Thermocouple Calibrators
-
product
Compact Temperature Calibrator
CTC Series
AMETEK Sensors, Test & Calibration
CTC Series Compact Temperature Calibrator from AMETEK Sensors, Test & Calibrations is engineered for “advanced simplicity,” incorporating a number of useful features that greatly extend the range and functionality of the popular temperature calibrator. The CTC Series offers an easy-to-read, full-color display with improved navigation that provides easy access to the calibrator’s latest features. The CTC Series now contains an auto step function with up to 12 preset temperature points, an optimized switch test with automatic up and down test runs, assisted manual calibration using pre-defined temperature points, and memory to store up to 5 calibration processes.
-
product
4-in-1 OSLT Calibration Kit, DC to 50 GHz, 2.4 mm (m)
CK564A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
PAT Calibration Checkboxes
Seaward's special PAT calibration checkboxes are designed to provide a fast and simple means of confirming that test readings remain effective during those working periods between formal re-calibration.
-
product
Gauge Type T Thermocouple Wire
W-TW-40
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
product
AC Calibration Standard
1U647-001
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
product
Portable Calibrator
MC141
Voltage range from 0 to 750 V DC/AC with uncertainty 0.01% Current range from 0 to 2 A DC/AC with uncertainty 0.02 % Calibrated sinusoidal output signal DC - 1kHz. Set standard resistors from 10 Ohm to 100 MOhm in decade values with uncertainty 0.02 %. TC temperature sensor simulation R, S, B, J, T, E, K, N in range from -250 oC to 1850 oC
-
product
MAX31855 T-Type Thermocouple Arduino Shield
SEN-30004-T03
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino.Each order comes with one board and a set of four female, long extension, headers that can be soldered to the board. If stacking two of these modules on top of each other, please order both a Ch 0-3 and a Ch 4-7 board, as well as an additional set of headers for stacking. We're working on sourcing even longer headers, but the ones currently available are not long enough to stack as-is (they need to be double-stacked).The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or MegaNote: we also offer a universal version of this board in a smaller for factor, the SEN-30003-T.FeaturesType-specific, miniature-sized vertical thermocouple connectors (vertical flat blades, see pics)Measures four (4) thermocouple channels, full extended range.Boards are stackable. Up to 8 thermocouple channels may be connected to an Arduino.14-bit SPI interfacePlugs directly into an Arduino Uno or Mega form factor with built-in voltage level translation on-board.Standard Arduino female headers required for easy configuration, one set included with order (1-6x1, 2-8x1, 1-10x1 0.1" female stackable headers), not soldered on.Detects shorts to GND or VccDetects open thermocoupleOther versions available (K, J, and T stocked). Contact Customer Service to place a custom order.Mounting holes for 4-40 sized screwsConnections are spaced for 0.1" pin headerDesigned, manufactured, tested and shipped from the USA The MAX31855T supports a measured temperature range of -270C-400C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
product
Calibrator, 0 to 24 mA, Current, 185 mm, 78 mm, 38 mm, ± 0.5%, 265 g
72-6694
*Adjustable 0 to 24 mA current source*Current calibrator drives loads up to 500 Ω*Large LCD display*Sampling Time : Approximately 0.4 seconds*Over Input Indicator : 1*Operating Temperature : 0°C to 50°C ( 32°F to 122°F)*Size : 185 × 78 × 38 mm (7.3 × 3 × 1.5 inches)*Weight : 265 g (0.58 lb) including battery*Requires one 9 V battery - not included*12 month limited warranty *view Terms & Conditions for details
-
product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm
CK521A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Open-Short-Load RF calibration kits
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
product
DC to 120 GHz USB Thermocouple Power Sensor
U8489A
The U8480 Series is the fastest USB thermocouple sensor in the world without compromising the best-in-class linearity of the legacy 8480/N8480 Series thermocouple sensors. The U8489A covers the widest frequency range, DC to 120 GHz.
-
product
Argon Calibration Source
AR-1
The AR-1 produces low-pressure argon emission lines from 696-1704 nm for use in performing fast, reliable spectrometer wavelength calibrations.
-
product
Calibration Lead Precision Resistor - Dual
40-975-009-SL2
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
product
Compensation Block for Thermocouple Simulator Modules
40-965-912
The Compensation Block is a accessory specifically designed for the 41-760 and 41-761 Millivolt Thermocouple Simulator modules. This block will give the user the temperature of the front panel junction of the module to cabling. This data can then be combined with other factors, temperature on the other end of the cable for example, to compensate the thermocouple hence increase the accuracy.
-
product
DOSE CALIBRATOR
CRC®-55tR
As a combination of the new CRC®-55tR Dose Calibrator and Well Counter, the CRC-55tW dose calibrators provide advanced features with the speed and accuracy you need to measure activity and prepare doses.
-
product
K Thermocouple Penetration Probe
TP659
“K” Type thermocouple penetration probe. Tolerance according to IEC 60584-2 standard.
-
product
Exhaust Gas and Wheel Space Thermocouple
EGT
AMETEK Exhaust Gas (EGT) and Wheel Space Frame Turbine Thermocouples meet the specific operational and performance requirements for REPLACEMENT and RETROFIT Frame gas turbine applications. AMETEK's expertise in solving creep, stress, rupture, corrosion, EMF drift, and other problems affecting sensor performance has resulted in a robust line of single and dual element thermocouple designs. Typical applications include wheel space and exhaust gas temperature monitoring.
-
product
Temperature Calibrators
Ensuring process temperature accuracy involves calibrating not only the system’s electronic temperature signals, but also the very temperature sensors that initiate those signals. Rugged Fluke handheld temperature calibrators source and measure RTDs and thermocouples, power transmitters, and store data. Fluke Calibration temperature sources cover temperatures from -45 °C to 1200 °C and include handheld, portable, and benchtop calibrators. Infrared thermometer calibrators and reference measurement thermometers ensure every necessary tool is available to you.
-
product
Calibration Sources
Up to an absolute accuracy of 60 MHz standard HighFinesse Wavelength Meters feature auto-calibration by integrated calibration sources. This way highest accuracy and stability of measurements with our wavemeters is guaranteed.
-
product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
product
Multiport Calibration Assistant
S95552B
The S95552B software application flexibly creates and manages calibration sets for multiport measurements. This software enables you to combine multiple calibration sets with independent test ports as one calibration set with a greater number of test ports. The software also offers a way to re-calibrate using a certain set of test ports to refresh the calibration set.
-
product
Calibration and Measurement Services
A uniform light source which provides spatially uniform luminance and illuminance for flat-field correction and calibration imaging systems, calibration photometers and spectroradiometers.
-
product
Oscilloscope, Calibrated, 2 Channel, 100 MHz, 1 GSPS, 25 kpts, 3.5 ns
72-8710A CAL
The 72-8710A CAL from Tenma is a digital storage oscilloscope with 100MHz bandwidth, 2 analogue channels. The digital storage oscilloscope provides a complete set of trigger modes including edge, pulse, alternate and storage modes including set-up, wave, bitmap. It has a 7 inches wide screen LCD display and supports plug and play USB storage device. Communication with and remote control of computer through the USB device.
-
product
Calibration Light Sources
An adjustable mount for Sciencetech''s line of calibration pen lamps.Power supply and pen lamp are not included. See the calibration sources brochure for more information.
-
product
Frequency Calibrator
VCH-313
The frequency calibrator VCH-313 is designed to determine the frequency error and calibrate frequency standards of various types based on the signals of the NSC SNS GLONASS/GPS .
-
product
Microphone Calibrators
Trig-Tek™ 402H & 402PSI
Portable, self-contained, high-intensity acoustic microphone calibration source
-
product
Electronic Calibration Module (ECal), 50 GHz, 2.4 Mm, 2-port
N4693D
The Keysight N4693D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4693D is a precision 2-port ECal module that supports 2.4 mm connectors up to 50 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4693D is included for securing your ECal module and accessories.
-
product
V/mA Process Calibrator
Model KM-CAL-907
Kusam Electrical Industries Limited
This is a source and measure type of calibrator and it gives high accuracy of 0.02% . It has dual display. 5 digits display for measure and 6 digits display for source & white LED for backlight.
-
product
Automatic Meter Calibration Console
PMT40600
Power Measurement Technologies Inc.
Provides Measurement Canada compliant, fully automated testing of single and polyphase electrical energy and demand meters. Amplifier technology provides stable, low distortion, four-quadrant dynamic loads up to 600VAC and 200 amperes.
-
product
Thermocouple Power Sensors
N8482H
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.