-scale measurements of 10 lb to 50k lb (45 N to 220k N) compression and 30k lb (130k N) tension are available.
-
product
HEAD artificial head microphones
HSU III
The HEAD-Shoulder-Unit HSU III is an artificial head microphone for binaural recordings.
-
product
Microphone Preamplifier
426B03
Performance: Nominal Microphone Diameter:1/4"Frequency Response: (0.1 dB) (re 1 kHz)5 to 126000 Hz5 to 126000 Hz Frequency Response
-
product
USB Microphones
Easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic Is esignals with the highest quality.
-
product
Measurement Microphones
The microphone bodies contain the preamplifier. They combine high dynamic range and wide frequency range with low noise. These measurement microphones connect via the ASD Cable to the XL2 Audio and Acoustic Analyzer, e.g. for measurements at remote locations or to reduce acoustic reflections.