Flux
the rate of flow.
-
Product
Gaussmeter/Teslameter
Model 2100
-
The Model 2100 Gaussmeter is a fully featured, high-end Gaussmeter with a low cost Gaussmeter price. It is a compact, high accuracy, microprocessor controlled, flux density measuring instrument. The Model 2100 is capable of measuring static (DC), alternating (AC), or pulsed magnetic fields. Twelve measurement ranges allow the operator to configure the meter for maximum resolution and accuracy from 300mG (30 microTesla) to 300 kG (30 Tesla). Selecting primary measurement functions is quick and easy with dedicated front panel function keys. An easy-to-use menu allows access to user defined parameters such as upper and lower magnetic limits and relative magnetic measurements. Remote meter configuration is completely accessible using the built in RS-232 Interface or optional IEEE-488 Interface.
-
Product
Dopant Source
-
Attain precise and stable control of relatively low fluxes for dopant constituents in molecular beam epitaxy (MBE) through this compact dopant source. Its small thermal mass gives it excellent responsiveness, reproducibility, and stabilization for advanced doping profiles, plus consistent flux uniformity across an entire platen. Efficient cell heating minimizes thermal load.
-
Product
Measuring Devices for Magnetically Hard Materials
WB10
-
The WB10 Fluxmeter is designed to measure the change of magnetic flux in measurements of magnetic properties of the magnetic materials in quasi-static and slowly floating conditions. Fluxmeter is the electronic measuring device with high sensitivity, very small drift as well as very small error of integration in a long time.
-
Product
Differential Scanning Calorimeter
DSC-L600
-
The Differential Scanning Calorimeter (DSC-L600) is a powerful thermal analysis instrument that measures the heat flow of a sample as a function of time or temperature. The DSC-L600 has been designed to be a cost-effective instrument that is well suited for research or QC applications. The instrument communicates with the PC via a RS232/USB connection. The specially designed heat flux plate has demonstrated more than twice the sensitivity than other heat flow type DSC’s on the market. The reproducibility is excellent, and the noise level is virtually unnoticeable due to a precision high gain, low noise differential amplifier
-
Product
Goniophotometer
-
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
Product
Blackbody System
IR-518/301
-
Infrared Systems Development Corp.
The IR-518 Radiation Source provides an accurate, stable source of infrared radiation of known flux and spectral distribution. It can be used as a standard radiation source for the calibration of other laboratory sources, detectors, or other infrared devices requiring calibration against a standard.
-
Product
Microprocessorized fluxmeter
MSM-101
-
Mobile meter designed to measuring the quasi-static changes of magnetic flux association with induction sensors. The minimal range of meter is equal 0.001Wb/V and drift under 7x10-6Wb/min.
-
Product
Measuring Stations
-
The main application is the measurement of the flux density on the surface of multipole magnets or components with magnets. A large amount of measuring stations is built for rotors.
-
Product
Magnetic Particle Inspection
-
Shanghai Xianda Denshijiki Industry Co.,Ltd
Using the "leakage magnetic flux" phenomenon generated from the scratches, the magnetic powder (or fluorescent magnetic powder) of the ferromagnetic material scattered on the surface by magnetizing the specimen is adsorbed to the scratch. Observe this and detect scratches.
-
Product
Long-Term Systems
-
A long-term system from LI-COR lets you accomplish more with your multiplexed soil gas flux measurements. Connect up to 36 chambers to evaluate both spatial and temporal flux variation across a footprint of up to 2800 square meters.
-
Product
NR01 net radiometer
-
Hukseflux Thermal Sensors B.V.
NR01 is a market leading 4-component net radiation sensor, mostly used in scientific-grade energy balance and surface flux studies. It offers 4 separate measurements of solar and longwave radiation, facing both up and down. NR01 owes its popularity to its excellent price / performance ratio and major improvements relative to comparable instruments. These advantages include weight, ease of levelling, solar offsets in the longwave measurement and pyrgeometer heating, reducing measurement errors caused by dew deposition.
-
Product
Aging and Optical Attenuation Tester
LS822
-
• Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.
-
Product
Total Flux Measurement Systems
-
LED’s and Luminaires must be characterized and tested for brightness and color, for production quality control and also for R&D. The Gamma Scientific Total Flux Measurement System combines our accurate Radoma Spectrometer and an integrating sphere for total flux (total power) and color measurements of LED, micro LED and Luminaires. Measurement parameters include spectrum, lumens, total power, peak and dominant wavelength, CRI, CCT, FWHM and other optical properties.
-
Product
Digital Flux Meters
-
Digital Fluxmeter is instrument made by electronic integration principle and displays the magnetic flux digitally. It can test magnetic materials. It not only measures flux but also directly tests magnetic performance for the purpose of quality control. With the features of legible display and convenient operation, it is an ideal device for flux measurement.
-
Product
Backlights for Machine Vision
-
Backlighting is one of the most important components of machine vision systems; it must provide the required luminous flux, response speed, area and duration of exposure. Our experience in machine vision systems led us to the need to develop an LED backlight module for flash operation.
-
Product
Dopant
-
In semiconductor manufacturing, electrical performance starts with atomic-level control. Dopant technologies make that possible by introducing carefully measured doping constituents that help devices conduct, switch and perform reliably. For precise control of fluxes for Molecular Beam Epitaxy (MBE) dopant constituents, or for gases that do not require thermal cracking, Veeco’s Dopant products are ideal.
-
Product
Automated Soil CO2 Flux System
LI-8100A
-
A portable, automated system for simple and reliable survey and long-term measurements over a study site. The LI-8100A Analyzer Control Unit contains an infrared gas analyzer and a connection panel to interface with the 8100-103 Survey Chamber, the 8100-104 and 8100-104C Long-Term Chambers, additional gas analyzers, and the LI-8150 Multiplexer.
-
Product
Spectroradiometer
-
Spectroradiometer is usually used with a integrating sphere to measure the photometric and colorimetric parameters of all kinds of lamps. Relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature Tc, color rendering index Ra, dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, SDCM, luminous flux, etc.
-
Product
Advanced Handheld Tachometer
FT-7200
-
The FT-7200 Advanced Tachometer is an easy-to-use handheld digital tachometer offering high functions and performance. The use of FFT (Fast Fourier Transform) technology enables the FT-7200 to perform frequency analysis of rotation speed by using change of signal in sound, vibration or magnetic flux from rotating machines such as a motor or the like. Selection from 5 kinds of measurement modes allows it to calculate and display rotation speed of any complex waveform signals from a sound level meter or an accelerometer accurately by extracting the exact frequency component.
-
Product
LIMES 2000
-
LMT LIMES 2000 software for WINDOWS for measurement and evaluation of light and color distribution or luminous flux with LMT goniophotometers or other photometric instruments
-
Product
5cc Dual Dopant Source
-
Attain precise and stable control of relatively low fluxes for dopant constituents in molecular beam epitaxy (MBE) through this compact dopant source. Its small thermal mass gives it excellent responsiveness, reproducibility, and stabilization for advanced doping profiles, plus consistent flux uniformity across an entire platen. Efficient cell heating minimizes thermal load.
-
Product
Optical Meters
-
The Gamma Scientific range of light meters includes handheld and benchtop models. Configuration options include a wide range of sensors and calibrations in units including: Luminous Flux (lumens) or Radiant Flux (Watts), Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr), Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr), or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.
-
Product
Auxiliary Lamp
RLS-50W
-
Due to the luminaries self-absorption, the auxiliary lamp is used to correct the flux test value. Work with the follow instruments as a System
-
Product
CO2/H2O Analyzer
LI-870
-
The LI-870 CO2/H2O Analyzer is a versatile analyzer for publication quality data that is simple to deploy, use, and maintain. A combination of precision and stability alongside a rugged and fieldable design makes it ideal for survey and long-term research focused on fluxes of soil CO2.
-
Product
Radiometric Probe for UVA Irradiance
LPUVA03…Series
-
The LPUVA03 probe measures irradiance (W/m²) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m²) in the UVA (315 nm…400 nm) spectral range. Thanks to a new type of photodiode, LPUVA03 is blind to visible and infrared light.
-
Product
Probes for Tube Inspection
-
Probes for tube inspection are lightweight but solidly constructed eddy current, remote field, magnetic flux leakage, and IRIS ultrasound. These probes are used for ferromagnetic or non-ferromagnetic tube inspection applications.
-
Product
Irradiance Probe
LPUVC01
-
The LPUVC01 probe measures irradiance (W/m2) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m2) in the UVC (200 nm…280 nm) spectral range.
-
Product
Photometric Probes for Illuminance
LPPHOT03… Series
-
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.
-
Product
Advanced Tachometer
FT-2500
-
FT-2500 advanced tachometer measures the rotational speed by using the signal of change in sound, vibration or magnetic flux from rotating machines such as motor or the like.The use of FFT technology enables the FT-2500 to calculate and display the rotational speed of any complex waveform signals from microphone, sound level meter or vibration sensor by extracting the frequency component which is equivalent to the rotational speed.