Shielding
Protects against or confines electromagnetic or ionizing radiation.
See Also: Shielding Effectiveness
-
Product
Integrated Potentiostat and Multiplexer
EmStatMUX8
-
Based upon the EmStat range, there are two types of multiplexers to suit most types of sensor array work. The MUX8 is the most flexible offering the ability to connect arrays made of up to eight working electrodes in two or three electrode cell types and chips sharing a reference electrode and/or counter electrode. The MUX16 is suitable for sensor arrays or chips with sixteen working electrodes all sharing a RE and/or a CE. Both instruments are suitable for laminated layer corrosion analysis.The potentiostat is controlled and powered by USB and is used with PSTrace allowing for simultaneous sampling of each channel at a rate of 25 ms/channel. Standard packaging includes a shielded cable with connections for a working, a counter and a reference electrode by means of 2 mm banana connectors and mini-crocodile clips, a stripped end, Dsub-37 terminated flat cable and a USB cable. To make connections to chips simpler the Connection Terminal is an optional extra providing clearly marked screw terminals to the electrodes and can be directly joined to the ESMUX via their D-Sub connectors.
-
Product
Log Periodic Antennas
-
A.H. Systems' offers 13 Log Periodic Antennas. Each antenna is lightweight, compact, rugged and has been manufactured to ensure maximum gain, low VSWR and high power handling capabilities. Whether testing inside a shielded enclosure or outdoors, the antennas will display efficient performance characteristics through the broad frequency range of 80 MHz to 7GHz.
-
Product
RF Shielded Enclosure, 100dB from 1MHz to 10GHz
QuietBox-100m
-
The Raymond RF QuietBox-100m line portable shielded enclosures are made from the same proven modular RF shielding materials as full size Modular RF Shielded Enclosure systems and offer the same exceptional RF Shielding Effectiveness. The QuietBox-100m is the perfect portable tabletop and laboratory enclosure where larger interior volume or higher RF Shielding Effectiveness is required.
-
Product
Micro Coax, Contact, Receiver, RG316 Double Shield
610140104
Coax Contact (Receiver)
Primary mating contact 610141104. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor – SolderShield – SolderInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 10.5 GHzVSWR 1.0225 +.05 f(GHz)Insertion Loss -√f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
Product
Micro Coax, Contact, ITA, RG316 Double Shield
610141104
Coax Contact (ITA)
Primary mating contact 610140104. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - SolderInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 10.5 GHzVSWR 1.0225 +.05 f(GHz)Insertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
Product
SCSI CABLE TESTER
ST123
-
Continuity tests alone are not sufficient to qualify SCSI cable assemblies. Proper testing of SCSI cables must include a test for correct connection of twisted pairs and shielding. Continuity tests check only that wires are making connections on both ends of a cable.Twisted pairs in the cable must be matched with the correct SCSI signal pairs - otherwise, it is possible to have a SCSI signal (signal and ground pair) placed on wires that are not in the same physical twisted pair (see diagram at right). This will cause crosstalk with resultant SCSI errors.
-
Product
Antenna, Double Ridged Guide
EM-6968 | 2.5 GHz – 7.5 GHz
-
The EM-6968 Double Ridged Guide Antenna is a linearly polarized broadband antenna for specification compliance testing. The versatile EM-6968 is constructed of rugged aluminum, which makes it excellent for use under severe field conditions and the size makes it suitable for use in the limited space of a shielded enclosure.
-
Product
SHB12X-B12X, 73-Pin, Male InfiniBand to 73-Pin, Male InfiniBand, 100 Ohm, Shielded LVDS Cable 2m
192344-02
LVDS Cable
The SHB12X-B12X LVDS Cable connects the 12X InfiniBand connector on PXIe-656x LVDS instruments or some NI 658x LVDS Adapter Modules for FlexRIO with other NI accessories such as the SMA-2164 to break out cable signals for direct access. It is a shielded, 100 ohm cable that is offered in various lengths.