Flux
the rate of flow.
-
Product
Phosphorus Valved Cracker
-
The patented Valved Cracker for Phosphorus is uniquely tailored to provide a controlled and reproducible P2 flux from a solid phosphorus charge. The multi-zone crucible is designed for in situ conversion from commercially available red phosphorus to the more reactive white phosphorus with its advantageous evaporation characteristics.
-
Product
Selenium Valved Cracker
-
This source has multiple heating zones that can either generate cracked or uncracked selenium flux while resisting the chemical attack from the corrosive vapor. The unrivaled convenience and flux control are maintained without depleting the source material via an all-metal needle valve. Excellent results have been reported producing blue/green LED and laser diode devices.
-
Product
Corrosive Series Valved Cracker
-
With the superior flux control of the Corrosive Series Valved Cracker, complex structures not possible with conventional thermally controlled sources can be achieved. Mixed Group V layers of varying compositions can be grown without the frequent recalibration procedures necessary when using standard sources. SIMS analysis of a continuously graded GaAs1-xSbx layer demonstrates the excellent flux control available when using two Group V valved crackers, with identical results achieved at two different growth rates.
-
Product
L.V.D.T Products
-
Columbia Research Laboratories
Columbia's L.V.D.T.'s are designed for the most demanding high temperature military and industrial applications where maximum life under adverse conditions is required. The corrosion resistant stainless steel housing provides effective shielding to contain the magnetic flux within the transformer, as well as providing protection against external magnetic fields. Conservative design permits the use of these transducers well beyond their specific linear range with minimum loss of accuracy.
-
Product
Fluxmeter
-
Measures changes in magnetic flux, as detected through a Helmholtz or similar coil arrangement.
-
Product
Irradiance Probe
LPUVC01
-
The LPUVC01 probe measures irradiance (W/m2) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m2) in the UVC (200 nm…280 nm) spectral range.
-
Product
Polarity Tester
PT-1
-
International Electro-Magnetics, Inc.
The PT-1 provides a simple and easy way to determine the relative polarity of coil windings. It allows for an in-process test that takes a minimum of time to perform. By placing a coil on the platform and making connection to the start and end of a winding, a test signal is induced in the winding. The induced signal is low level and completely safe for the operator. By comparing the test signal phase of the coil under the test output, the relative polarity is indicated by the Red/Green LED. The tester operates by inducing a signal voltage in the coil under test by means of a magnetic flux field. The field is generated by a coil located in the probe base. The coil configuration is designed to provide optimum field distribution. We have also applied this basic circuit to a 5-channel scanning unit.
-
Product
Underwater Quantum Sensor
LI-192
-
The LI-192 Underwater Quantum Sensor measures PAR from all angles in one hemisphere. The LI-192 works in air or underwater at depths up to 560 meters. The measurements are cosine corrected and typically expressed as Photosynthetic Photon Flux Density (PPFD). For simultaneous measurements of downwelling and upwelling PAR, two sensors can be mounted on the 2009S Lowering Frame.
-
Product
Single Filament Sources
-
Get a cost-effective solution that’s ideal for your high-volume, high-value MBE process needs with reliable Veeco Single Filament Sources. They feature dependable band thermocouples and single heater filaments for 750-1200°C operation. Three system configurations, and many crucible sizes, are available. All offer stable and consistent fluxes of high vapor pressure materials.
-
Product
Specialty Instruments
-
Advanced Thermal Solutions, Inc.
ATS offers a variety of unique specialty instruments, designed for specific applications across the electronics industry. These instruments range from providing heat flux measurements and cold plate characterization, to precise isothermal surface temperature control and fan flow characterization.
-
Product
Downward-Looking SUMO Source For Gallium And Indium
-
Attain large capacity, excellent flux uniformity, negligible shutter flux transients, and minimal depletion effects with Veeco’s Downward-Looking SUMO® Source for MBE. It combines a dual filament source with an asymmetric SUMO crucible featuring a narrow offset orifice and tapered exit cone with hot-lip heating. Result: excellent material quality, low defect counts, and good thickness uniformity. NOTE: This source is not for use with aluminum.
-
Product
Integrating Sphere Systems
-
An optical device for various purposes such as. measuring the radiant flux (optical power) from a laser diode, light-emitting diode (LED) or bulb.
-
Product
Electromagnet
-
The electromagnet can generate strong magnetic fields for experimental applications. Depending on the required magnetic flux density and Equipment under test volume the air gap can be adjustedcontinuously. The magnet poles come with conical shape close to the test volume to improve accessability and to optimize the achievable magnetic flux density.
-
Product
Magnetic Field And Permeability Measurement
MAGNETOMAT 1.790
-
Foerster Instruments, Incorporated
The MAGNETOMAT 1.790 is a measuring system for the precision detection of magnetic flux density and relative permeability. The MAGNETOMAT software is used for displaying the measured values and saving and exporting data. The wide range of probes facilitates optimal adjustment to the conditions of the application, such as the measurement of relative permeability within the scope of the quality control of stainless steel and low-permeable (non-magnetic) alloys. Further applications include the long-term monitoring of the magnetic environment, e.g. prior to installing magnetically sensitive devices, and the localization of ferrite enclosures in stainless steel and NE materials. Changes in material (sulfidation, degradation of lamination, structural changes) can also be proven thanks to permeability comparative measurements.
-
Product
Integrating Spheres
IP-Series
-
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
Product
Magnetic Field and Permeability Measurement
MAGNETOSCOP® 1.070
-
Foerster Instruments, Incorporated
The MAGNETOSCOP 1.070 is a portable magnetometer system with microprocessor and probes for measuring the magnetic flux density as an absolute or differential value (gradient). It has a USB port for simple data transfer and an SD card for saving measurement data and parameters. The measuring system also facilitates the recognition and saving of peak values and the adjustment of thresholds for limit values. The unit can be used for series and individual measurements. The data can be easily analyzed and documented with the PC software included in the scope of delivery. The MAGNETOSCOP 1.070 thus facilitates the portable and fast measurement of the relative permeability within the scope of the quality control of stainless steel and low-permeable (non-magnetic) alloys as well as the localization of ferrite enclosures. Changes in material (sulfidation, degradation of lamination, structural changes) can also be proven thanks to permeability comparative measurements.
-
Product
Surface Contamination Monitors
-
Small-sized devices for measuring the ambient dose equivalent rate and the ambient dose equivalent of X-ray and gamma radiation, as well as measuring the flux density of beta particles (AT6130).
-
Product
Radiometric Detectors
-
Radiometric detectors are built by using selected, stability tested high-grade Si-photovoltaic cells. They are all equipped with individually produced and matched color glass filters. They are available in different sizes for irradiance and radiant flux measurement, both in temperature stabilized laboratory and general purpose form.
-
Product
Heat, Vapor, and Carbon-Dioxide Flux Sensors
-
Heat, vapor, and carbon-dioxide flux sensors are typically used in eddy-covariance systems to measure exchanges of carbon dioxide, water vapor, and heat between the surface of the earth and the atmosphere.
-
Product
NR01 net radiometer
-
Hukseflux Thermal Sensors B.V.
NR01 is a market leading 4-component net radiation sensor, mostly used in scientific-grade energy balance and surface flux studies. It offers 4 separate measurements of solar and longwave radiation, facing both up and down. NR01 owes its popularity to its excellent price / performance ratio and major improvements relative to comparable instruments. These advantages include weight, ease of levelling, solar offsets in the longwave measurement and pyrgeometer heating, reducing measurement errors caused by dew deposition.
-
Product
Multiplex Optical Maintenance Meter
LS280
-
LS280 is used to measure optical maintenance factor for high power LEDs, LED module, LED bulb or other LED luminaries. It is the important measuring equipment for performing the reliability of illuminants. • Freely set the time interval and time extent for automatic measurement • LCD Display, connect with PC via RS232 and English version software. • The test results can export Excel or PDF format and easy to compare. It can be saved by LS280 software or by USB directly. • The engineer can do LED life analysis based on the LS280 test results. • LS280 worked with High Power LED Aging Test (LS600), Multiplex LED Temperature Test (TMP-8/TMP-16) and High and Low Temperature & Humidity Chamber (GDJS-*B), it can do Flux VS Temperature VS Time, which is a perfect instrument system to meet LM-80 request.
-
Product
0.3M Integrating Sphere For Leds Luminous Flux Test
CX-0.3S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Thesystem are composed of integrating sphere, spectroradiometer and computer to determine the spectroradiometric and colorimetric parameters, e.g. spectral power distribution, chromaticity coordinates, correlated color temperature, color rendering index, color tolerance, color difference, luminous flux, current, voltage, wattage, etc.
-
Product
Goniophotometer
-
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
Product
General Purpose Integrating Spheres
-
General Purpose Integrating Sphere Systems are designed to spatially integrate radiant flux in order to measure optical radiation. The spheres can be coupled with a sensor to create radiometers, photometers, or spectroradiometers in order to measure the total geometric flux emanating from a light source or the flux density of an illuminated area. Additionally, these sphere systems can be used to measure the output of high power lasers and laser diodes or to measure the reflectance and transmittance of materials.
-
Product
Light Meters For Photometry
-
Comprehensive range of solutions for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens) and luminous intensity (cd).
-
Product
High Accuracy Spectrophotocolorimeter
LMS-3000
-
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
Product
Open Loop Current Sensor
C03 30A
-
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
Product
High Power LED Photo-color-semi Automatic Selector
-
Shenzhen Chuangxin Instruments Co., Ltd.
Can divide LED in to several groups by chromatic coordinates, correlated color temperature, dominant wavelength or luminous flux.
-
Product
Integrating Sphere
-
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
Product
Total Flux Measurement Systems
-
LED’s and Luminaires must be characterized and tested for brightness and color, for production quality control and also for R&D. The Gamma Scientific Total Flux Measurement System combines our accurate Radoma Spectrometer and an integrating sphere for total flux (total power) and color measurements of LED, micro LED and Luminaires. Measurement parameters include spectrum, lumens, total power, peak and dominant wavelength, CRI, CCT, FWHM and other optical properties.