Hydrogen Frequency Standards
Microwave Amplification by Stimulated Emission of Radiation
See Also: Frequency Standards, Rubidium Standards, Hydrogen Masers
-
Product
Conformance Calibration Standard Test Card for UPC/EAN Symbol Verifiers
AI-CCS-UPC/EAN-E Rev S
-
For those who prefer a traditional vertical format calibration test card, APPLIED IMAGE offers our new Conformance Calibration Standard Enhanced for UPC/EAN Bar Code Symbol Verifiers. The new standard complies with both the ANSI X3.182 and ISO 15416 standards and is ideal for testing of verifiers, scanners, and other UPC bar reading equipment as well as a tool for training new operators to assure proper “methodology' in the use of verifiers.
-
Product
Capacitance Standard Set, 0.01uF To 10uF
16380C
-
The 16380C is a standard capacitor set consisting of three precision capacitors - 0.01uF (16385A), 0.1uF (16386A), 1uF (16387A),and an optional 10uF (16388A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-10
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-1C1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
DC Josephson Voltage Standard
-
The system enables a number of calibration and measurement functions for dc voltages:*Calibration of secondary standards*Calibration of linearities and accuracies of dc voltmeters in the measuring range from 0 to ± 10 V.*Extremely exact output of any reference voltages*Direct comparison of two voltage standard measuring systemsNo other measuring system in the world offers such a variety with the highest precision.
-
Product
4-Port 9 GHz Analyzer, Frequency Extension Compatible
C4409
-
C4409 Vector Network Analyzer delivers industry-leading dynamic range and sweep speed, with all the features engineers have come to expect included standard in our software. This VNA is frequency extender compatible and is the anchor network analyzer for the CobaltFx frequency extender system.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T30-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4L
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
ITA, G10, 10 Module, 0.5" Standard thickness
410104123
ITA
ITA, G10, 10 Module, 0.5" Standard ThicknessUses VPC 90 Series Modules.
-
Product
Standard Voltage 37 Pin D-Type Connectors
-
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72F-4
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Full-Featured Open Source Free Implementation for the Object Management Group (OMG) Data Distribution Service for Real-Time Systems Standard
DDS Community
-
The DDS Community Edition is a full-featured open source, genuinely free implementation of the Object Management Group (OMG) Data Distribution Service for Real-Time Systems standard. Full-featured Apache license version 2.0 open source Data Distribution Service (DDS) implementation.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40G
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
CPCI-S.0 Standard Compliant Peripheral Carrier Board
MIC-3810
Carrier Board
The carrier board provides a PCIe x16 connector for standard PCIe x8, PCIe x4, PCIe x1 PCIExpress® cards supporting PCIe Gen3 speeds. The carrier board can accommodate cards with maximum dimensions of 176 x 68.9 mm (6.9" x 2.7" inches).
-
Product
Ferrite Low Frequency Transducers
-
Ceramic magnetic design able to provide high-power handling and low distortion for the most demanding speaker manufacturers.
-
Product
Standard Clamp Meters
-
For extreme temperatures, choose an analog clamp meter that can measure amps and volts without needing batteries.
-
Product
1202a High Frequency Distribution
-
Precise Time and Frequency, Inc.
The ptf 1202A High Frequency Distribution amplifier provides high performance frequency references for laboratory or system use requiring distribution at frequencies of 30MHz and above.The ptf 1202A is especially designed to distribute the high frequency input signal to 12 separate outputs, with minimum signal distortion and maximum isolation between individual output signals.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I40-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Amplifier for the Frequency Range from 2 Hz to 50,000 Hz.s
Trig-Tek™ 203M
Amplifier
Versatile amplifier covers the frequency range from 2 Hz to 50,000 Hz.s and provides has three simultaneous outputs
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T36-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Rack Module with Standard Contactors without Anti-Harmonic filters
MOD Rack
-
Lifasa - International Capacitors, SA
The MOD-RACK control units include, in a compact form, all the components necessary for the operation of a step of a standard capacitor bank. MOD-RACK modules are divided into two basic blocks: power block and control block. The two blocks are mounted in a small frame to be installed in an electrical panel.
-
Product
Standard - 5.00 (142.00) - 8.30 (235.00) Feed Through Probe
P3325-0
-
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 645Overall Length (mm): 16.38
-
Product
European Standard for Remote Reading of Measuring Devices
M-Bus
-
M-Bus (Meter-Bus) is a European standard for remote reading of measuring devices. M-Bus is predominantly used in buildings, for example in electricity meters, gas meters, water meters or other types of consumption meters. It is also used for various sensors and actuators.
-
Product
Individual UPC Bar Code Standards
-
The UPC Verification Calibration standards are a unique set of symbols that assures an exact and reliable primary bar code standard exists for UPC codes based on ANSI X3.182/ISO 15416 methodology. These standards assures that manufactures of verification equipment, scanners, QC labs and end users now have an accurate basis for checking the measurement capabilities of their equipment. These standards are intended as a fundamental calibration tool for an QC program, providing a continuous scale from best to worse case characteristics of each parameter. With complete NIST traceable data supplied, it is ideally suited to those requiring traceability, such as ISO certification. Each symbol is individually calibrated to ANSI X3.182/ISO 15416 standards using a custom built microdensitometer. These cards are supplied calibrated for use with a 6 mil scan aperture and 660nm wavelength. (calibration wit other aperture sizes or wavelengths is available)
-
Product
High Frequency Current Transformers
-
Osborne High Frequency Current Transformers operate at frequencies higher than 50/60 Hertz. Their purpose is to reduce high frequency system currents to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when high frequency current transformers are to be used for power measuring applications.
-
Product
Frequency Expansion Modules
-
bsw TestSystems & Consulting AG
Up To 1.5THz For Network Analyzers Modern communication standards, like for instance 5G, place high demands on components (mixers, amplifiers, antennas, etc.), which have to be examined in high frequency bands (millimeter waves); the requirements include: broad frequency coverage, sufficient output power to operate the components under compression, high dynamic range and stability as well as a reduced dynamic content within the spectrum.
-
Product
Double Voltage Double Frequency Generator Setup
DVDF
-
This test setup is generally used to perform induced voltage test on the transformers. This set up consists of the USED motor and generator combination to develop the required voltage and frequency. Both generating unit and the drive motor are mounted on a common metallic frame.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Frequency Response Analyzers
7400 Series
-
The Venable Model 7400 Series is the top of the line in Venable performance, supplying 4 channels for increased testing, measurement and analysis functionality. Originally designed for measuring 3-phase impedance and source and load simultaneously, the Model 7400 is a robust solution for organizations requiring high availability for high volume and/or simultaneous testing.





























