ICP Microphones
measure acoustic frequency, time and noise levels.
-
Product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
780989-01
-
The PCB HSTC33 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTC33 features a sensitivity range of 100 mV/g and requires a low-noise coaxial cable.
-
Product
Measurement Microphone Cartridges
-
G.R.A.S. Sound & Vibration A/S
Measurement microphones are available in many types covering various frequency ranges, dynamic ranges and application situations. Selecting a microphone involves a number of choices, which can be summarized as:
-
Product
Externally Polarized Precision Condenser Microphones & Preamplifiers
-
Externally polarized microphones set the initial standard for all acoustic test and measurement applications. They rely on a dedicated 200V power supply and specialized cables with 7-pin LEMO® connectors. Their straightforward design supports a wide product range. Often chosen as replacements for existing models or when prepolarized alternatives are unavailable.
-
Product
Precision Condenser Microphone
377B02
-
1/2" free-field, prepolarized condenser microphone, typical sensitivity= 50 mV/Pa (+/-1.5 dB), 3.15 Hz to 20 kHz (+/-2 dB).
-
Product
Sub-Miniature ICP® Pressure Sensors
-
PCB's sub-miniature 105C dynamic pressure sensors are specifically designed to fit into tight spaces where mounting space is at a premium.
-
Product
Ultraminiature Microphone
MB-2200M10
-
MB-2200M10 is an ultra compact and lightweight microphone that enables measurement in narrow spaces, where have been difficult to install, without giving influence to the sound field.Its compact and lightweight features make you possible to perform measurements in a limited space, such as multi-point measurement, and measurement near the sound source. As CCLD type, the MB-2200M10 can be connected to Ono Sokki’s FFT Analyzer or CCLD supported devices.
-
Product
Precision Condenser Microphone
2575
-
Performance:Nominal Microphone Diameter1"1" Frequency Response: Characteristic (at 0 incidence) Random IncidenceRandom Incidence Open Circuit Sensitivity: 45 mV/Pa Resonant Frequency (90 Phase Shift)8000 Hz8000 Hz[1] Inherent Noise<10 dB(A) re 20 Pa<10 dBTemperature Range (Operating)TBD FTBD C Humidity Coefficient of Sensitivity (0 to 95%, non-condensing)0.001 dB/%RH
-
Product
Microphone Calibrators
Trig-Tek™ 402H & 402PSI
-
Portable, self-contained, high-intensity acoustic microphone calibration source
-
Product
SparkFun Analog MEMS Microphone Breakout
SPH8878LR5H-1
-
The SparkFun Analog MEMS Microphone Breakout makes it easy to work with the SPH8878LR5H-1 analog microphone from Knowles. This board features an OpAmp to bring the output of the microphone to a usable level, allowing you to plug directly into an ADC on a microcontroller or something like the SparkFun Spectrum Shield.
-
Product
Microphone Preamplifier
426B31
-
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
Product
23KHZ Measurement Microphone
M23
-
The M23 is a precision engineered 23kHz omnidirectional measurement microphone ideally suited for acoustical measurements including loudspeaker design and quality control, sound system setup and troubleshooting, room acoustics, or any application where an accurate free-field measurement microphone is required.
-
Product
Low Outgassing ICP® Accelerometers
-
Low Outgassing ICP® (IEPE) Accelerometer Types & Their Applications.
-
Product
On-line ICP / ICP-MS Sample Preparation System
SDX ʜᴘʟᴅ
-
The SDXHPLD system combines the proven ASX‑560 autosampler with a novel vortex mixing dilution accessory. The system dilutes in the same way you do by hand: volume-to-volume dilution, using a highly accurate syringe pump. But it also goes an additional step to vortex mix the resulting dilution prior to sample introduction to ICP and ICP-MS.The SDX employs vortex mixing to promote homogenization of a sample to ensure accurate and precise analysis following dilution. The variety of sample matrices submitted for trace element analysis necessitates the need for mixing. This long overdue capability improves data quality by fully homogenizing a dilution mixture rather than performing in-line combination.The SDXHPLD is a straight-forward, fully-integrated solution for automated dilution of aqueous and acid base sample prep for ICP or ICP-MS.
-
Product
IDevice Calibrated Measurement Microphone
IMM-6
-
The Dayton Audio IMM-6 is a professional-quality measurement and recording microphone that is designed to work with the entire suite of Apple “iDevices” – iPad, iPhone, and iPod. The rugged construction and compact size make it the perfect companion for audio professionals who must work on-location performing acoustic analysis, monitoring audio levels, or recording. Each IMM-6 is individually hand-calibrated using a laboratory-standard measurement microphone, for consistent, repeatable measurements that match the level of precision previously offered only by expensive stand-alone microphones.
-
Product
ICP® Accelerometers With Excellent Thermal Stability
-
The single and triaxial ICP® accelerometers are designed with a low temperature coefficient, wide operating temperature range, and good broadband measurement resolution, making them ideal for any vibration measurement requiring tight control of amplitude sensitivity over a wide thermal gradient. To alleviate the effects of high frequency overloads caused by metal-to-metal inputs, a low pass filter has been incorporated in all models, ensuring accurate data in the frequency range of interest.
-
Product
USB Microphones
-
Easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic Is esignals with the highest quality.
-
Product
Precision Condenser Microphone
377C10
-
Performance:Nominal Microphone Diameter:1/4"CharacteristicPressure Open Circuit Sensitivity1.0 mV/Pa1.0 mV/PaFrequency Range (2 dB)4 to 70000 Hz4 to 70000 Hz Lower Limiting Frequency (-3 dB)0.25 to 3.0 Hz0.25 to 3.0 Hz Resonant Frequency (90 Phase Shift)65000 Hz65000 HzHumidity Coefficient of Sensitivity (0 to 100%, non-condensing)0.0012 dB/%RH0.0012 dB/%
-
Product
Probes, Sensors, Measurement Microphones, Calibrators, Accessories
-
Passive Probes, Active Probes, USB Isolators, Noise & Vibration Sensors & Accessories, Electro-Acoustic Test Accessories
-
Product
MEMS Microphones
-
A MEMS microphone is an electro-acoustic transducer housing a sensor (MEMS) and an application-specific integrated circuit (ASIC) in a single package.
-
Product
ICP OES spectrometer (ICP AES)
-
SPECTRO Analytical Instruments GmbH
ICP OES spectrometer (ICP AES) for the rapid analysis of elements in a variety of matrices including aqueous, semi-conductor, petrochemical, soil, metallurgical and slurries
-
Product
Ground Isolated ICP® Pressure Sensors For High Frequency
-
PCB® Series 102B is a ground isolated version of the Series 113B. These sensors have all of the same features and benefits of the 113B Series, plus the added benefit of isolation, which helps prevent ground loop problems. This series can accommodate an optional ablative coating (Prefix: CA) to protect the diaphragm from thermal shock in flash-temperature applications.
-
Product
PCB Triaxial Accelerometer, 1000mV/g, ICP®(IEPE), 0.5Hz-3kHz
784815-01
-
The PCB Miniature Triaxial Accelerometer helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB Miniature Triaxial Accelerometer features a sensitivity range of 1000 mV/g and requires the PCB lightweight cable with 4-socket plugs.
-
Product
Microphone Preamplifier
426A05
-
Preamplifier for 1/4" side vented prepolarized microphones.
-
Product
USB Controlled Loudspeaker & Microphone Test Interface
AmpConnect™ ISC
-
AmpConnect ISC is an all-in-one audio interface that simplifies your test setup and operation. It is a single, rugged, rack-mountable piece of hardware containing a high-accuracy audio interface, impedance box, amplifier, headphone amplifier, 2 microphone power supplies and digital I/O. It replaces multiple hardware devices, connecting to your computer via a single USB cable, and it is fully controlled by SoundCheck. This simplifies setup and calibration, eliminates cabling and reduces connectivity errors, as well as reducing overall system cost.
-
Product
Ultrasound Microphone
M500
-
The M500 microphone is easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic signals with the highest quality. For recording with the M500, the BatSound Touch or BatSound Touch Lite software is used.
-
Product
Measuring Microphone
AWA14400
-
Hangzhou Aihua Instruments Co., Ltd.
*Precision acoustic measurements*Pressure variation measurements
-
Product
Microphone Preamps
-
Applied Research and Technolgy
Unlock your mic's full potential with advanced features like variable impedance, mid-side processing, and real tube warmth.
-
Product
Microphone Measurement Capsule
TG MM1W
-
Interchangeable measurement microphone capsule for TG 1000 handheld transmittersTo calibrate ELA and PA systems in the theatre, at live concerts or at festivals
-
Product
SparkFun Electret Microphone Breakout
-
This small breakout board couples an Electret microphone (100Hz--10kHz) with a 60x mic preamplifier to amplify the sounds of voice, claps, door knocks or any sounds loud enough to be picked up by a microcontroller’s analog-to-digital converter. Each breakout comes fully assembled and works from 2.7V up to 5.5V.
-
Product
Precision Condenser Microphone
377C41
-
1/2" condenser microphone, free-field, 200 V Polarization