High Frequency Probes
-
product
Light-to-Frequency
Light-to-Frequency (LTF) sensors convert measurements of light intensity to a digital form for direct interfacing to a microcontroller. The output of the device is a square wave or pulse stream the frequency of which is linearly proportional to the light intensity. LTF converters are designed for applications such as ambient light measurement, light absorption/reflection in products such as white goods, photographic equipment, colorimetry, chemical analyzers and display contrast controls. They may be used in any system that requires a wide dynamic range, and/or high resolution digital measurement of light intensity.
-
product
SP200B, 200 MHz, ±60 V, 1X or 10X Attenuation, Single-Ended Passive Oscilloscope Probe
780284-01
The SP200B is a standard switchable passive probe for oscilloscopes that provide 1 MΩ input impedance. Depending on the attenuation ratio, the probe has an analog bandwidth of 6 MHz in the 1x attenuation setting or 200 MHz in the 10x attenuation setting.
-
product
LFLT-72 High Performance Lead Free Long Travel Probe
LFLT-72
Current Rating (Amps): 6Average Probe Resistance (mOhm): 100Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 400Full Travel (mm): 10.16Full Travel Remark: High Spring: 350 mil / 8.89 mmRecommended Travel (mil): 317Recommended Travel (mm): 8.05Overall Length (mil): 1,850Overall Length (mm): 46.99
-
product
Frequency Response Analyzers
7400 Series
The Venable Model 7400 Series is the top of the line in Venable performance, supplying 4 channels for increased testing, measurement and analysis functionality. Originally designed for measuring 3-phase impedance and source and load simultaneously, the Model 7400 is a robust solution for organizations requiring high availability for high volume and/or simultaneous testing.
-
product
Shaper Of The Reference Frequency
MFC
The mezzanine module (mezzanine) of the MFC is designed to reproduce on six output lines high-precision frequency values obtained by dividing the frequency from the built-in reference frequency generator.
-
product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39H-5.4
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
product
High 1.50 (43.00) - 9.60 (272.00) Long Travel Bead Probe
BPLT-1F-9.6
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1V-8
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2TB-6
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Frequency Generation & Monitoring
Timetech reference generators, phase comparators, and synchronized oscillators.
-
product
Ultra High 3.83 (109.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-72J-10
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
High Temperature Pitot Probe Protective Cover
This Pitot Probe Cover developed by Nav-Aids Ltd. withstands temperature to 950 degrees F when installed on the pitot tube.With the Nav-Aids Ltd. High Temperature Pitot Probe Cover installed on the pitot tube, and the heat inadvertently activated, there will be : No melting of material No significant residue on the pitot tube No filling of static or drain holes No need to change a pitot probe No cause for aircraft dispatch delay
-
product
Replacement Alligator Clips for High Voltage Differential Probe
PK-HVA-01
Replacement Alligator Clips for High Voltage Differential Probe
-
product
Alternate 2.39 (68.00) - 6.00 (170.00) Bead Probe
BTP-1C-6
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Frequency Calibrator
VCH-313
The frequency calibrator VCH-313 is designed to determine the frequency error and calibrate frequency standards of various types based on the signals of the NSC SNS GLONASS/GPS .
-
product
Passive Frequency Multipliers
The frequency multiplier which generates output with power level less than input power.
-
product
Frequency Ranges
1398A
The useable frequency range is from 5 Hz to more than 10 times higher than that listed in the table below, e.g. T2.5-1 volt and T5-2 volt can be used beyond 10 MHz.
-
product
Frequency Large Display Indicator
Signals & Systems India Private Limited
Large Display indicator measures and displays frequency from the input like supply voltage, 4-20mA and data received from other equipment. It meets high accuracy of 0.1% to measure Frequency. The large display is for clear visibility of the frequency reading from long distance. It is equipped with high bright red color 7segment displays. These are commonly used in Power plants, Substations, Manufacturing units and Field environments to provide direct frequency measurements of various devices.
-
product
Digital Frequency Meter
CSF-400
Measuring frequency. Accuracy: +/- 0.05%. 4 Digital display: 9999 Input Max. 400Hz/600 V, 30KHz/12V. Aux. Power AC 115/230V +/-15%, 50/60Hz. Isolation Aux. Power 12Vdc, 24Vdc, 48Vdc, 110Vdc available in option. Easy-to-wire, screw type terminal. Outside dimensions is DIN standard (96mm x 48mm) High stability & low cost.
-
product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-8
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-9
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
Premium 4.49 (127.00) - 12.00 (340.00) High Performance Lead Free Probe
LFRE-25B-12
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High Frequency Standard Capacitor
GenRad 1403 Series
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.
-
product
Cup Reduced Concave, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0G12-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
Probes
Fujian Lilliput Optoelectronics Technology Co., Ltd.
We are one of the leading and professional probes manufacturers and suppliers in China. Thanks to our highly qualified experts and advanced technology, we are also one of the world's leading brands. Welcome to buy the quality, cheap and durable probes in stock from us. Check the quotation with us now.
-
product
SA2500X, 2.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784257-01
The SA2500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1H-INS-7
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Redundant Frequency and Timing Systems
A unique feature of our frequency standards and distribution amplifiers is that the two separate parts of the redundant system are identical and can easily be inter-changed, for maintenance purposes. What we mean by this is that that we don't have a "Master" unit and a "Slave" unit. Whatever unit is powered up first becomes the master unit and the other becomes the slave unit.
-
product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I15-5.4
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50