DIP LED Aging Tester
LS6100
Designed to measure the aging-life and color comparisons of 260pcs DIP LED. • 260 separate constant current supply • Aging functions: constant current, impact pulse, on-off mode • Range of forward voltage(VF): 5.0V • Range of forward current(IF): 1) constant current: 0-100.0mA 2) Impact pulse: 0-200.0mA • Range of impact pulse frequency: 10-9999Hz; Duty ratio: 1%-99% • Range of on-off circle: 0-9999H59M59S • Range of on-off times: 0-9999times • Range of aging time: 0-9999H59M59S
-
product
DC Electronic Load
M9822/M9822B
M9822/M9822B is newly designed circuit adopts rapid AD and DA technology to achieve rapid measurements with high accuracy. And the resolution of 0.1mV/0.1mA can effectively display the minor change of voltage and current, so the instrument has a wider application field and achieves better test results. Meanwhile your operation becomes much more comfortable and easy by equipping the high-light VFD, the simple menu and displayed contents and the operation state indicators on all keys. Otherwise the complete and humanized test functions will greatly improve your productivity.
-
product
Thermal Sensitive Parameter Selector
UI9600
Parameter measured under normal temperature:1) β (0-99)2) Switching time T (0.01μs-99.9μs), including Tr, Ts, Tf3) VCES (0-2V), VBE (0-2V)4) Leakage current ICEO (0.01μA-99.9mA)5) Withstand voltage BVCEO (50V-650V)• Parameter measured under high temperature: VBE, β, ICEO
-
product
Aging and Optical Attenuation Tester
LS822
• Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.
-
product
Magnetic Shielding Cabinet for EMI Testing
SDR-2000B
Cabinet Shell 2mm galvanized cold-rolled steel sheetCabinet Door 0.9*1.7m(L*W) 0.6*0.6mCabinet Window 0.3*0.3*0.025m(L*W*T) with 4mm hole N/APower Supply Filter 30A/220V 30A/220VInternet Line Filter RJ-45 N/ACabinet Inside Decoration PVC ceiling, PVC plastic steel wall, 10mm wooden + 2mm galvanized steel sheet floorCabinet Inside Size 2*1.2*1.8m 0.8*0.8*0.8mAfter Packing Size 2.2*2.3*2.3m 1*1.1*1.2mAfter Packing Weight 800kg 200kgWorking With EMI-9KA/EMI-9KB EMI-9KA/EMI-9KB, PC, Testing load, and operator inside Testing load is inside to connect with EMI-9KA/EMI-9KB via BNC
-
product
Pocket Color Temperature Meter
CHROMA-1
• Measure Pa rameters: CCT, Chromaticity Coordinate(x, y, u, v) • Display range: 1500K~25000K, Resolution: 1K • Accuracy: 0.5%F.S. • Luminance test function (lx test)
-
product
High and Low Temperature & Low Pressure Chamber
LAP-100
It is according to GB10590 / GB15091 low temperature / low pressure test chamber requirements; GB11159 low pressure test chamber requirements; GB / T2423. 25-1992 low temperature / low pressure integrated chamber requirement; GB / T2423. 26-1992 High temperature / low pressure integrated chamber requirement; GJB150. 2-86 low temperature / low pressure test etc standards. It’s used to test the In aviation, aerospace, information, electronics and other fields, to determine the instrumentation, Electrical products, materials, components, equipment etc.
-
product
Mask ventilation resistance and pressure differential tester
WKS-3102
Mask ventilation resistance and pressure differential tester is used to measure the inhalation and exhalation resistance of mask under specified conditions. Applicable to mask manufacturers, labor protection equipment inspection agencies to carry out related testing and inspection of mask products, mask breath resistance tester, breathing valve air tightness tester, breath resistance machine for measuring respirator and mask protection products in Inspiratory resistance and expiratory resistance under specified conditions.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
LMS-7000CCD Spectroradiometer
LMS-7000
LMS-7000 CCD Spectroradiometer is applied with TOSHIBA TCD1304DG linear array CCD detector, measurement speed is very quick and cost-saving.• The following wavelength range is with 0.8nm FWHM: • Integrating time is 1ms to 60s • CCD Detector is 3648pix which size is 8μm×200mμm • SNR (Signal to Noise Ratio) is 1000: 1 (Full range). A/D is 16bit • Communicate with PC by USB2.0. The software has a rich re-develop platform which can be run in WinXP and Win7. • Optical port is SMA905
-
product
AC Power Source
LSP-500VAR
• AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCU • Protection for over hot, thundering voltage and current • Total voltage distortion: ≤0.3%; Voltage stability: ≤0.05%/30min • Load adjust rate: ≤0.05%; Frequency stability: ≤0.01%/30min • Output voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz, 100Hz, 200Hz and 400Hz • It is pure sine wave AC power source with low harmonic and high accuracy • Input Power: 220V and 50/60Hz (110V can be option) • Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled.
-
product
Multiplex Temperature Tester
TMP-8/TMP-16
• 8 channels temperature signal (TMP-8) or 16 channels temperature signal (TMP-16) • T type or K type thermocouple • Temperature range: -40 ~ 300°C. Testing accuracy: 0.5% • Channel sequence is displayed by 2 LED and temperature is displayed by 4 LED • Freely set up the software with PC and record the change of temperature and select the channel.
-
product
EMI Test System
EMI-9KA
EMI-9KA is an automatic EMI receiver. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KA is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KA fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.
-
product
Masks Flame Retardant Performance Tester
WKS-1208
WKS-1208 Masks Flame Retardant Performance Tester is used to test the burning performance of the mask after contacting the flame at a certain linear velocity. It is special test instrument for the flame retardant performance of masks.
-
product
Electrostatic Discharge Simulator
ESD61000-2
ESD simulator (Electrostatic Discharge Generator or Electrostatic Gun) is in full compliance with IEC 61000-4-2, EN61000-4-2, ISO10605, GB/T17626.2, GB/T17215.301 and GB/T17215.322. The ESD generator is designed for the assessment of electrical and electronic equipment to withstand ESD performance. ESD61000-2/ESD61000-2A has LCD display in both English and Chinese, they equipped with an infrared remote control which can allow you do the test in some special place.