Standard Transformers
-
Product
Rectifier Transformers
-
Osborne’s Rectifier Transformers are used in conjunction with various rectification configurations to convert AC input to DC output(s). Key characteristics include regulation, transformer utilization and AC ripple. Osborne rectifier transformer designs are often engineered to operate in advanced rectifier circuit applications.
-
Product
Transformer Ratio Meter
TRM 1000
-
AJIT Transformer Ratio Meters are the most modern turn's radio meters widely used to test the turn's ratio of high voltage windings, to low voltage windings, of Transformer. These meters are accurate, compact & light in weight.
-
Product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-F200-1
Switch Probe
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30J
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
Product
Nanolattice Standards for Analytical Instruments
-
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of Electron and Atomic Force Microscopes (AFM). Make the grade, with the highest quality pitch standard of its kind available.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T24-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Current Transformer Analyzer/Tester
GF1061
-
Beijing GFUVE Electronics Co.,Ltd.
Portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.
-
Product
Standard 1.00 (28.00) - 2.30 (65.00) Non Replaceable General Purpose Probe
P2532-1
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 156Test Center (mm): 3.96Full Travel (mil): 139Full Travel (mm): 3.53Recommended Travel (mil): 93Recommended Travel (mm): 2.36Overall Length (mil): 812Overall Length (mm): 20.62Rec. Mounting Hole Size (mil): 94.5Rec. Mounting Hole Size (mm): 2.40Recommended Drill Size: #41 or 2.40 mm
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, Type-N, 50 Ohm
85032F
-
The Keysight 85032F calibration kit contains precision 50 ohm type-N standards used to calibrate Keysight network analyzers. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 9 GHz.
-
Product
15T Standard Running Line Monitor
RLM15T-3.0-S
-
The DLM 15T Running Line Monitor measures the tension on a rope passing through its three wheels. Typically used in cable laying and winch operations to measure and record line tension the robust design has become an industry standard. The monitor can be supplied as a separate item for integration with customers existing PLC’s or with a DLM digital display/HMI touch screen display.
-
Product
Benchtop Rubidium Frequency Standard
FS725
-
Stanford Research Systems, Inc.
The FS725 integrates a rubidium oscillator (SRS model PRS10), a low-noise AC power supply, and distribution amplifiers in a compact, half-width 2U chassis.
-
Product
Transformer Monitors
-
The Transformer Advantage is a precision temperature monitor for liquid-immersed power and distribution transformers. It is rugged, fully electronic and field configurable. With Transformer Advantage, users can extend transformer life, utilize maximum capacity and reduce maintenance costs.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2T
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Split Core Current Transformer
-
Beijing GFUVE Electronics Co.,Ltd.
Have a "split" in the core that allows the CTs to open and be placed around the conductor without having to disconnect the conductor or disrupt the wiring.
-
Product
Digital & ARINC Standards Display Panel
TA-3001
-
This is our soon to be introduced Digital Standards Panel. (2ND QTR) This panel is available with or without a Precision Resolver drive. Included on the panel are four digital displays; TA-902 API, TA903-01 OBI, TA903-02 Distance and a TA903-03 serial distance display. This panel when paired with the TA-3000 GPS/FMS test panel will make one of the most capable testing solutions available today
-
Product
Standard 0.66 (18.70) - 4.50 (128.00) Battery Probe
CP-2LB-4
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 39Full Travel (mm): 1.00Recommended Travel (mil): 30Recommended Travel (mm): 0.75Overall Length (mil): 158Overall Length (mm): 4.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Transformer Short Circuit Impedance Tester
JYW6300
-
This instrument is mainly applicable to low voltage load impedance test of 35kV and above power main transformers (single phase or three phases) in ex-works routine tests, overhaul tests, pre-tests, and acceptance tests.
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-2V1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1V-4
-
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72H-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Transformer Resistance Testing
-
Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime. If you fail to maintain your transformer with regular insulation resistance testing (as can be carried out by the Megger Transformer Ohmmeter (MTO) series of transformer test equipment) then it’s likely to fail before reaching its maximum operating life.
-
Product
Standard Serial Page EEPROM
-
Serial Page EEPROM is a high-density, page-erasable SPI EEPROM memory that combines flexibility, performance, and ultra-low power. The Serial Page EEPROM with proprietary NVM cell technology delivers fast erase/write performance with high cycling endurance and robust retention. The new architecture allows fast wake up and byte flexibility, as well as block management and fast quad output, while keeping current surge and energy budget at very low levels.
-
Product
L.V. Current Transformers
-
ENTES LV Current Transformers are measuring transformers which transform the primary current by a specified ratio to its secondary side with a phase difference of 0 degrees. They provide isolation of the relays and measuring devices from the HV side of the network.
-
Product
Standard 3.00 (85.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
G-S-F
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
Instrument Transformer Comparator
PMT20010
-
Power Measurement Technologies Inc.
The PMT20010 Comparator is an automatically balancing bridge that measures the accuracy of instrumentation potential and current transformers.
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
Mechanical Calibration Kit
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
Calibrated Diffuse Reflectance Standards
-
Diffuse reflection calibration standards in synthetic ODM and ODMP material
-
Product
Standard Voltage 50 Pin D-Type Connectors for Pickering
-
The connectors below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64